Luciana Pereira da Silva

Luciana Pereira da Silva

Auto-generated profile, based on publicly available information

Luciana Pereira da Silva

Department of Pediatric Dentistry and Orthodontics, School of Dentistry Federal University of Rio de Janeiro Rio de Janeiro RJ Brazil

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2023 in Pesquisa Brasileira em Odontopediatria e Clínica Integrada
Verified
Journal Article
Open access
LSLuciana Pereira da Silva
Luciana Pereira da Silva
LBLuan Ferreira Bastos
Luan Ferreira Bastos
CMClara Silva Avellar Mascarenhas
Clara Silva Avellar Mascarenhas
Ricardo Tadeu LopesRicardo Tadeu Lopes
Ricardo Tadeu Lopes
MAMichelle Mikhael Ammari
Michelle Mikhael Ammari
ANAline de Almeida Neves
Aline de Almeida Neves

4 September 2024 in Brazilian Journal of Oral Sciences
Verified
Journal Article
Open access
PDF file
PSPedro Américo Felizardo dos Santos
Pedro Américo Felizardo dos Santos
VAVanessa Moreira Andrade
Vanessa Moreira Andrade
LBLuan Ferreira Bastos
Luan Ferreira Bastos
LSLuciana Pereira Da Silva
Luciana Pereira Da Silva
Ricardo Tadeu LopesRicardo Tadeu Lopes
Ricardo Tadeu Lopes
MVMaria Augusta Visconti
Maria Augusta Visconti
Aim: To determine new energy parameters in micro-CT to allow appropriate segmentation of dental cementum from the surrounding structures. Methods: For this pilot study, 11 single-rooted premolar teeth of young subjects aged 12 to 21 were selected. The teeth were scanned using high-energy microtomography (SkyScan 1173, Bruker) with varying acquisition energies (60, 70, and 80 kV). Each tooth was scanned three times. The images were reconstructed and analyzed by calculating the volume (mm³) of dental cementum in the cervical, middle, and apical root thirds among the different scanned stacks. The mean cementum volume in the root thirds was obtained, and correlated with the patient’s age, using Pearson’s correlation. Results: The mean age of the patients in the sample was 16,73 years. For the 60kV energy, the cementum volumes were 1.01 mm³, 1.00 mm³, and 0.58 mm³, for the cervical, middle, and apical thirds, respectively. For 70kV, it was 1.08 mm3, 1.20 mm3, and 0.71 mm3 for the respective thirds. And for 80kV, 0.55 mm3, 0.91 mm3, and 0.67 mm3 for the respective thirds. Conclusion: An acquisition energy of 70kV resulted in the best segmentation and reproducibility of the results. Micro-CT can be a useful tool to non-destructively evaluate the dental cementum.

19 March 2026 in International Journal of Dental Hygiene
Verified
Journal Article
Open access
LSLuciana Pereira da Silva
Luciana Pereira da Silva
FSFernanda Mafei Felix da Silva
Fernanda Mafei Felix da Silva
MMMarcela Baraúna Magno
Marcela Baraúna Magno
DFDaniele Masterson Tavares Pereira Ferreira
Daniele Masterson Tavares Pereira Ferreira
ACAmanda Cunha Regal de Castro
Amanda Cunha Regal de Castro
ANAline de Almeida Neves
Aline de Almeida Neves
Objective: To pare the detection of carious lesions involving orthodontic appliances (O) with the fluorescent method (I) and visual clinical examination (R) in patients treated with fixed orthodontics (P). Methods: Five databases and grey literature were searched until January 2023. Clinical studies, comparing at least one digital fluorescent method (DFM) with visual clinical examination (VCE), in patients who completed treatment with fixed orthodontic appliances, were eligible. After extracting the data, the risk of bias and the certainty of the evidence were evaluated through the QUADAS‐2 and the GRADE approaches, respectively. Results: Five cross‐sectional studies were included in the final synthesis. The number of teeth evaluated ranged from 137 to 1653. Quantification of lesion severity by determining fluorescence loss was a great benefit compared to the qualitative data obtained by VCE. The average loss of fluorescence, measured by quantitative light‐induced fluorescence (QLF) method, in the lesions visually detected was 12.6%, in some areas greater than 15%. The correlation between DIAGNODent and VCE scores ranged from 0.40 to 0.71. The studies were judged at risk of bias with very low certainty of evidence on the comparison between DFMs and VCE. Conclusion: The detection of non‐cavitated carious lesions by DFMs showed a similar pattern to the VCE, although the former detected more lesions than the latter, which encourages the use of these technologies for early detection in patients submitted to fixed orthodontic treatment. Clinical Relevance: The clinical advantage of using the DFMs include the more objective diagnosis, and that measurements can be displayed to the patients and may, therefore, have a pedagogical value. In contrast, they are more time consuming clinically and pose an extra cost; however, it is believed that rapid technology innovation may reduce these costs.