Magno Aparecido Gonçalves Trindade

Magno Aparecido Gonçalves Trindade

Auto-generated profile, based on publicly available information

Magno Aparecido Gonçalves Trindade

Federal University of Grande Dourados

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 March 2013 in Fuel
Verified
Journal Article
Closed access
RCRicardo Pini Caramit
Ricardo Pini Caramit
AAAdriana Garabini de Freitas Andrade
Adriana Garabini de Freitas Andrade
JSJoão Batista Gomes de Souza
João Batista Gomes de Souza
TATatiane Alfonso de Araujo
Tatiane Alfonso de Araujo
LVLuiz Henrique Viana
Luiz Henrique Viana
VFValdir Souza Ferreira
Valdir Souza Ferreira

13 March 2015 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
RCRicardo Pini Caramit
Ricardo Pini Caramit
Antonio S. AraujoAntonio S. Araujo
Antonio S. Araujo
DFDaniela Kárin Fogliatto
Daniela Kárin Fogliatto
LVLuiz Henrique Viana
Luiz Henrique Viana
MTMagno Aparecido Gonçalves Trindade
Magno Aparecido Gonçalves Trindade
VFValdir Souza Ferreira
Valdir Souza Ferreira
The development of electroanalytical methods for determining three or more analytes simultaneously in a complex sample is highly desirable. Unfortunately, this is not an easy task in electrochemical studies of organic compounds, and alternative methods to achieve this goal have been increasingly sought in recent years. To this end, the present investigation employed a combination of screen-printed electrodes (SPEs), cetyltrimethylammonium bromide (CTAB), and a peak deconvolution procedure as an alternative approach to improve the sensitivity and selectivity in the simultaneous determination of three antioxidants in samples of biodiesel and cosmetic oils. The use of CTAB also prevents the occurrence of SPE fouling by matrix constituents, being essential in the simultaneous detection of the antioxidants tert-butylhydroquinone (TBHQ), propyl gallate (PG), and butylhydroxyanisole (BHA). Under optimized conditions, the limit of detection proved satisfactory, with relative standard deviations of 0.99% for TBHQ, 2.1% for PG, and 0.61% for BHA, indicating that the method has satisfactory repeatability. The approach was successfully applied to determine the target antioxidants in biodiesel samples at different concentrations after simple, rapid dilution, yielding recovery rates of 98–106% for TBHQ, 98–103% for PG, and 92–101% for BHA. In the analysis of cosmetic oils, a deconvolution procedure was applied to achieve separation of the oxidation peak potentials, with recovery rates of 94% for PG and 101% for BHA using the standard addition method. The results were satisfactory compared with those obtained using high-performance liquid chromatography.

7 December 2017 in ACS Sustainable Chemistry & Engineering
Verified
Journal Article
Closed access
KGKatia-Emiko Guima
Katia-Emiko Guima
LALeticia M. Alencar
Leticia M. Alencar
GSGabriel C. da Silva
Gabriel C. da Silva
MTMagno A. G. Trindade
Magno A. G. Trindade
CMCauê A. Martins
Cauê A. Martins

1 October 2005 in Microchemical Journal
Verified
Journal Article
Closed access
MTMagno Aparecido G. Trindade
Magno Aparecido G. Trindade
GSGlaucia Maria da Silva
Glaucia Maria da Silva
VFValdir Souza Ferreira
Valdir Souza Ferreira

1 January 2019 in Fuel Processing Technology
Verified
Journal Article
Closed access
JCJosé N. Conceição
José N. Conceição
BMBruno Marangoni
Bruno Marangoni
FMFlávio S. Michels
Flávio S. Michels
IOIvan Oliveira
Ivan Oliveira
WPWilson E. Passos
Wilson E. Passos
Anderson R. L. CairesAnderson R. L. Caires
Anderson R. L. Caires

23 November 2010 in Analytical Letters
Verified
Journal Article
Closed access
MBMichelle Fernanda Brugnera
Michelle Fernanda Brugnera
MTMagno Aparecido Gonçalves Trindade
Magno Aparecido Gonçalves Trindade
MZMaria Valnice Boldrin Zanoni
Maria Valnice Boldrin Zanoni
This work illustrates the effect of cetyltrimethylammonium bromide (CTAB) as an antifouling and pre-concentrating agent for electroanalytical measurement of bisphenol A (BPA) on a screen-printed carbon electrode. The calibration graphs are obtained for BPA from 1.0 × 10−6 to 1.0 × 10−5 mol L−1 in B-R buffer pH 8.0 with addition of CTAB in a ratio of [CTAB]/[BPA] 2:1 and the limit of detection was 5.1 × 10−8 mol L−1. Nonylphenol can be also monitored by SWV at a potential 170 mV more positive than bisphenol A in B-R buffer pH 11.0 in the presence of CTAB. The method was successfully applied for BPA determination in river water and sewage without any pretreatment of the samples.