7 August 2023 in IEEE Access
Millimeter wave (mm-Wave) radar has been widely employed for non-contact vital sign detection. This research proposes a novel processing scheme to improve the accuracy and stability of non-contact heart rate detection. Firstly, we propose an adaptive range bin selection method based on variance which can select accurate range bins containing phase information of vital signs. Secondly, the smooth spline is utilized to fit the original phase signal to obtain a relatively pure template signal. Subsequently, the pure template signal is used as the input signal for the matched filter to convolve with the phase signal. The matched filtering can eliminate interference and noise such as breathing and random body movements (RBM). Next, the heartbeat signal is extracted by the Variable Mode Extraction (VME) algorithm. Finally, a novel frequency measurement technique named as Double-Chirp Z-Transform (Double-CZT) is proposed. The frequency of the heartbeat signal is measured by the Double-CZT. Compared with the traditional frequency measurement techniques, the Double-CZT improves the accuracy of frequency measurement and allows for more accurate heart rate measurements. Many subjects were invited to participate in the experiment, and the mean absolute error (MAE) of heart rate was less than 1 beat per minute (bpm) on average. The experimental results demonstrate that the proposed scheme can improve the signal-to-noise ratio (SNR) of heartbeat signal and provide accurate heart rate estimation.
7 August 2023 in IEEE Access
The technology of non-contact heart rate detection has been proven of great use. However, it is still limited by several challenges, particularly the influence of human motion and random disturbances, which significantly degrade the accuracy of the measurement. To address these challenges, this paper proposes a novel scheme for heart rate detection. Firstly, the proposed scheme utilizes the Multi-Channel Averaging (MCA) technique to improve the signal-to-noise ratio (SNR) of the extracted phase signal from the echoes in the multiple receivers, and a high-pass filter to roughly extract a heartbeat signal. Secondly, to suppress motion artifacts (MA) in the heartbeat signal caused by human motion, the Adaptive Parameter Selection for Expectation-Maximization (APSEM) method is proposed. Further, a novel processing sub-framework which combines the Kalman filtering, the Variational Mode Extraction (VME) algorithm, and the Rife spectral analysis method (called KFRV method) is proposed to mitigate the effect of random disturbances and achieve accurate frequency estimation. Experimental results using the Polar H10 heart rate sensor as a reference show that the proposed scheme achieves accurate heart rate detection in the presence of human motion, with the Mean Absolute Error (MAE) of less than 2.5 beats per minute (bpm), which is much better than traditional schemes. Compared to traditional methods, the proposed scheme exhibits negligible loss in heart rate detection under static state, with an average MAE of 0.99 bpm. Overall, the experimental results demonstrate the applicability of the proposed scheme for accurate heart rate detection in both human motion and static states.
29 October 2022 in European Polymer Journal