Ahmad Saleh

Ahmad Saleh

Auto-generated profile, based on publicly available information

Ahmad Saleh

Peoples’ Friendship University of Russia named after Patrice Lumumba

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 September 2023 in Clinical Dentistry (Russia)
Verified
Journal Article
Open access
PDF file
АХА.м. Хасан
А.м. Хасан
НТН.с. Тутуров
Н.с. Тутуров
СИС.ю. Иванов
С.ю. Иванов
ЕБЕ.а. Булычева
Е.а. Булычева
ДБД.с. Булычева
Д.с. Булычева
АСА. Салех
А. Салех
Уже на протяжении длительного времени в ортодонтии ведется разработка праймеров и бондов с улучшенными адгезивными свойствами для фиксации металлических брекетов к эмали зубов, что особенно важно при работе с боковыми зубами. Цель исследования — сравнение результатов прочности адгезии на сдвиг между отечественным адгезивом V поколения и зарубежного аналога в лабораторных условиях. Исследование проводили на 20 образцах удаленных моляров верхней и нижней челюсти, которые погружали в блоки из акриловой пластмассы. Все образцы были разделены на две группы: в I группе фиксацию металлических брекетов к эмали зубов проводили с применением отечественного набора «Компофикс (Орто)» (ВладМиВа, Россия), во II группе — с использованием зарубежного аналога Enlight (Ormco, США). В I группе показатели адгезии на сдвиг составили 13,21±1,11 МПа, а во II группе — 13,39±1,23 МПа. Среднее значение индекса адгезивных остатков на поверхности брекета в I группе было 18±3%, во II — 15±3%. Результаты исследования показали, что отечественная адгезивная система V поколения не уступает по своим свойствам зарубежному аналогу и рекомендована к использованию в клинической практике врача-ортодонта. For a long time orthodontists has been developing primers and bonds with improved adhesive properties for fixing metal braces to the teeth enamel, which is especially important for lateral teeth. The aim of the study was to compare the results of the shear strength of adhesion between a domestic adhesive system of the V generation and a foreign analogue in laboratory conditions. . The study was carried out using 20 samples of extracted molars of the upper and lower jaws, which were immersed in blocks of acrylic plastic. All samples were divided into two groups: in the group I the fixation of metal braces to the teeth enamel was carried out using a domestic adhesive system Compofix (ortho) (VladMiVa, Russia); in the group II the fixation of metal braces to the teeth enamel was performed using a foreign analogue Enlight (Ormco, USA). . In the group I the value of shear adhesion was 13.21±1.11 MPa, while in the group II — 13.39±1.23 MPa. The average value of the adhesive remant index to the bracket surface was 18±3% in the group I and 15±3% in the group II. . The results of the study showed that the domestic adhesive system of the V generation is not inferior in its properties to a foreign analogue and is recommended for use in the clinical practice in orthodontics.

1 January 2025 in International Journal of Dentistry
Verified
Journal Article
Open access
DADoaa Arnaout
Doaa Arnaout
MAMohamed Altinawi
Mohamed Altinawi
IKimad katbeh
imad katbeh
NTNikolay Tuturov
Nikolay Tuturov
ASAhmad Saleh
Ahmad Saleh
Aim: Behavioral management techniques are not always sufficient, and then it is necessary to use pharmacological management methods. The aim of this study is to compare the effectiveness of buccal midazolam sedation with intranasal midazolam in non‐cooperative children during dental treatment. Materials and Methods: A randomized single blinded comparative clinical study consisted of 40 children aged 3–6 years who were divided randomly into two groups: Group A intranasal midazolam and Group B buccal midazolam. The onset time of action and recovery time from sedation were compared between the two groups, and the efficacy of sedation was evaluated by Houpt behavior scale. The independent student’s T test, Mann–Whitney U test, the Wilcoxon test and the Chi‐square test were used. Results: There were no statistically significant differences in the onset time of action ( p = 0.458) and recovery time from sedation ( p = 0.148). There were no statically significant differences between the two groups in sleeping, crying, and movement categories ( p = 0.747), ( p = 0.183), ( p = 0.732), respectively, or in the overall Houpt scale ( p = 0.393), there were statistically significant differences in the sleep variable between the two studied phases in the intranasal group ( p = 0.014) and in the movement variable in the buccal group ( p = 0.039). Conclusion: Both buccal midazolam and intranasal sedation were effective in the management of uncooperative children during dental treatment at 85% and 80%, respectively. Trial Registration: Australian New Zealand Clinical Trials Registry: ACTRN12624000945527

