20 August 2018 in RSC Advances
As Lewis acids, boronic acids can bind with 1,2- or 1,3-diols in aqueous solution reversibly and covalently to form five or six cyclic esters, thus resulting in significant fluorescence changes.
26 November 2019 in The Analyst
Herein, boronic acid-based sensors containing two recognition sites were summarized systematically. By two recognition sites working synergistically, the binding affinity and selectivity of sensors improve significantly.
11 May 2020 in Mini-Reviews in Medicinal Chemistry
Paeonol, 2-hydroxy-4-methoxy acetophenone, is one of the main active ingredients of traditional Chinese medicine such as Cynanchum paniculatum, Paeonia suffruticosa Andr and Paeonia lactiflora Pall. Modern medical research has shown that paeonol has a wide range of pharmacological activities. In recent years, a large number of studies have been carried out on the structure modification of paeonol and the mechanism of action of paeonol derivatives has been studied. Some paeonol derivatives exhibit good pharmacological activities in terms of antibacterial, anti-inflammatory, antipyretic analgesic, antioxidant and other pharmacological effects. Herein, the research progress on paeonol derivatives and their pharmacological activities were systematically reviewed.
8 February 2019 in New Journal of Chemistry
Boronic acids have been widely developed as fluorescent sensors for recognition of carbohydrates, especially D-glucose, ions, catechol compounds and so on. However, few D-ribose selective boronic acid sensors have been reported, and their poor water solubility brings a lot of inconvenience to their applications. Herein we report a novel water-soluble sensor, (4-(4-((3-boronobenzamido)propyl)carbamoyl)quinolin-2-yl)boronic acid (sensor 6). The fluorescence of sensor 6 decreased by 50% when combined with 0.0146 M of D-ribose, while it increased when combined with D-mannose, D-galactose, D-fructose, D-glucosamine, sialic acid, D-sorbitol and D-arabinose, and fluorescence change was not obvious after binding to D-glucose. Therefore, this sensor may serve as a fluorescence quenching sensor for D-ribose. By processing the fluorescence binding data using the Benesi–Hildebrand equation, we found that the reciprocal of fluorescence intensity quenching showed a good linear relationship with the reciprocal of D-ribose concentration, indicating that the binding ratio of sensor 6 to D-ribose is 1 : 1. In pH titration experiments, the quenched fluorescence was most pronounced at pH 7.4, indicating that the sensor may serve to recognize D-ribose at physiological pH 7.4. Subsequently, D-ribose can also cause sensor fluorescence quenching in rabbit plasma and the rabbit plasma fluorescence interference can be excluded. These studies indicate that sensor 6 is a promising tool for detecting D-ribose.
3 August 2019 in New Journal of Chemistry
Herein, several boronic acid-based sensors were reported selectively recognizing D-sorbitol in aqueous solution. The fluorescence of sensor 15c was enhanced by 1.5-fold when combined with a low concentration of D-sorbitol (8.88 μM), and the fluorescence enhanced by 0.6-fold after binding to D-fructose, while it did not change obviously when combined with other carbohydrates, including D-arabinose, D-galactose, D-mannose, D-ribose, D-maltose, D-xylose, D-glucose and D-glucosamine. Fluorescence tests were carried out in DMSO/PBS (pH 9, 0.1 M) solution (1 : 99, v/v), at room temperature, which indicated that the sensors are water-soluble. In addition, competition studies showed that sensor 15c works well as a D-sorbitol-specific fluorescence sensor in both the absence and presence of carbohydrate interferents. And sensor 15c has a high binding constant (10 922 ± 776 M−1) and a low limit of detection (6.91 × 10−7 M) at pH 9 among the investigated sensors toward D-sorbitol. Furthermore, sensor 15c was applied to the analysis of real samples (D-sorbitol for oral administration). These studies indicated that sensor 15c may serve as a potential tool to detect the content of D-sorbitol in drugs and food products.
28 June 2019 in RSC Advances
Boronic acid provides faster fluorescence response to Fe3+ compared to other reported sensors, which is critical for continuous dynamic detection.