Lukas Stefanski

Lukas Stefanski

Auto-generated profile, based on publicly available information

Lukas Stefanski

Institute of Electrical Engineering (ETI), Karlsruhe Institute of Technology Electrical Engineering and Information Technology, 226220 Karlsruhe, Baden-Wrttemberg, Germany

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 April 2021 in IEEE Transactions on Power Electronics
Verified
Journal Article
Closed access
DBDaniel Bernet
Daniel Bernet
LSLukas Stefanski
Lukas Stefanski
MHMarc Hiller
Marc Hiller
More demanding harmonic limits of future grid standards are likely to aggravate the disadvantages associated with the use of passive filters in high-power converters. For this reason, active filters are an increasingly attractive alternative for reducing converter-induced harmonics, however their performance is often subject to a limited frequency range and a frequency-dependent attenuation. To further improve the potential of active filters for use with grid-connected power converters, this paper presents a novel control scheme for a parallel voltage-source active filter integrated into a high-power main converter. A detailed converter analysis shows that, due to the advantageous converter configuration, the active filter requires only fundamental frequency current control to mitigate converter-induced current harmonics. In contrast to conventional active filter applications, this avoids tuning to specific frequencies, identification of individual harmonics, measurement of high-frequency current ripple and high control bandwidth. As shown by simulation results, the active filter thus allows the mitigation of harmonics up to frequencies above the switching frequency of the main converter at only a small share of the total power and with small passive components. Finally, the effectiveness of the presented control scheme is verified experimentally using a silicon carbide demonstrator.

1 September 2019
Verified
Conference Paper
Open access
RSRudiger Schwendemann
Rudiger Schwendemann
MLMarkus Lorcher
Markus Lorcher
FSFabian Sommer
Fabian Sommer
LSLukas Stefanski
Lukas Stefanski
MHMarc Hiller
Marc Hiller

1 September 2018
Verified
Conference Paper
Closed access
DBDaniel Bernet
Daniel Bernet
LSLukas Stefanski
Lukas Stefanski
RSRudiger Schwendemann
Rudiger Schwendemann
CRChristoph Rollbuhler
Christoph Rollbuhler
MHMarc Hiller
Marc Hiller
Low- and medium voltage power converters for grid applications require bulky and expensive LCL-filters in order to meet the harmonic limits defined by the grid code. This paper presents a novel hybrid converter topology with smaller passive components, composed of a high power main converter with an integrated low power active filter. The presented coupled control strategies for a current-source and a voltage-source topology enable the immediate mitigation of the switching frequency current ripple, significantly decreasing the total harmonic distortion (THD) of the output current to below 0.5% and thereby eliminating the need for a passive LCL-filter. Compared to LCL-filter based converter systems, a reduction of the inductive component expenditure of up to 50% is achievable even for a very low active filter to main converter power rating ratio of 10%. The outstanding harmonic performance and reduced passive component demand of the hybrid converter allow increased power density and efficiency as well as lower costs of low- and medium voltage power converters.

1 May 2019
Verified
Conference Paper
Open access
CRC. Rollbuhler
C. Rollbuhler
LSL. Stefanski
L. Stefanski
SGS. Gretzinger
S. Gretzinger
JKJ. Kolb
J. Kolb
MHMarc Hiller
Marc Hiller
MDMartin Doppelbauer
Martin Doppelbauer
Current distortion of two-level converter-fed permanent magnet synchronous machines causes additional machine-side losses, which lead to a distinct reduction in the drive train efficiency of electric vehicles for instance. Determining these losses by measurement is still an ambitious task. On the one hand, there's a lack of adequate voltage sources. On the other hand, there is no accurate procedure to distinguish between the different loss components. In this publication, a 100 kVA seven-level multilevel converter is used to determine the losses of a 60 kW highly-utilized permanent magnet synchronous machine for automotive use. Due to the good voltage quality of the multilevel converter, the machine currents have very low harmonic distortion and the determined losses are considered as fundamental ones. In a second experiment, the machine is operated with a conventional two-level converter. Comparing machine losses in both experiments allows the determination of the additional machine losses in two-level operation.