14 June 2024 in Эндодонтия Today
Verified
Journal Article
Open access
PDF file
HAH. Almokaddam
H. Almokaddam
NTN. S. Tuturov
N. S. Tuturov
IKimad katbeh
imad katbeh
ASA. Saleh
A. Saleh
INTRODUCTION. Over the past decades, there has been significant growth in adhesive technologies for fixed orthodontic appliances. Developments in adhesive systems have focused on simplified methods of use, improved composition and high bonding ability to tooth structure.AIM. The aim of this study is to compare the shear bond strength of a 5th generation adhesive system and a universal adhesive system in two etching techniques for fixation of metal brackets.MATERIALS AND METHODS. The study consisted sample of 30 removed human upper premolars. The teeth were randomly distributed into three groups, 10 in each group. In the group 1, the Transbond XT adhesive system (3M Unitek) was used, in the group 2 – the universal adhesive Tetric N bond Universal (Vivapen) in the etching technique, in the group 3 – Tetric N bond Universal (Vivapen) in the self-etching technique. The study used metal brackets for upper premolars Gemini Bracket MBT (3M Unitek, USA) with a micro-engraved base with an area of 10.61 mm.RESULTS. In group 1, the shear strength value was 21.2 ± 3.2 MPa, in group 2 – 21.6 ± 5.2 MPa, in group 3 – 17.7 ± 6.4 MPa. There were no statistically significant differences between the study groups. According to the study, a decrease in the level of adhesive force was found when using a universal adhesive without prior etching of the enamel with phosphoric acid. However, this level remained within the clinically recommended range.CONCLUSIONS. Thus, all studied adhesive systems used in various etching techniques demonstrated high adhesive performance, providing strong adhesion of the orthodontic structure to the tooth surface.

12 June 2024 in Эндодонтия Today
Verified
Journal Article
Open access
PDF file
HAH. Almokaddam
H. Almokaddam
NTN. S. Tuturov
N. S. Tuturov
IKimad katbeh
imad katbeh
ASA. Saleh
A. Saleh
III. Ibrahim
I. Ibrahim
RELEVANCE. With the advent of nanotechnology, new dental products are being created with the addition of various nanoparticles to improve the quality of the material, as well as increase their durability and antibacterial therapy. Recently, nanoparticles of silver, calcium hydroxyapatite, calcium dioxide, magnesium, cinnamon and vanillin are included in orthodontic adhesives to prevent enamel demineralization during fixed appliance treatment. However, the strength of fixation of the bracket system to the tooth enamel plays an important role in resisting orthodontic and mechanical stress in the oral cavity to achieve precise control of tooth movement.AIM. The purpose of this study is to provide an analytical review of laboratory studies on the shear bond strength of orthodontic adhesives modified with antibacterial nanoparticles.MATERIALS AND METHODS. The eLibrary, PubMed and Google Scholar databases were queried for scientific articles published from 2019 to 2024 using the keywords: nanoparticles, orthodontics, bond strength, orthodontic adhesive, nanoadhesive. Thus, this article included 13 in vitro studies on the topic of shear adhesion strength of nanoadhesives, the remaining 40 scientific articles were devoted to the study of methods of using nanotechnologies in the orthodontic clinic, the properties of various nanoparticles and the problems of demineralization of dental tissue during the correction of dentoalveolar anomalies, their prevention.CONCLUSION. Based on this analysis, it was found that most laboratory studies of orthodontic adhesives containing low concentrations of nanoparticles demonstrated positive antimicrobial potential while maintaining acceptable adhesive bond strength. However, further studies are needed in clinical settings, taking into account humidity and temperature changes in the oral cavity, to achieve the best mechanical performance and antibacterial effectiveness against biofilm-forming pathogens during orthodontic therapy.

