Carolin Ivette Rocabruno Valdés

Carolin Ivette Rocabruno Valdés

Auto-generated profile, based on publicly available information

Carolin Ivette Rocabruno Valdés

Universidad Autónoma del Estado de Morelos

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2015 in Fuel
Verified
Journal Article
Closed access
CRC.I. Rocabruno-Valdés
C.I. Rocabruno-Valdés
LRL.F. Ramírez-Verduzco
L.F. Ramírez-Verduzco
JHJ.A. Hernández
J.A. Hernández

1 September 2019 in Renewable Energy
Verified
Journal Article
Closed access
CRC.I. Rocabruno-Valdés
C.I. Rocabruno-Valdés
JGJ.G. González-Rodriguez
J.G. González-Rodriguez
YDY. Díaz-Blanco
Y. Díaz-Blanco
AJA.U. Juantorena
A.U. Juantorena
JMJ.A. Muñoz-Ledo
J.A. Muñoz-Ledo
J. A. HernándezJ. A. Hernández
J. A. Hernández

17 February 2018 in Corrosion Engineering, Science and Technology: The International Journal of Corrosion Processes and Corrosion Control
Verified
Journal Article
Closed access
CRC. I. Rocabruno-Valdés
C. I. Rocabruno-Valdés
JHJ. A. Hernández
J. A. Hernández
AJA. U. Juantorena
A. U. Juantorena
EAE. G. Arenas
E. G. Arenas
RLR. Lopez-Sesenes
R. Lopez-Sesenes
JGJ.G. Gonzalez-Rodriguez
J.G. Gonzalez-Rodriguez
The corrosion behaviour of pure Al, Cu, 1018 carbon steel and 304 type stainless steel in Canola biodiesel during 528 hours has been evaluated by using electrochemical techniques. Techniques include open circuit potentials (OCP), electrochemical noise (EN) and electrochemical impedance spectroscopy (EIS) measurements at room temperature. These tests were complemented by scanning electronic microscopy, X-ray diffraction, infrared spectroscopy and gas mass chromatography analysis. Results have shown that carbon steel had the highest corrosion rate whereas Cu had the lowest corrosion rate. EN measurements indicated that 304 type stainless steel was moderately susceptible to pitting corrosion, whereas the rest of the metals were susceptible to either mixed or uniform type of corrosion. This was due to the degradation of the biodiesel as observed in an increase in its density, viscosity, acidity and water content at the end of the test.

22 October 2020 in Energies
Verified
Journal Article
Open access
PDF file
ABAlfredo Brito-Franco
Alfredo Brito-Franco
JCJorge Uruchurtu chavarin
Jorge Uruchurtu chavarin
IRIsai Rosales-Cadena
Isai Rosales-Cadena
RSRoy Lopez Sesenes
Roy Lopez Sesenes
SSSergio Serna
Sergio Serna
JGJ.G. Gonzalez-Rodriguez
J.G. Gonzalez-Rodriguez
The corrosion behavior of pure aluminum (Al) in 20 v/v% ethanol–gasoline blends has been studied using electrochemical techniques. Ethanol was obtained from different fruits including sugar cane, oranges, apples, or mangos, whereas other techniques included lineal polarization resistance, electrochemical noise, and electrochemical impedance spectroscopy for 90 days. Results have shown that corrosion rates for Al in all the blends were higher than that obtained in gasoline. In addition, the highest corrosion rate was obtained in the blend containing ethanol obtained from sugar cane. The corrosion process was under charge transfer control in all blends; however, for some exposure times, it was under the adsorption/desorption control of an intermediate compound. Al was susceptible to a localized, plotting type of corrosion in all blends, but they were bigger in size and in number in the blend containing ethanol obtained from sugar cane.

13 November 2019 in International Journal of Civil Engineering
Verified
Journal Article
Closed access
PDF file
YBYohandry Díaz Blanco
Yohandry Díaz Blanco
ECElsa Carmina Menchaca Campos
Elsa Carmina Menchaca Campos
CVCarolin Ivette Rocabruno Valdés
Carolin Ivette Rocabruno Valdés
JCJorge Uruchurtu chavarin
Jorge Uruchurtu chavarin

18 September 2021 in Coatings
Verified
Journal Article
Open access
PDF file
NVN. Velazquez-Torres
N. Velazquez-Torres
J. PORCAYO-CALDERONJ. PORCAYO-CALDERON
J. PORCAYO-CALDERON
HMHoracio Martínez-Valencia
Horacio Martínez-Valencia
RSRoy Lopez Sesenes
Roy Lopez Sesenes
IRIsai Rosales-Cadena
Isai Rosales-Cadena
JGJ.G. Gonzalez-Rodriguez
J.G. Gonzalez-Rodriguez
A Ti6Al4V alloy was plasma-oxidized at 600 °C during 1, 2, 3, 5 and 8 h and corroded in an artificial saliva solution. Electrochemical evaluation was performed by using potentiodynamic polarization curves, linear polarization resistance (LPR), and electrochemical impedance spectroscopy (EIS) measurements during 100 h. Corroded specimens were characterized by using Raman spectroscopy and scanning electronic microscopy (SEM). All tests indicated that the highest corrosion resistance was obtained for specimen oxidized during 3 h since the noblest free corrosion potential, lowest passive and corrosion current density values, as well as the highest polarization resistance values were obtained under these circumstances. EIS measurements indicated that the highest impedance and phase angle values obtained for this specimen exhibited a high capacitive behavior typical of a very compact passive film.