Alemat Gerezihar Gebregewergs

Alemat Gerezihar Gebregewergs

Auto-generated profile, based on publicly available information

Alemat Gerezihar Gebregewergs


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 March 2026 in Results in Engineering
Verified
Journal Article
Open access
AGAlemat Gerezihar Gebregewergs
Alemat Gerezihar Gebregewergs
Kbrom Tekulu DestaKbrom Tekulu Desta
Kbrom Tekulu Desta
KGKidan Gebreziher Gebregergis
Kidan Gebreziher Gebregergis
KGKibrom Haile Gebrekirstos
Kibrom Haile Gebrekirstos
HDHalefom G. Desta
Halefom G. Desta

20 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
MGMebrahtu Ngusse Gebreyohanss
Mebrahtu Ngusse Gebreyohanss
SMSolomon Teklehaimanot Meresa
Solomon Teklehaimanot Meresa
AGAlem Gebremeskel Gebrezgi
Alem Gebremeskel Gebrezgi
KGKibrom Haile Gebrekirstos
Kibrom Haile Gebrekirstos
KDKbrom Tekulu Desta
Kbrom Tekulu Desta
AGAlemat Gerezihar Gebrejewergs
Alemat Gerezihar Gebrejewergs
The DC-DC boost converter is widely used in power electronic applications requiring voltage step-up operation. However, its output voltage is often affected by overshoot, undershoot, oscillations, and steady-state error, particularly under varying operating conditions. Conventional proportional-integral-derivative (PID) controllers are simple and effective but rely on fixed gains, which may limit their robustness when system parameters change. To address these challenges, this paper proposes a Lyapunov-rule-based Model Reference Adaptive Controller (MRAC) for voltage regulation of a DC-DC boost converter operating in Continuous Conduction Mode (CCM). The proposed controller is developed and evaluated in MATLAB/Simulink and compared with a conventional PID controller using transient and steady-state performance metrics. Simulation results show that the PID controller reduces the uncontrolled overshoot from 67.52% to 7.77% and the settling time from 0.6985 s to 0.277 s. The proposed MRAC further improves performance, achieving an overshoot of 4.60%, a settling time of 0.1458 s, and complete elimination of undershoot. The controller is also tested under input voltage variations, load resistance changes, and measurement disturbances. Unlike the PID controller, the MRAC maintains accurate voltage tracking and stable operation, demonstrating superior robustness and effectiveness in handling nonlinearities and uncertainties in DC-DC boost converters.