Francisco Assis de Oliveira Nascimento

Francisco Assis de Oliveira Nascimento

Auto-generated profile, based on publicly available information

Francisco Assis de Oliveira Nascimento

Universidade de Brasília

Research Focus & Metrics

Academic Career Length

25Years (2002-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
11 August 2017 in IEEE Transactions on Power Delivery
Verified
Journal Article
Closed access
KSK. M. Silva
K. M. Silva
FNF. A. O. Nascimento
F. A. O. Nascimento
In this paper, new modifications of the conventional full-cycle and half-cycle discrete Fourier transform (DFT)-based phasor estimation algorithms are proposed. The key idea is to combine two consecutive outputs of their real and imaginary part filters to eliminate the harmful effect of the decaying dc components on phasor estimation, thereby a new strategy to estimate the exponential term is also reported. The proposed algorithms are compared with other DFT-based algorithms by using both computer-simulated and alternative transients program-generated signals. The obtained results reveal that proposed algorithms present excellent results, even taking into account multiple decaying dc components.

1 October 2003
Verified
Conference Paper
Closed access
JCJ.L.A. de Carvalho
J.L.A. de Carvalho
ARAdson Ferreira da Rocha
Adson Ferreira da Rocha
FNF.A. de Oliveira Nascimento
F.A. de Oliveira Nascimento
JNJ.S. Neto
J.S. Neto
LJL.F. Junqueira
L.F. Junqueira

22 March 2006 in Physiological Measurement
Verified
Journal Article
Closed access
PBPedro de A Berger
Pedro de A Berger
FNFrancisco A de O Nascimento
Francisco A de O Nascimento
JCJake C Do Carmo
Jake C Do Carmo
ARAdson Ferreira da Rocha
Adson Ferreira da Rocha
This paper presents a hybrid adaptive algorithm for the compression of surface electromyographic (S-EMG) signals recorded during isometric and/or isotonic contractions. This technique is useful for minimizing data storage and transmission requirements for applications where multiple channels with high bandwidth data are digitized, such as telemedicine applications. The compression algorithm proposed in this work uses a discrete wavelet transform for spectral decomposition and an intelligent dynamic bit allocation scheme implemented by an approach using the Kohonen layer, which improves the bit allocation for sections of the S-EMG with different characteristics. Finally, data and overhead information are packed by entropy coding. The results for the compression of isometric EMG signals showed that this algorithm has a better performance than standard wavelet compression algorithms presented in the literature (presenting a decrease of at least 5% in per cent residual difference (PRD) for the same compression ratio), and a performance that is comparable with the performance of algorithms based on an embedded zero-tree wavelet. For isotonic EMG signals, its performance is better than the performance of the algorithms based on embedded zero-tree wavelets (presenting a decrease in PRD of about 3.6% for the same compression ratios, in the useful compression range).

14 December 2017 in IEEE Journal of Biomedical and Health Informatics
Verified
Journal Article
Closed access
VRValdinar de Araujo Rocha
Valdinar de Araujo Rocha
JCJake Carvalho Do Carmo
Jake Carvalho Do Carmo
FNFrancisco Assis de O. Nascimento
Francisco Assis de O. Nascimento
This work addresses a new approach to objectively evaluate muscle fatigue in isometric and dynamic physical exertions using Surface Electromyography (S-EMG). The emphasis of this proposal is to preserve the spectral signature of the muscle fatigue phenomenon while reducing the spatial effects of electrode localization, and decreasing the disparity of results obtained by the same experimental protocol at different times. A cumulated and normalized modeling was sought to make evident the non-stationary characteristics of muscle fatigue that is gradually identified with its inertia and intensity. A metric involving the proposal of temporal, frequency, and time-frequency weighted-cumulated indicators is presented. Results based on real signals are shown for isometric and dynamic experimental protocols. Performance comparison of the various proposed weighted-cumulated indexes are shown and discussed. The presented approach for the objective cumulative evaluation of muscle fatigue with S-EMG signals has shown to be promising.

1 October 2009 in Electric Power Systems Research
Verified
Journal Article
Closed access
DGDiogo C. Garcia
Diogo C. Garcia
AFAnésio L.F. Filho
Anésio L.F. Filho
MOMarco A.G. Oliveira
Marco A.G. Oliveira
OFOnivaldo A. Fernandes
Onivaldo A. Fernandes
FNFrancisco A. Do Nascimento
Francisco A. Do Nascimento

24 November 2015 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
JCJorge Cormane
Jorge Cormane
FNFrancisco Assis de O. Nascimento
Francisco Assis de O. Nascimento
This paper proposes a transform-based compression algorithm for waveforms associated with power quality and transient phenomena in power systems. This method uses the wavelet transform, a dynamic bit allocation in the transform domain through estimation of the spectral shape, as well as entropy coding in order to minimize residual redundancy. Five distinct approaches for estimating the spectral shape are proposed. Four of them are based on analytical models that seek to describe the decreasing behavior of the transformed coefficients: (1) decreasing linear bit allocation shape; (2) decreasing quadratic bit allocation shape; (3) decreasing exponential bit allocation shape; (4) rotated sigmoid bit allocation shape; and (5) the fifth approach-the neural shape estimator (NSE)-is an adaptive model that uses an artificial neural network to map the changes in the spectrum shape. Results with databases of real signals and a performance evaluation using objective measures are reported. The results indicate that the NSE approach outperforms the other proposed solutions that use spectral shape estimation for coding, as well as other compression contributions reported in the literature.