Sameer Shamshuddin

Sameer Shamshuddin

Auto-generated profile, based on publicly available information

Sameer Shamshuddin

Department of Radiology, University Hospitals of Morecambe Bay NHS Trust, Royal Lancaster Infirmary, Lancaster, UK

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 December 2022 in BMJ
Verified
Journal Article
Open access
PDF file
SSSusan Cheng Shelmerdine
Susan Cheng Shelmerdine
HMHelena Martin
Helena Martin
KSKAPIL SHIRODKAR
KAPIL SHIRODKAR
SSSameer Shamshuddin
Sameer Shamshuddin
JWJonathan Richard Weir-McCall
Jonathan Richard Weir-McCall
Objective To determine whether an artificial intelligence candidate could pass the rapid (radiographic) reporting component of the Fellowship of the Royal College of Radiologists (FRCR) examination. Design Prospective multi-reader diagnostic accuracy study. Setting United Kingdom. Participants One artificial intelligence candidate (Smarturgences, Milvue) and 26 radiologists who had passed the FRCR examination in the preceding 12 months. Main outcome measures Accuracy and pass rate of the artificial intelligence compared with radiologists across 10 mock FRCR rapid reporting examinations (each examination containing 30 radiographs, requiring 90% accuracy rate to pass). Results When non-interpretable images were excluded from the analysis, the artificial intelligence candidate achieved an average overall accuracy of 79.5% (95% confidence interval 74.1% to 84.3%) and passed two of 10 mock FRCR examinations. The average radiologist achieved an average accuracy of 84.8% (76.1-91.9%) and passed four of 10 mock examinations. The sensitivity for the artificial intelligence was 83.6% (95% confidence interval 76.2% to 89.4%) and the specificity was 75.2% (66.7% to 82.5%), compared with summary estimates across all radiologists of 84.1% (81.0% to 87.0%) and 87.3% (85.0% to 89.3%). Across 148/300 radiographs that were correctly interpreted by >90% of radiologists, the artificial intelligence candidate was incorrect in 14/148 (9%). In 20/300 radiographs that most (>50%) radiologists interpreted incorrectly, the artificial intelligence candidate was correct in 10/20 (50%). Most imaging pitfalls related to interpretation of musculoskeletal rather than chest radiographs. Conclusions When special dispensation for the artificial intelligence candidate was provided (that is, exclusion of non-interpretable images), the artificial intelligence candidate was able to pass two of 10 mock examinations. Potential exists for the artificial intelligence candidate to improve its radiographic interpretation skills by focusing on musculoskeletal cases and learning to interpret radiographs of the axial skeleton and abdomen that are currently considered “non-interpretable.”