Namkee Oh

Namkee Oh

Auto-generated profile, based on publicly available information

Namkee Oh

Department of Surgery, Samsung Medical Centre, Sungkyunkwan University School of Medicine , Seoul

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Annals of Surgical Treatment and Research
Verified
Journal Article
Open access
PDF file
NONamkee Oh
Namkee Oh
GCGyu-Seong Choi
Gyu-Seong Choi
WLWoo Young Lee
Woo Young Lee
Oh N, et al. Ann Surg Treat Res. 2023 May;104(5):269-273. https://doi.org/10.4174/astr.2023.104.5.269

20 November 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
JSJunhyuk Seo
Junhyuk Seo
DCDasol Choi
Dasol Choi
TKTaerim Kim
Taerim Kim
WCWon Chul Cha
Won Chul Cha
MKMinha Kim
Minha Kim
ECEdward Choi
Edward Choi
Background: The advancement of large language models (LLMs) offers significant opportunities for health care, particularly in the generation of medical documentation. However, challenges related to ensuring the accuracy and reliability of LLM outputs, coupled with the absence of established quality standards, have raised concerns about their clinical application. Objective: This study aimed to develop and validate an evaluation framework for assessing the accuracy and clinical applicability of LLM-generated emergency department (ED) records, aiming to enhance artificial intelligence integration in health care documentation. Methods: We organized the Healthcare Prompt-a-thon, a competitive event designed to explore the capabilities of LLMs in generating accurate medical records. The event involved 52 participants who generated 33 initial ED records using HyperCLOVA X, a Korean-specialized LLM. We applied a dual evaluation approach. First, clinical evaluation: 4 medical professionals evaluated the records using a 5-point Likert scale across 5 criteria—appropriateness, accuracy, structure/format, conciseness, and clinical validity. Second, quantitative evaluation: We developed a framework to categorize and count errors in the LLM outputs, identifying 7 key error types. Statistical methods, including Pearson correlation and intraclass correlation coefficients (ICC), were used to assess consistency and agreement among evaluators. Results: The clinical evaluation demonstrated strong interrater reliability, with ICC values ranging from 0.653 to 0.887 (P<.001), and a test-retest reliability Pearson correlation coefficient of 0.776 (P<.001). Quantitative analysis revealed that invalid generation errors were the most common, constituting 35.38% of total errors, while structural malformation errors had the most significant negative impact on the clinical evaluation score (Pearson r=–0.654; P<.001). A strong negative correlation was found between the number of quantitative errors and clinical evaluation scores (Pearson r=–0.633; P<.001), indicating that higher error rates corresponded to lower clinical acceptability. Conclusions: Our research provides robust support for the reliability and clinical acceptability of the proposed evaluation framework. It underscores the framework’s potential to mitigate clinical burdens and foster the responsible integration of artificial intelligence technologies in health care, suggesting a promising direction for future research and practical applications in the field.

17 October 2023 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NONamkee Oh
Namkee Oh
JKJae-Hun Kim
Jae-Hun Kim
JRJinsoo Rhu
Jinsoo Rhu
WJWoo Kyoung Jeong
Woo Kyoung Jeong
GCGyu-Seong Choi
Gyu-Seong Choi
JJJae-Won Joh
Jae-Won Joh
Recent advancements in deep learning have facilitated significant progress in medical image analysis. However, there is lack of studies specifically addressing the needs of surgeons in terms of practicality and precision for surgical planning. Accurate understanding of anatomical structures, such as the liver and its intrahepatic structures, is crucial for preoperative planning from a surgeon’s standpoint. This study proposes a deep learning model for automatic segmentation of liver parenchyma, vascular and biliary structures, and tumor mass in hepatobiliary phase liver MRI to improve preoperative planning and enhance patient outcomes. A total of 120 adult patients who underwent liver resection due to hepatic mass and had preoperative gadoxetic acid-enhanced MRI were included in the study. A 3D residual U-Net model was developed for automatic segmentation of liver parenchyma, tumor mass, hepatic vein (HV), portal vein (PV), and bile duct (BD). The model’s performance was assessed using Dice similarity coefficient (DSC) by comparing the results with manually delineated structures. The model achieved high accuracy in segmenting liver parenchyma (DSC 0.92 ± 0.03), tumor mass (DSC 0.77 ± 0.21), hepatic vein (DSC 0.70 ± 0.05), portal vein (DSC 0.61 ± 0.03), and bile duct (DSC 0.58 ± 0.15). The study demonstrated the potential of the 3D residual U-Net model to provide a comprehensive understanding of liver anatomy and tumors for preoperative planning, potentially leading to improved surgical outcomes and increased patient safety.

