It is known that the transfer function H(z) of the desired digital infinite-impulse response filter can be obtained from the normalized transfer function H/sub a/(s) of the analog low-pass filter. Recently it has been shown that Pascal matrix allows the appropriate transformation for design of the low-pass, high-pass, and bandpass digital filters. Unfortunately, this method is difficult to use in case of transforming H/sub a/(s) to the high-order bandpass filter. This letter proposes a similar method, especially suitable for design of the bandpass and bandstop filters without order limitation. The presented design algorithm is illustrated by a numerical example.
27 June 2006 in Analog Integrated Circuits and Signal Processing
In this paper we present the noise analysis of an SC filter for RF sampling and downconversion. The filter implementation is made in 0.12mum CMOS and is primarily intended for WLAN in the 2.4 GHz band and with 20 MHz signal bandwidth. The fundamental noise properties of switched capacitor circuits are discussed while deriving the necessary equations needed for the filter noise calculation. The influence of amplifier noise is also discussed, and a technique to remove low-frequency noise and DC offset from the amplifiers is presented. Finally, a noise estimation of a complete RF sampling front-end is made. Our results are verified by simulations using Cadence Spectre RF simulations
Nowadays, in the age of technological development in various areas of life there is a growing interest in non-invasive techniques useful in medical examination. Angiology also called vascular medicine is a medical specialty with interest of diseases and disabilities of the human circulatory system. This domain uses different types of imaging. The acquired images are used for research, diagnostic, therapeutic or educational purposes. Different wavelengths and frequencies are used in the design of medical apparatus. In this paper the usability of near infrared light imaging is discussed and case studies of medical examinations are presented. There is a new approach with range area of applications in angiology.
The modification of the weighted least squares (WLS) method for IIR filter design based on [5] is presented in the paper. The new algorithm allows to obtain quasi-equiripple approximation of the desired frequency response function in the passband and least squares (LS) approximation in the stopband. Even though the proposed method is very simple, it enables to obtain a larger passband-to-stopband ratio (PSR) of energies and a smaller passband ripple of the designed filter magnitude response when compared with the peak-constrained least-squares method.