19 February 2024 in Stomatologiya
Verified
Journal Article
Closed access
NTN.S. Tuturov
N.S. Tuturov
AKA.M. Khasan
A.M. Khasan
FRF.S. Rusanov
F.S. Rusanov
IKimad katbeh
imad katbeh
DBD.S. Bulycheva
D.S. Bulycheva
ASA. Saleh
A. Saleh
Background. The era of using adhesives to fix brackets began in the 70s of the last century. There are eight generations of foreign-made adhesive systems for the restoration of teeth. However, until now, in orthodontics, the development of domestic adhesive systems with improved properties of adhesion of brackets to tooth enamel still important, especially in the posterior teeth. Objective. The purpose of this work was to study the shear strength of fifth generation domestic adhesive between metal brackets and the enamel of molar teeth in laboratory conditions. Material and methods. The study included 17 specimens of extracted maxillary molars embedded in acrylic resin blocks. Brackets from G&H Orthodontics (G&H Wire Company, USA) were fixed to the tooth enamel using the domestic Compofix (ortho) set. The enamel was treated with etching gel (37% phosphoric acid) for 30 seconds. Then the gel was washed off with water and the surface of the enamel was thoroughly dried. A primer was applied to the prepared surface with an applicator, inflated with a weak air flow for 5—10 seconds and photopolymerized for 20 seconds. The surface of the bracket was treated with degreaser, then a thin layer of adhesive was applied, and the sample was fixed to the enamel. Excess material was removed with an applicator. The samples were photopolymerized for 20 sec. Then, the shear bond strength of the adhesive was determined according to the method of GOST 31574-2012 on a (Zwick/Roell Z010 testing machine, Zwick, Germany). Results. The shear strength of the adhesive joint obtained during the test is 13.54±1.01 MPa, the average value of the index of adhesive residues on the surface of the bracket was 23%±4%, which corresponds to the standard average values according to GOST. Conclusion. The tested domestic adhesive system of the fifth generation can be recommended for the practical work of an orthodontist.

2 April 2026 in Medical alphabet
Verified
Journal Article
Closed access
TKT. F. Kosyreva
T. F. Kosyreva
MAM. A. Al-Okbi
M. A. Al-Okbi
IKimad katbeh
imad katbeh
EGE. Gergos
E. Gergos
ASA. Saleh
A. Saleh
GSG. Saleh
G. Saleh
Introduction: although self-ligating braces are supposed to provide better hygiene conditions, there is still no consensus. The purpose of this study was to evaluate the adhesion of Streptococcus mutans (SM) to self-ligating and ligature braces from various manufacturers and types of ligatures. Methods: two commercial brands of metal braces for upper premolars («Damon 3» Ormco® and «In-Ovation» GAC®) were tested. Each of them was divided into three groups, which differed by the type of ligature (steel and elastomeric) and the model of the bracket (metal, self-ligating), for a total of six groups of six braces each. The pre-sterilized braces were immersed in saliva for one hour, then washed and added to a bacterial suspension kept under aerobic conditions for 72 hours (3 days). The adhering bacteria were then separated and counted by the number of colonies (CFU/mL) after 48 hours of growth. The groups were compared using the Kruskal – Wallis criteria (p <0.05). Results: regardless of the manufacturer’s brand, self-ligating braces showed significantly fewer colonies of microorganisms Cfu/ml. Among the compared models of self-ligating «In-Ovation» braces, GAC® showed the highest level of bacterial adhesion. Conclusions: self-ligating braces are likely to exhibit lower levels of biofilm adhesion compared to ligature braces. This is especially true for «Damon 3» Ormco® braces, which are less prone to biofilm accumulation, which is important to know for practicing orthodontics.