John J. Sunderland

John J. Sunderland

Auto-generated profile, based on publicly available information

John J. Sunderland

Department of Radiology, University of Iowa, Iowa City, Iowa

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 March 2017 in European Journal of Nuclear Medicine and Molecular Imaging
Verified
Journal Article
Closed access
PDF file
WFWolfgang P. Fendler
Wolfgang P. Fendler
MEMatthias Eiber
Matthias Eiber
MBMohsen Beheshti
Mohsen Beheshti
JBJamshed Bomanji
Jamshed Bomanji
Francesco CeciFrancesco Ceci
Francesco Ceci
KHKen Herrmann
Ken Herrmann

1 August 2016 in Cell Metabolism
Verified
Journal Article
Closed access
KCKong Chen
Kong Chen
ACAaron M. Cypess
Aaron M. Cypess
MLMaren Laughlin
Maren Laughlin
CHCarol R. Haft
Carol R. Haft
HHHouchun Harry Hu
Houchun Harry Hu
RWRichard L. Wahl
Richard L. Wahl

1 August 1992 in Radiology
Verified
Journal Article
Closed access
NGN C Gupta
N C Gupta
AFA R Frank
A R Frank
NDN A Dewan
N A Dewan
LRL S Redepenning
L S Redepenning
MRM L Rothberg
M L Rothberg
MFM P Frick
M P Frick
It is estimated that nearly one-third of solitary pulmonary nodules (SPNs) may represent bronchogenic carcinoma. The noninvasive imaging methods used currently (ie, plain radiography, computed tomography) are not reliable for accurate detection of malignancy in most SPNs. The authors prospectively evaluated use of positron emission tomography (PET) with 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) for identification of malignancy in 20 patients with noncalcific, radiographically indeterminate SPNs. PET-FDG imaging demonstrated focal hypermetabolism in 13 biopsy-proved malignant nodules, whereas no increased FDG uptake was seen in the seven benign SPNs. Semiquantitative analysis with computation of differential uptake ratios also helped clearly differentiate benign nodules (mean +/- standard deviation, 0.56 +/- 0.27) from malignant nodules (mean +/- standard deviation, 5.63 +/- 2.38) (P less than .001). Thus, PET-FDG imaging may be a potentially useful noninvasive technique for accurate differentiation of benign and malignant SPNs that are radiographically indeterminate.

1 January 2007 in The Journal of Pain
Verified
Journal Article
Closed access
PWPatrick B. Wood
Patrick B. Wood
JPJames C. Patterson
James C. Patterson
JSJohn J. Sunderland
John J. Sunderland
KTKerrie H. Tainter
Kerrie H. Tainter
MGMichael F. Glabus
Michael F. Glabus
DLDavid L. Lilien
David L. Lilien

1 March 1996 in The Journal of Thoracic and Cardiovascular Surgery
Verified
Journal Article
Closed access
WSWalter J. Scott
Walter J. Scott
LGLisa S. Gobar
Lisa S. Gobar
JTJohn D. Terry
John D. Terry
NDNaresh A. Dewan
Naresh A. Dewan
JSJohn J. Sunderland
John J. Sunderland

18 December 2014 in Journal of Nuclear Medicine
Verified
Journal Article
Open access
PDF file
JSJohn J. Sunderland
John J. Sunderland
PCPaul E. Christian
Paul E. Christian
The Clinical Trials Network (CTN) of the Society of Nuclear Medicine and Molecular Imaging (SNMMI) operates a PET/CT phantom imaging program using the CTN’s oncology clinical simulator phantom, designed to validate scanners at sites that wish to participate in oncology clinical trials. Since its inception in 2008, the CTN has collected 406 well-characterized phantom datasets from 237 scanners at 170 imaging sites covering the spectrum of commercially available PET/CT systems. The combined and collated phantom data describe a global profile of quantitative performance and variability of PET/CT data used in both clinical practice and clinical trials. Methods: Individual sites filled and imaged the CTN oncology PET phantom according to detailed instructions. Standard clinical reconstructions were requested and submitted. The phantom itself contains uniform regions suitable for scanner calibration assessment, lung fields, and 6 hot spheric lesions with diameters ranging from 7 to 20 mm at a 4:1 contrast ratio with primary background. The CTN Phantom Imaging Core evaluated the quality of the phantom fill and imaging and measured background standardized uptake values to assess scanner calibration and maximum standardized uptake values of all 6 lesions to review quantitative performance. Scanner make-and-model–specific measurements were pooled and then subdivided by reconstruction to create scanner-specific quantitative profiles. Results: Different makes and models of scanners predictably demonstrated different quantitative performance profiles including, in some cases, small calibration bias. Differences in site-specific reconstruction parameters increased the quantitative variability among similar scanners, with postreconstruction smoothing filters being the most influential parameter. Quantitative assessment of this intrascanner variability over this large collection of phantom data gives, for the first time, estimates of reconstruction variance introduced into trials from allowing trial sites to use their preferred reconstruction methodologies. Predictably, time-of-flight–enabled scanners exhibited less size-based partial-volume bias than non–time-of-flight scanners. Conclusion: The CTN scanner validation experience over the past 5 y has generated a rich, well-curated phantom dataset from which PET/CT make-and-model and reconstruction-dependent quantitative behaviors were characterized for the purposes of understanding and estimating scanner-based variances in clinical trials. These results should make it possible to identify and recommend make-and-model–specific reconstruction strategies to minimize measurement variability in cancer clinical trials.