1 December 2008 in Journal of Dentistry
1 May 2004 in Journal of Research of the National Institute of Standards and Technology
We have studied a number of effects that can give rise to errors in small-angle measurement systems when they are used to calibrate artifacts such as optical polygons. Of these sources of uncertainty, the most difficult to quantify are errors associated with the measurement of imperfect, non-flat faces of the artifact, causing the instrument to misinterpret the average orientation of the surface. In an attempt to shed some light on these errors, we have compared autocollimator measurements to angle measurements made with a Fizeau phase-shifting interferometer. These two instruments have very different operating principles and implement different definitions of the orientation of a surface, but (surprisingly) we have not yet seen any clear differences between results obtained with the autocollimator and with the interferometer. The interferometer is in some respects an attractive alternative to an autocollimator for small-angle measurement; it implements an unambiguous and robust definition of surface orientation in terms of the tilt of a best-fit plane, and it is easier to quantify likely errors of the interferometer measurements than to evaluate autocollimator uncertainty.
11 July 2023 in Journal of Optics
Spherical surfaces are essential components of optical systems and imaging devices. Moreover, precision spheres are calibration standards for many accurate instruments in dimensional and mass metrology. A spherical surface's main property is its radius of curvature, which can be measured using contact or non-contact methods. Interferometry is an accurate non-contact technique, but some error sources impact it. This study investigates seventeen error sources that affect a laser interferometric system for measuring the radius of curvature of a precision sphere. The measurements are obtained using a Fizeau laser interferometer (GPI-XP, Zygo) with phase-shifting capability and a displacement measuring interferometer (ZMI-1000, Zygo). A silicon–nitride precision sphere with a nominal radius of 12.49965 mm is dealt with in this study. One of the main contributions of this study is proposing three additional error sources: focal shift, optical distortion, and y-axis vibration. Besides, deadpath, nulling, and focal shift error sources contributed 70% of the total uncertainty budget. Also, to correlate measurement accuracy with the reference surface, three transmission spheres (f/3.3, f/1.5, and f/0.65) are employed; f/0.65 reported the most accurate radius measurement of 12.49922 ± 0.00089 mm. This study also investigates the dependence of the nulling error on the coverage factor that defines the tested surface area. The analysis of the measurement uncertainty and the optimum conditions that minimize the system's potential error sources are described in this work.
1 February 2013 in Measurement
25 October 2009 in Optics and Lasers in Engineering