5 October 2025 in Magnetic Resonance in Medicine
Purpose: The aim of this work is to make the DTI along the perivascular space ( DTI ‐ ALPS ‐index) more robust with respect to region selection and the orientation of the head and fibers. We propose to address this matter by using the principal diffusion directions and an automated, atlas‐based region of interest ( ROI) placement. Methods: Simulations were used to determine the dependence of the DTI ‐ ALPS ‐index on the orientations of the head and nerve fibers. Human MRI was performed on 12 healthy volunteers at 3T using a 64 channel head coil (Cima.X Siemens), and the DTI ‐ ALPS ‐index was calculated along the principal diffusion directions ( ALPS ‐ PAS ) and along the field of view or laboratory frame ( ALPS ‐ LAB ). To calculate the DTI ‐ ALPS ‐index with reduced bias in native space, we developed a novel algorithm for an automatic ROI placement technique. Its calculated index results were compared to those obtained from a manual ROI placement in native space and from an existing atlas‐based ROI placement. Test–retest scans with varying head rotation were conducted for validation. Results: Simulations showed that ALPS ‐ PAS was more robust toward head and fiber rotations than ALPS ‐ LAB . In vivo, ALPS ‐ PAS yielded a 10% higher index than ALPS‐LAB. The automated ROI placement led to a smaller difference in the DTI ‐ ALPS ‐index between test and retest measurement compared to the manual ROI placement. Stability was enhanced with ALPS ‐ PAS for all ROI placements and varying head rotation. Conclusion: Using the principal components of the diffusion and automated ROI selection increased the measured DTI‐ALPS‐index, improved the robustness toward head and fiber orientations and eliminated the need for manual region selection.
13 August 2026 in Magnetic Resonance in Medicine
Purpose: The aim of this work is to investigate if q‐space trajectory imaging (QTI) waveforms can be designed to probe QTI metrics at a single centroid frequency under realistic experimental conditions for in vivo human brain imaging. Methods: Realistic diffusion encoding waveforms based on double‐rotation gradient waveform and magic‐angle spinning of the q‐vector with varying encoding bandwidth, alignment of encoding spectra across encodings (tuning) and across axes (spectral isotropy) were designed to investigate the accuracy of the centroid frequency approximation. QTI metrics were computed for idealized as well as realistic oscillating and pulsed gradient waveforms using analytical diffusion spectra with 1D and 2D short‐range disorder along and perpendicular to axons. For in vivo validation, the waveforms were integrated into a multiband spiral spin‐echo sequence. Results: The simulations demonstrate frequency‐dependent QTI metrics. The combination of tuning and spectral isotropy led to metrics close to the simulated ground‐truth at the centroid frequency of the encoding spectrum. Realistic waveforms with broader bandwidth compared to idealized waveforms introduce little additional error in QTI metrics due to truncation of the cumulant expansion. In agreement with literature, omitting tuning and spectral isotropy reduces isotropic variance and increases microscopic fractional anisotropy when LTE contains lower frequencies, and vice versa for PTE. This observation is confirmed qualitatively by the in vivo measurements. Conclusion: The accuracy of the centroid frequency approximation depends on the combination of encoding spectra and investigated tissue. Using similar encoding spectra for tuning and spectral isotropy leads to metrics, characteristic to the centroid frequency.