11 January 2024 in International Journal of Surgery
Verified
Journal Article
Open access
NONamkee Oh
Namkee Oh
JKJae-Hun Kim
Jae-Hun Kim
JRJinsoo Rhu
Jinsoo Rhu
WJWoo Kyoung Jeong
Woo Kyoung Jeong
GCGyu-Seong Choi
Gyu-Seong Choi
JJJae-Won Joh
Jae-Won Joh
Background: This study aimed to develop an automated segmentation system for biliary structures using a deep learning model, based on data from magnetic resonance cholangiopancreatography (MRCP). Materials and methods: Living liver donors who underwent MRCP using the gradient and spin echo technique followed by three-dimensional modeling were eligible for this study. A three-dimensional residual U-Net model was implemented for the deep learning process. Data were divided into training and test sets at a 9:1 ratio. Performance was assessed using the dice similarity coefficient to compare the model’s segmentation with the manually labeled ground truth. Results: The study incorporated 250 cases. There was no difference in the baseline characteristics between the train set (n=225) and test set (n=25). The overall mean Dice Similarity Coefficient was 0.80±0.20 between the ground truth and inference result. The qualitative assessment of the model showed relatively high accuracy especially for the common bile duct (88%), common hepatic duct (92%), hilum (96%), right hepatic duct (100%), and left hepatic duct (96%), while the third-order branch of the right hepatic duct (18.2%) showed low accuracy. Conclusion: The developed automated segmentation model for biliary structures, utilizing MRCP data and deep learning techniques, demonstrated robust performance and holds potential for further advancements in automation.

28 September 2024 in Scientific Reports
Verified
Journal Article
Open access
PDF file
NONamkee Oh
Namkee Oh
BKBogeun Kim
Bogeun Kim
TKTaeyoung Kim
Taeyoung Kim
JRJinsoo Rhu
Jinsoo Rhu
JKJongman Kim
Jongman Kim
GCGyu-Seong Choi
Gyu-Seong Choi
Pure laparoscopic donor hepatectomy (PLDH) has become a standard practice for living donor liver transplantation in expert centers. Accurate understanding of biliary structures is crucial during PLDH to minimize the risk of complications. This study aims to develop a deep learning-based segmentation model for real-time identification of biliary structures, assisting surgeons in determining the optimal transection site during PLDH. A single-institution retrospective feasibility analysis was conducted on 30 intraoperative videos of PLDH. All videos were selected for their use of the indocyanine green near-infrared fluorescence technique to identify biliary structure. From the analysis, 10 representative frames were extracted from each video specifically during the bile duct division phase, resulting in 300 frames. These frames underwent pixel-wise annotation to identify biliary structures and the transection site. A segmentation task was then performed using a DeepLabV3+ algorithm, equipped with a ResNet50 encoder, focusing on the bile duct (BD) and anterior wall (AW) for transection. The model’s performance was evaluated using the dice similarity coefficient (DSC). The model predicted biliary structures with a mean DSC of 0.728 ± 0.01 for BD and 0.429 ± 0.06 for AW. Inference was performed at a speed of 15.3 frames per second, demonstrating the feasibility of real-time recognition of anatomical structures during surgery. The deep learning-based semantic segmentation model exhibited promising performance in identifying biliary structures during PLDH. Future studies should focus on validating the clinical utility and generalizability of the model and comparing its efficacy with current gold standard practices to better evaluate its potential clinical applications.

13 June 2024 in International Journal of Surgery
Verified
Journal Article
Open access
NONamkee Oh
Namkee Oh
JKJae-Hun Kim
Jae-Hun Kim
JRJinsoo Rhu
Jinsoo Rhu
WJWoo Kyoung Jeong
Woo Kyoung Jeong
GCGyu-Seong Choi
Gyu-Seong Choi
JJJae-Won Joh
Jae-Won Joh
Background: Precise preoperative assessment of liver vasculature and volume in living donor liver transplantation is essential for donor safety and recipient surgery. Traditional manual segmentation methods are being supplemented by deep learning (DL) models, which may offer more consistent and efficient volumetric evaluations. Methods: This study analyzed living liver donors from Samsung Medical Center using preoperative CT angiography data between April 2022 and February 2023. A DL-based 3D residual U-Net model was developed and trained on segmented CT images to calculate the liver volume and segment vasculature, with its performance compared to traditional manual segmentation by surgeons and actual graft weight. Results: The DL model achieved high concordance with manual methods, exhibiting Dice Similarity Coefficients of 0.94±0.01 for the right lobe and 0.91±0.02 for the left lobe. The liver volume estimates by DL model closely matched those of surgeons, with a mean discrepancy of 9.18 ml, and correlated more strongly with actual graft weights (R-squared value of 0.76 compared to 0.68 for surgeons). Conclusion: The DL model demonstrates potential as a reliable tool for enhancing preoperative planning in liver transplantation, offering consistency and efficiency in volumetric assessment. Further validation is required to establish its generalizability across various clinical settings and imaging protocols.