In impedance cytometry, particle trajectory can influence the measurements obtained. In this review, the physical grounds of this dependence are explained and both the challenges and the opportunities induced by this phenomenon are discussed.
28 January 2022 in IEEE/ASME Transactions on Mechatronics
Untethered small-scale robots can be potentially used in medical applications, such as minimally invasive surgeries and targeted drug delivery. This article introduces a new localization method using electrical impedance tomography, which is an emerging medical imaging technique, to dynamically track small-scale robots. The proposed approach provides the electrical conductivity distribution within the robot workspace from a set of electrical stimulations and voltage measurements gathered from eight electrodes placed at its boundary. The position of the robot can be deduced from the conductivity map that is reconstructed with the contrast in electrical properties between the robot and the background medium. This method is experimentally validated by successfully tracking the 2-D motion of four different magnetically actuated robots within a cylindrical arena (30 mm in diameter and 4.2 mm high). The smallest detected robot is 1.5 × 1.5 × 1 mm 3 . The proposed tracking method provides a noninvasive technology with low-cost and high-speed potential that would be significant and useful for the position feedback control of untethered devices for biomedical applications in the future.
The emergence of miniaturized medical robots capable of performing targeted therapeutic procedures in deep-seated anatomical regions presents an alternative to conventional medical treatments. However, it remains a significant challenge to accurately locate the miniaturized robots in the complex environments of living organisms. Taking advantage of the short wavelength and noninvasive nature, microwave sensing holds promise in detecting small foreign objects embedded in tissue based on their dielectric properties. However, the limiting factor is the trade-off between the penetration depth and the wavelength of the microwave signals. In this study, we investigate the feasibility of using microwave signals in the frequency range from 18 GHz to 40 GHz to detect centimeter to millimeter-scale metallic objects behind tissue-mimicking gelatin screens. The insights obtained from this work pave the way for the development of novel strategies for the localization of miniaturized medical robots using microwaves.
In this study, we present and analyze a deep learning framework designed to achieve real-time particle localization from successive electrical impedance measurements with a limited training dataset.