Affiliation Section of Interventional Pulmonology, Division of Thoracic Oncology, Department of Surgical Oncology, Orlando Health Cancer Institute, Orlando, Florida, United States of America
Auto-generated profile, based on publicly available information
Kim Styrvoky
Affiliation Section of Interventional Pulmonology, Division of Thoracic Oncology, Department of Surgical Oncology, Orlando Health Cancer Institute, Orlando, Florida, United States of America
Background: Shape sensing robotic-assisted bronchoscopy (ssRAB) combined with radial endobronchial ultrasound (r-EBUS) and cone beam computed tomography (CBCT) is a newer diagnostic modality for the evaluation of pulmonary lesions. There is limited data describing the radiation dose of CBCT combined with ssRAB. The purpose of this study was to describe the technical factors associated with the use of CBCT combined with ssRAB to biopsy pulmonary lesions. Methods: We conducted a single center, prospective observational study of patients undergoing ssRAB combined with fixed CBCT for the pulmonary lesion biopsy. We report our patient demographics, and pulmonary lesion and procedure characteristics. Results: A total of 241 ssRAB procedures were performed to biopsy 269 pulmonary lesions. The mean lesion size was measured in the following dimensions: anteroposterior (18.0±8.8 mm), transverse (17.2±10.5 mm), and craniocaudal (17.7±10.2 mm). A mean of 1.5±0.7 (median: 1, range: 1–4) CBCT spins were performed. The mean total fluoroscopy time (FT) was 5.6±2.9 minutes. The mean radiation dose of cumulative air kerma (CAK) was 63.5±46.7 mGy and the mean cumulative dose area product (DAP) was 22.6±16.0 Gy·cm2. Diagnostic yield calculated based on results at index bronchoscopy was 85.9%. There was a low rate of complications with 8 pneumothoraces (3.3%), 5 (2.1%) of which required chest tube placement. Conclusions: We describe the use of ssRAB combined with CBCT to biopsy pulmonary lesions as a safe diagnostic modality with relatively low radiation dose that is potentially comparable to other image guided sampling modalities. Bronchoscopists should be cognizant of the radiation use during the procedure for both patient and staff safety.
Cardiopulmonary resuscitation (CPR) in patients with severe acute respiratory syndrome coronavirus-2–associated disease (coronavirus disease 2019) poses a unique challenge to health- care providers due to the risk of viral aerosolization and disease transmission. This has caused some centers to modify existing CPR procedures, limit the duration of CPR, or consider avoiding CPR altogether. In this review, the authors propose a procedure for CPR in the intensive care unit that minimizes the number of personnel in the immediate vicinity of the patient and conserves the use of scarce personal protective equipment. Highlighting the low likelihood of successful resuscitation in high-risk patients may prompt patients to decline CPR. The authors recommend the preemptive placement of central venous lines in high-risk patients with intravenous tubing extensions that allow for medication delivery from outside the patients’ rooms. During CPR, this practice can be used to deliver critical medications without delay. The use of a mechanical compression system for CPR further reduces the risk of infectious exposure to health- care providers. Extracorporeal membrane oxygenation should be reserved for patients with few comorbidities and a single failing organ system. Reliable teleconferencing tools are essential to facilitate communication between providers inside and outside the patients' rooms. General principles regarding the ethics and peri-resuscitative management of coronavirus 2019 patients also are discussed.
1 January 2024 in Therapeutic Advances in Respiratory Disease
Background: Incidental and screen-detected pulmonary nodules are common. The increasing capabilities of advanced diagnostic bronchoscopy will increase bronchoscopists’ procedural volume necessitating optimization of procedural scheduling and workflow. Objectives: The objectives of this study were to determine total time in the procedure room, total bronchoscopy procedure time, and robotic-assisted bronchoscopy procedure time longitudinally and per specific procedure performed. Design: A single-center observational study of all consecutive patients undergoing shape-sensing robotic-assisted bronchoscopy (RAB) biopsy procedures for the evaluation of pulmonary lesions with variable probability for malignancy. Methods: Chart review to collect patient demographics, lesion characteristics, and procedural specifics. Descriptive and comparative statistics are reported. Results: Actual bronchoscopy procedure time may decrease with increased institutional experience over time, however, there is limited ability to reduce non-bronchoscopy related time within the procedure room. The use of cone beam computed tomography (CBCT), rapid on-site evaluation (ROSE), and performance of staging endobronchial ultrasound transbronchial needle aspiration (EBUS-TBNA) in a single procedure are each associated with additional time requirements. Conclusion: Institutional procedural block times should adapt to the nature of advanced diagnostic bronchoscopy procedures to allow for the accommodation of new modalities such as RAB combined with other technologies including radial endobronchial ultrasound, CBCT, ROSE, and staging linear EBUS. Identifying institutional median procedural times may assist in scheduling and ideal block time utilization.