Typically, single-lung ex vivo lung perfusion (SL-EVLP) is preferred when there is concern of contamination from the opposite lung. However, a comprehensive assessment of the SL-EVLP has not been completed. The purpose of this study is to compare the physiological parameters of SL-EVLP and double-lung EVLP (DL-EVLP) in the assessment of transplant suitability. Seven pairs of rejected donor lungs were perfused in cellular EVLP, with a tidal volume of 6 ml/kg ideal body weight and a perfusion flow of 70 ml/kg/min. The transplant suitability of each side was judged in the DL-EVLP. Subsequently, the tidal volume and flow were reduced by half. The right SL-EVLP was maintained for 10 min by clamping the left main pulmonary artery and the bronchus. Similarly, left SL-EVLP was performed. The physiological parameters were compared between SL-EVLP and DL-EVLP. PO2/FiO2 ratio was significantly lower in SL-EVLP than in DL-EVLP [182.5 (127.5-309.5) vs 311.5 (257.5-377.0) mmHg, P < 0.001]. There was a significant correlation with a higher shunt fraction and PCO2 in the pulmonary vein in SL-EVLP when compared to DL-EVLP. There was no difference in peak inspiratory and plateau pressures between SL-EVLP and DL-EVLP. Suitable lungs (n = 6) were associated with better PO2/FiO2 ratios and lower airway pressures than non-suitable lungs (n = 8). In SL-EVLP, peak inspiratory and plateau pressures have clinical utility in the assessment of the transplant suitability. It is important that PO2/FiO2 ratio in SL-EVLP is appreciably lower than that in DL-EVLP. This discrepancy should be considered in the evaluation of the transplant suitability in SL-EVLP.
1 December 2019 in The Annals of Thoracic Surgery
1 June 2020 in Journal of Surgical Research
14 February 2018 in Interactive CardioVascular and Thoracic Surgery
We present an innovative method for recruiting clinically rejected donor lungs using positive end-expiratory pressure titration during ex vivo lung perfusion. Currently, ex vivo lung perfusion protocols are using a standard positive end-expiratory pressure of 5 cmH2O for all cases. Individualized positive end-expiratory pressure titration combined with recruitment manoeuvres has been found to significantly improve pulmonary functions in mechanically ventilated patients. Applying this concept to ex vivo lung perfusion may be helpful in increasing the conversion rate for transplant suitability.