Allan Clark Gutierrez Leiva

Allan Clark Gutierrez Leiva

Auto-generated profile, based on publicly available information

Allan Clark Gutierrez Leiva

Faculty of Dentistry, Universidad Nacional Mayor de San Marcos (UNMSM), Lima, Peru

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 May 2020 in Odontología Sanmarquina
Verified
Journal Article
Open access
PDF file
AGAllan Gutierrez-Leiva
Allan Gutierrez-Leiva
CPCésar Pomacóndor-Hernández
César Pomacóndor-Hernández
Objective. To compare the depth of cure of three bulk-fill resin composites using polywave vs. monowave LED light-curing units. Methods. Cylindrical specimens (4 mm diameter and 10 mm height) were prepared using resin composites: Filtek One Bulk Fill Restorative (FO) (3M ESPE), Tetric N-Ceram Bulk Fill (TNC) (Ivoclar Vivadent) and Opus Bulk Fill APS (OP) (FGM), to evaluate the depth of cure according to ISO 4049 standard (n = 5). Two LED light-curing units were used: Bluephase N (Polywave, Ivoclar Vivadent) and LED D (Monowave, Woodpecker) with 24 J/cm2 of energy density. Data were analyzed by two-way Analysis of Variance and Tukey's post hoc test (α = 5%). Results. LED D group showed higher depth of cure values in all resin composites evaluated (p < 0.05). The values were: Bluephase N: 3.87 (TNC) > 3.74 (FO) > 3.31 (OP), and LED D: 4.29 (TNC) > 4.11 (FO) > 3.92 (OP). Conclusions. The monowave LED light-curing unit produced greater depth of cure than the polywave, regardless of the bulk-fill resin composite used. Resin composites showed different depth of cure values. Objetivo. Comparar la profundidad de polimerización de tres resinas compuestas bulk fill obtenida con dos unidades de fotoactivación LED (polywave versus monowave). Métodos. Con las resinas compuestas bulk fill: Filtek One Bulk Fill Restorative (FO) (3M ESPE), Tetric N-Ceram Bulk Fill (TNC) (Ivoclar Vivadent) y Opus Bulk Fill APS (OP) (FGM), fueron confeccionados cuerpos de prueba (n = 5) de formato cilíndrico (4 mm diámetro y 10 mm altura) para la evaluación de la profundidad de polimerización según la norma ISO 4049. Fueron empleadas dos unidades de fotoactivación LED de diferentes tecnologías: Bluephase N (Tecnología Polywave - Ivoclar Vivadent) y LED D (Tecnología Monowave - Woodpecker) con densidad de energía de 24 J/cm2. Los datos fueron analizados por medio del análisis de la varianza de dos factores y la prueba post hoc de Tukey (α = 5%). Resultados. LED D produjo mayores valores de profundidad de polimerización en todas las resinas compuestas bulk fill evaluadas (p < 0,05). Los valores obtenidos con Bluephase N fueron: 3,87 (TNC) > 3,74 (FO) > 3,31 (OP) y con LED D fueron 4,29 (TNC) > 4,11 (FO) > 3,92 (OP). Conclusiones. La unidad de fotoactivación LED de tecnología monowave produjo mayor profundidad de polimerización que la de tecnología polywave, independientemente de la resina compuesta bulk fill utilizada. Las resinas compuestas tuvieron diferentes valores de profundidad de polimerización.

16 May 2026 in Photodiagnosis and Photodynamic Therapy
Verified
Journal Article
Open access
ALAna Claudia Hilda Cullash Luza
Ana Claudia Hilda Cullash Luza
MSMaría Elena Salazar-Salvatierra
María Elena Salazar-Salvatierra
SMSilvia Celestina Luza Montero
Silvia Celestina Luza Montero
JYJavier Enrique Castro Yanahida
Javier Enrique Castro Yanahida
ALAllan Clark Gutierrez Leiva
Allan Clark Gutierrez Leiva
JCJorge Raúl Colchado Carhuavilca
Jorge Raúl Colchado Carhuavilca
Enterococcus faecalis is associated with persistent endodontic infections due to its ability to form resistant biofilms. Antimicrobial photodynamic therapy (aPDT) has emerged as a promising alternative approach. This study evaluated the antibiofilm activity of an ethanolic extract of Curcuma longa L. against E. faecalis ATCC 29,212, with and without aPDT. An in vitro biofilm model was used. The minimum biofilm inhibitory concentration (MBIC) was determined. Biofilms were treated with the C. longa extract (7.81-2000 µg/mL) under LED irradiation (aPDT) and without light activation. Chlorhexidine (2%) served as a positive control while untreated biofilms served as negative control. Biofilm biomass was quantified by optical density, and statistical analysis was performed using ANOVA and Tukey's test (p < 0.05). The MBIC was 62.5 µg/mL. aPDT significantly reduced biofilm formation compared to the negative control (p < 0.001). The highest inhibitory effects were observed at 31.25 and 62.5 µg/mL, with effects comparable to those of 2% chlorhexidine under in vitro conditions. The highest concentration (2000 µg/mL) showed reduced activity and a potential paradoxical, concentration-dependent effect. Without light activation, the extract also showed antibiofilm activity, but to a lesser extent. Curcuma longa L. exhibits concentration-dependent antibiofilm activity against E. faecalis, enhanced by aPDT. Reduced efficacy at higher concentrations may be related to aggregation and self-quenching of curcumin. Despite chlorhexidine remaining the clinical reference, C. longa showed comparable effects at optimal concentrations. Limitations include the absence of a light-only control, lack of CFU confirmation, and potential staining risk.