Sujoy Ghosh Hajra

Sujoy Ghosh Hajra

Auto-generated profile, based on publicly available information

Sujoy Ghosh Hajra

Simon Fraser University Surrey BC Canada

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 June 2018 in Journal of Translational Medicine
Verified
Journal Article
Open access
PDF file
SHSujoy Ghosh Hajra
Sujoy Ghosh Hajra
CLCareesa Liu
Careesa Liu
XSXiaowei Song
Xiaowei Song
SFShaun D. Fickling
Shaun D. Fickling
TCTeresa Cheung
Teresa Cheung
RDRyan C.N. D'Arcy
Ryan C.N. D'Arcy
For nearly four decades, the N400 has been an important brainwave marker of semantic processing. It can be recorded non-invasively from the scalp using electrical and/or magnetic sensors, but largely within the restricted domain of research laboratories specialized to run specific N400 experiments. However, there is increasing evidence of significant clinical utility for the N400 in neurological evaluation, particularly at the individual level. To enable clinical applications, we recently reported a rapid evaluation framework known as “brain vital signs” that successfully incorporated the N400 response as one of the core components for cognitive function evaluation. The current study characterized the rapidly evoked N400 response to demonstrate that it shares consistent features with traditional N400 responses acquired in research laboratory settings—thereby enabling its translation into brain vital signs applications. Data were collected from 17 healthy individuals using magnetoencephalography (MEG) and electroencephalography (EEG), with analysis of sensor-level effects as well as evaluation of brain sources. Individual-level N400 responses were classified using machine learning to determine the percentage of participants in whom the response was successfully detected. The N400 response was observed in both M/EEG modalities showing significant differences to incongruent versus congruent condition in the expected time range (p < 0.05). Also as expected, N400-related brain activity was observed in the temporal and inferior frontal cortical regions, with typical left-hemispheric asymmetry. Classification robustly confirmed the N400 effect at the individual level with high accuracy (89%), sensitivity (0.88) and specificity (0.90). The brain vital sign N400 characteristics were highly consistent with features of the previously reported N400 responses acquired using traditional laboratory-based experiments. These results provide important evidence supporting clinical translation of the rapidly acquired N400 response as a potential tool for assessments of higher cognitive functions.

12 May 2016 in Frontiers in Neuroscience
Verified
Journal Article
Open access
SHSujoy Ghosh Hajra
Sujoy Ghosh Hajra
CLCareesa C. Liu
Careesa C. Liu
XSXiaowei Song
Xiaowei Song
SFShaun Fickling
Shaun Fickling
LLLuke E. Liu
Luke E. Liu
RDRyan C.N. D'Arcy
Ryan C.N. D'Arcy
Clinical assessment of brain function relies heavily on indirect behavior-based tests. Unfortunately, behavior-based assessments are subjective and therefore susceptible to several confounding factors. Event-related brain potentials (ERPs), derived from electroencephalography (EEG), are often used to provide objective, physiological measures of brain function. Historically, ERPs have been characterized extensively within research settings, with limited but growing clinical applications. Over the past 20 years, we have developed clinical ERP applications for the evaluation of functional status following serious injury and/or disease. This work has identified an important gap: the need for a clinically accessible framework to evaluate ERP measures. Crucially, this enables baseline measures before brain dysfunction occurs, and might enable the routine collection of brain function metrics in the future much like blood pressure measures today. Here, we propose such a framework for extracting specific ERPs as potential “brain vital signs”. This framework enabled the translation/transformation of complex ERP data into accessible metrics of brain function for wider clinical utilization. To formalize the framework, three essential ERPs were selected as initial indicators: 1) the auditory N100 (Auditory sensation); 2) the auditory oddball P300 (Basic attention); and 3) the auditory speech processing N400 (Cognitive processing). First step validation was conducted on healthy younger and older adults (age range: 22-82 years). Results confirmed specific ERPs at the individual level (86.81%-98.96%), verified predictable age-related differences (P300 latency delays in older adults, p<0.05), and demonstrated successful linear transformation into the proposed brain vital sign (BVS) framework (basic attention latency sub-component of BVS framework reflects delays in older adults, p<0.05). The findings represent an initial critical step in developing, extracting, and characterizing ERPs as vital signs, critical for subsequent evaluation of dysfunction in conditions like concussion and/or dementia.

