Natural Flood Management (NFM) is receiving much attention in the United Kingdom and across Europe and is now widely seen as a valid solution to help sustainably manage flood risk whilst offering significant multiple benefits. However, there is little empirical evidence demonstrating the effectiveness of NFM interventions in reducing flood hazard at the catchment scale. The Belford Burn catchment (~6km2) in Northern England provides a focus for this article, and utilises observed data collected throughout the NFM project's monitoring period (2007–2012). This study discusses the introduction of catchment‐wide water storage through the implementation of runoff attenuation features (RAFs), in‐particular offline storage areas, as a means of mitigating peak flow magnitudes in flood‐causing events. A novel experimental monitoring setup is introduced alongside an analytical approach to quantify the impact of individual offline storage areas, which has demonstrated local reductions in peak flow for low magnitude storm events. Finally, a physically based model has been created to demonstrate the impact of a network of offline storage areas to enable assessment of storage thresholds required to mitigate design storm events, thus enabling design of an NFM scheme. The modelling results have shown that peak flow can be reduced by more than 30% at downstream receptors.
Flooding is one of the major risks in the UK, which is increasing due to climate change and increased urbanisation. The Environment Agency in the UK has predicted that 1 in 4 properties will be affected by flood risk due to river, sea or surface water flooding by 2050. Traditional flood defences built to protect the receptors such as infrastructure and people in floodplain are facing more intense and frequent floods. Natural Flood Management (NFM) aims to reduce flood risk to downstream communities by implementing upland measures that slow and store runoff, complementing traditional flood defences. Field-based evidence of the effectiveness of different types of NFM features are limited. This research develops a field-based method to quantify the performance of offline runoff attenuation ponds. A dense hydrometric network comprising of 12 pressure transducers, 2 ultrasound flow probes, and a tipping-bucket rain gauge has been installed across the site Coatham Beck, NE England (April 2024–present). The study quantifies pond storage and evaluates reduction or delay in downstream peak flows. This study addresses the wider challenge of lack of empirical quantification on NFM features. Findings will inform the design consideration for building better offline ponds allowing the replicability of such measures of flood in wider scale mitigating the impact of future flood risk.