Susana Y. Kimura

Susana Y. Kimura

Auto-generated profile, based on publicly available information

Susana Y. Kimura

University of Calgary

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2019 in Water Research
Verified
Journal Article
Open access
SKSusana Y. Kimura
Susana Y. Kimura
ACAmy A. Cuthbertson
Amy A. Cuthbertson
JBJonathan D. Byer
Jonathan D. Byer
SRSusan D. Richardson
Susan D. Richardson
Disinfected drinking water contains hundreds of disinfection by-products (DBPs) that are formed by the reaction of disinfectants with natural and anthropogenic organic matter, bromide, and iodide. Understanding what these DBPs are is important because millions of people worldwide consume drinking water every day, and human epidemiologic studies have reported cancer, miscarriage, and birth defects from consuming such waters. While more than 600 DBPs are reported in the literature, very few studies quantify complete classes of chlorinated, brominated, and iodinated DBPs. Also, very few studies conduct comprehensive non-target analyses of unknown DBPs to characterize the complete DBP exposure (the exposome). We developed a new gas chromatography (GC)-mass spectrometry (MS) method that simultaneously quantifies 39 priority unregulated DBPs from six different chemical classes (haloacetaldehydes, haloketones, haloacetamides, haloacetonitriles, halonitromethanes, and iodinated-trihalomethanes) and analyzes unknown DBPs with mass accuracy <600 ppm under full-scan conditions. Using a new type of time-of-flight (TOF) mass spectrometer, which combines selected ion monitoring (SIM)-level sensitivity with mass accuracy of ±0.05 Da, method detection limits of 3-61 ng/L were achieved. These levels were found to be quite comparable to those of a widely used single quadrupole mass spectrometer (2-90 ng/L) operated in SIM mode. However, analysis using this TOF mass spectrometer offers two additional advantages over traditional quadrupole-MS: (1) full-scan data, which provides additional confidence for target analytes, as well as complete mass spectra for unknown analysis, and (2) two decimal place mass accuracy, which allows additional confidence for target analytes and importantly, molecular formula indication for unknowns. High resolution accurate mass TOF was also used to validate identification of selected compounds. This new method was demonstrated on finished drinking waters from three different drinking water plants, where target quantification and non-target unknown analyses were performed simultaneously during the same run. This enabled the quantification of 39 DBPs, along with the non-target identification of many other drinking water contaminants, including two additional non-target DBPs: N,N-dimethylacetamide and N-nitrosodibutylamine.

1 April 2020 in Water Research
Verified
Journal Article
Closed access
ACAmy A. Cuthbertson
Amy A. Cuthbertson
SKSusana Y. Kimura
Susana Y. Kimura
HLHannah K. Liberatore
Hannah K. Liberatore
DKDetlef R.U. Knappe
Detlef R.U. Knappe
BSBenjamin Stanford
Benjamin Stanford
SRSusan D. Richardson
Susan D. Richardson

1 April 2022 in Environmental Research
Verified
Journal Article
Closed access
SGSunantha Ganesan
Sunantha Ganesan
TRThanaporn Ruendee
Thanaporn Ruendee
SKSusana Y. Kimura
Susana Y. Kimura
CCChamorn Chawengkijwanich
Chamorn Chawengkijwanich
DJDao Janjaroen
Dao Janjaroen

SPShahid Parvez
Shahid Parvez
JAJeffrey Ashby
Jeffrey Ashby
SKSusana Y. Kimura
Susana Y. Kimura
SRSusan D. Richardson
Susan D. Richardson
Disinfected water is the major source of haloacetic acids (HAAs) in humans, but their inter- and intra-individual variability for exposure and risk assessment applications is under-researched. Thus, we measured HAAs in cross-sectional and longitudinal urine and water specimens from 17 individuals. Five regulated HAAs—mono-, di-, and trichloroacetic acid (MCAA, DCAA, and TCAA) and mono- and dibromoacetic acid (MBAA and DBAA)—and one unregulated HAA—bromochloroacetic acid (BCAA)—were measured. Urinary DCAA, MBAA, DBAA, and BCAA levels were always below the limits of detection (LOD). Measured levels and interindividual variability of urinary MCAA were higher than urinary TCAA. Longitudinal urinary specimens showed MCAA levels peaked in after-shower specimens, while TCAA levels remain unchanged. Correlation between urinary MCAA and TCAA was moderate but statistically significant. The prevalence of MCAA and TCAA in urine suggest they can be considered as biomarkers of HAA. Peak urinary MCAA in post-shower specimens suggest MCAA captures short-term exposure via dermal and/or inhalation, while urinary TCAA captures long-term exposure via ingestion. However, further research is warranted in a large pool of participants to test the reliability of MCAA as exposure biomarker.

1 April 2020 in Journal of Hazardous Materials
Verified
Journal Article
Closed access
YSYewen Shi
Yewen Shi
WMWuren Ma
Wuren Ma
FHFengchan Han
Fengchan Han
YGYan Geng
Yan Geng
XYXia Yu
Xia Yu
XJXiaodong Jia
Xiaodong Jia

1 September 2019 in Journal of Chromatography A
Verified
Journal Article
Closed access
FHFengchan Han
Fengchan Han
YGYudong Gao
Yudong Gao
FHFen Hu
Fen Hu
XYXia Yu
Xia Yu
HXHuijian Xie
Huijian Xie
Weiwei ZhengWeiwei Zheng
Weiwei Zheng