11 October 2017 in Frontiers in Human Neuroscience
Verified
Journal Article
Open access
CLCareesa C. Liu
Careesa C. Liu
SHSujoy Ghosh Hajra
Sujoy Ghosh Hajra
TCTeresa P. L. Cheung
Teresa P. L. Cheung
XSXiaowei Song
Xiaowei Song
RDRyan C.N. D'Arcy
Ryan C.N. D'Arcy
Spontaneous blinking occurs 15-20 times per minute. Although blinking has often been associated with its physiological role of corneal lubrication, there is now increasing behavioural evidence suggesting that blinks are also modulated by cognitive processes such as attention and information processing. Recent low-density electroencephalography (EEG) studies have reported so-called blink-related oscillations (BROs) associated with spontaneous blinking at rest. Delta-band (0.5-4Hz) BROs are thought to originate from the precuneus region involved in environmental monitoring and awareness, with potential clinical utility in evaluation of disorders of consciousness. However, the neural mechanisms of BROs have not been elucidated. Using magnetoencephalography (MEG), we characterized delta-band BROs in 36 healthy individuals while controlling for background brain activity. Results showed that, compared to pre-blink baseline, delta-band BROs resulted in increased global field power (p<0.001) and time-frequency spectral power (p<0.05) at the sensor level, peaking at approximately 250ms post-blink maximum. Source localization showed that spontaneous blinks activated the bilateral precuneus (p<0.05 FWE), and source activity within the precuneus was also consistent with sensor-space results. Crucially, these effects were only observed in the blink condition and were absent in the control condition, demonstrating that results were due to spontaneous blinks rather than as part of the inherent brain activity. The current study represents the first MEG examination of BROs. Our findings suggest that spontaneous blinks activate the precuneus regions consistent with environmental monitoring and awareness, and provide important neuroimaging support for the cognitive role of spontaneous blinks.

24 September 2012 in IEEE Transactions on Biomedical Engineering
Verified
Journal Article
Closed access
TBTimothy Bardouille
Timothy Bardouille
SKSantosh V. Krishnamurthy
Santosh V. Krishnamurthy
SHSujoy Ghosh Hajra
Sujoy Ghosh Hajra
RDRyan C. N. D’aRcy
Ryan C. N. D’aRcy
Brain source localization accuracy in magnetoencephalography (MEG) requires accuracy in both digitizing anatomical landmarks and coregistering to anatomical magnetic resonance images (MRI). We compared the source localization accuracy and MEG-MRI coregistration accuracy of two head digitization systems - a laser scanner and the current standard electromagnetic digitization system (Polhemus) - using a calibrated phantom and human data. When compared using the calibrated phantom, surface and source localization accuracy for data acquired with the laser scanner improved over the Polhemus by 141% and 132%, respectively. Laser scan digitization reduced MEG source localization error by 1.38 mm on average. In human participants, a laser scan of the face generated a 1000-fold more points per unit time than the Polhemus head digitization. An automated surface-matching algorithm improved the accuracy of MEG-MRI coregistration over the equivalent manual procedure. Simulations showed that the laser scan coverage could be reduced to an area around the eyes only while maintaining coregistration accuracy, suggesting that acquisition time can be substantially reduced. Our results show that the laser scanner can both reduce setup time and improve localization accuracy, in comparison to the Polhemus digitization system.

1 April 2015 in Journal of Neuroscience Methods
Verified
Journal Article
Closed access
LSLauren Sculthorpe-Petley
Lauren Sculthorpe-Petley
CLCareesa Liu
Careesa Liu
SHSujoy Ghosh Hajra
Sujoy Ghosh Hajra
HPHossein Parvar
Hossein Parvar
JSJason Satel
Jason Satel
RDRyan C.N. D'Arcy
Ryan C.N. D'Arcy

20 June 2012 in Surgical Innovation
Verified
Journal Article
Closed access
DCDavid B. Clarke
David B. Clarke
RDRyan C.N. D’aRcy
Ryan C.N. D’aRcy
SDSebastien Delorme
Sebastien Delorme
DLDenis Laroche
Denis Laroche
GGGuy Godin
Guy Godin
RDRobert DiRaddo
Robert DiRaddo
Background. The overriding importance of patient safety, the complexity of surgical techniques, and the challenges associated with teaching surgical trainees in the operating room are all factors driving the need for innovative surgical simulation technologies. Technical development. Despite these issues, widespread use of virtual reality simulation technology in surgery has not been fully implemented, largely because of the technical complexities in developing clinically relevant and useful models. This article describes the successful use of the NeuroTouch neurosurgical simulator in the resection of a left frontal meningioma. Conclusion. The widespread application of surgical simulation technology has the potential to decrease surgical risk, improve operating room efficiency, and fundamentally change surgical training.