Shuolin Li

Shuolin Li

Auto-generated profile, based on publicly available information

Shuolin Li

Science and Technology on Electronic Test and Measurement Laboratory, North University of China, Taiyuan, China

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 April 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
SLShuolin Li
Shuolin Li
LZLei Zhang
Lei Zhang
HXHao Xie
Hao Xie
XYXue Yao
Xue Yao
ZHZhuya Hao
Zhuya Hao
QTQiulin Tan
Qiulin Tan
When an ITO thin-film strain gauge is applied on turbine engine blades, a protective layer must be included to prevent the oxidation of the ITO thin-film sensitive material. In this study, an AlN/Al 2 O 3 composite film is prepared as a protective layer on an alumina ceramic sheet using the pulsed laser deposition technique to cover the ITO-sensitive material film. Subsequently, the films are microscopically characterised, and the high-temperature performance of the ITO thin film strain gauge is verified. The results indicate that the AlN/Al 2 O 3 film is dense and crack-free, and that the ITO thin-film strain gauge with the AlN/Al 2 O 3 film acting as the protective layer demonstrates a minimum resistance temperature coefficient of -521 ppm/°C, minimum resistance drift rate of 0.0117 /h, and good cycle repeatability at 1100 °C when compared to an ITO strain gauge without a protective layer and a strain gauge prepared using a single Al 2 O 3 film protective layer. Furthermore, its strain characteristic test at 800°C showed an average gauge factor (GF) of 8.12.

16 March 2023 in IEEE Sensors Journal
Verified
Journal Article
Closed access
HXHao Xie
Hao Xie
LZLei Zhang
Lei Zhang
XLXiaofen Li
Xiaofen Li
SLShuolin Li
Shuolin Li
ZHZhuya Hao
Zhuya Hao
QTQiulin Tan
Qiulin Tan
Solving heat transfer problems in high-temperature and temperature-changing environments is critical in a variety of applications, including modern turbines, aerospace, and nuclear power plants. However, most current thin-film-type heat flow sensors operate at approximately 1000 °C. Thus, we fabricated a kind of platinum–platinum/rhodium thick-film thermopile-type heat flux sensor which can work stably at 1200 °C based on an alumina ceramic substrate. The entire electrode layer was prepared by screen printing process. The surface morphology of the Pt electrode and the material in thermal resistance layer at different stages were investigated using scanning electron microscopy. The steady-state characteristics of the sensor were evaluated by using a high-temperature test platform. The experiments show that the peak voltage of the sensor is 1.4126 mV at the temperature of 1200 °C and the heat flow density of 283.3 kW/m 2 . Moreover, the repeatability of sensor at 1200 °C and high temperature holding for 4 h experiments were performed, verifying that the sensor has good consistency and durability. Therefore, we infer that the designed sensor can be applied for a long time under high temperature and large heat flow conditions, such as aerospace, mechanical metallurgy and energy construction fields.