Huijuan Xing

Huijuan Xing

Auto-generated profile, based on publicly available information

Huijuan Xing

School of Transportation, NANTONG University, Nantong, China

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 October 2022 in IET Microwaves, Antennas & Propagation
Verified
Journal Article
Open access
HXHuijuan Xing
Huijuan Xing
Yongwei ZhangYongwei Zhang
Yongwei Zhang
YFYanwei Fu
Yanwei Fu
XLXianyang Lv
Xianyang Lv
ZXZhihuo Xu
Zhihuo Xu
AEAhmed El‐Makadema
Ahmed El‐Makadema
Antenna arrays have gained significant interest in millimetre‐wave communication systems as an enabling technology to achieve higher capacity and mitigate the high propagation loss. Such arrays with a large bandwidth need to be efficiently calibrated to maximise their performance. An antenna array calibration method based on a stochastic approximation algorithm and simultaneous perturbation has been developed and the procedures to implement it in both frequency and time domains have been presented. The approaches to define objective functions and establish gradient approximations to fulfill a successful convergence for acquiring calibration coefficients in both domains have been explored. In the time domain implementation, only a fraction of the measurement time was required to calibrate an antenna array of ultrawide bandwidth compared with other methods using a perturbation technique. The effectiveness of the proposed method has been validated via numerical experiments in both domains.

15 March 2023 in IEEE Transactions on Antennas and Propagation
Verified
Journal Article
Open access
Yongwei ZhangYongwei Zhang
Yongwei Zhang
HXHuijuan Xing
Huijuan Xing
XLXianyang Lv
Xianyang Lv
MTMurat Temiz
Murat Temiz
YFYanwei Fu
Yanwei Fu
JGJianjun Gao
Jianjun Gao
Online calibration is desired in antenna arrays of ultrawide bandwidth. This study proposes a time domain calibration method based on the simultaneous perturbation algorithm. Two objective functions were established: power of the received signal at array output; or combination of power and correlation coefficient between the signal at array output and a target signal. For both criteria, the convergence settings require only two measurements at each iteration. One advantage of the method is that the entire signal operation for calibration is performed in the time domain. This is achieved by resolving the effects of distortion on time delay of each channel, which accounts for both amplitude and phase distortions at different frequencies. Therefore, the proposed method significantly increased the calibration efficiency for ultra-wideband antenna arrays. Since time delay coefficients for calibration associated with array elements were determined independently due to characteristic of the simultaneous perturbation, estimation accuracy of the method is tangential to the number of elements in the array, and is mainly dependent on the convergence conditions. This gives the method an additional distinct advantage for calibrating large-scale antenna arrays with ultrawide bandwidth. An estimation accuracy of 99% on time delay adjustments has been achieved and demonstrated.