Non-intrusive load monitoring (NILM) techniques are based on the analysis of load energy signatures. With characterizing associated transient energy signature, the reliability and accuracy of recognition results can be accurately understood or ascertained. In this study, the computer supported cooperative work techniques (CSCW), artificial neural networks (ANN), in combination with turn-on transient energy analysis, are used to identify loads and to improve recognition accuracy and computational speed of NILM results. The experimental results indicated that the incorporation of turn-on transient energy signature analysis into NILM revealed more information than traditional NILM methods, and the resulting recognition accuracy and computational speed were improved. In addition, in combination with computer supported cooperative work in electromagnetic transient program (EMTP) simulation, calculations of turn-on transient energy facilitated load identification that had significant effect on NILM results.
This paper proposes to compare the performance of neural network classifiers between back propagation (BP) and learning vector quantization (LVQ) for pattern analyses of features selection in a non-intrusive load monitoring (NILM) system. Load recognition for identifying loads being connected and disconnected is applied to a NILM by using a neural network, especially for industrial electrical loads, even though some loads are activated at the nearly same time. In order to accurately decompose the aggregate load into its components, a feature-based model for describing the signatures of individual appliances and load combinations is used. The model will suggest the certain signatures which can be detected for all loads in order to indicate the activities of the separate components. To verify the performance of the model for the features selection, the data sets of the electrical loads and the load recognition techniques apply an electromagnetic transient program (EMTP) and a neural network, respectively. The effectiveness and computation equipment of load recognition are analyzed and compared by using the back propagation classifier and the learning vector quantization classifier. To obtain a maximum recognition accuracy rate, the calculation of the turn-on transient energy signature employs a window of samples, Δt, to adaptively segment a transient representative of a class of loads. Experiments performed with a variety of model data sets which reveal the back propagation classifier is superior to the learning quantization classifier in the effectiveness and computation equipment of load recognition.
This paper proposes the use of power signature to recognize different loads with the same real power and reactive power in a non-intrusive load-monitoring (NILM) system. To test the performance of the proposed approach, the data sets for electrical loads were analyzed and established using an electromagnetic transient program (EMTP) and onsite load measurement. Load recognition techniques were applied in a neural network. The effectiveness of load recognition and the time requirement were analyzed and compared using a back propagation classifier method. The experiments revealed that analyzing the turn-on transient energy signatures can enhance the efficiency of load recognition, particularly for different loads with the same real power and reactive power in a NILM system, and improve ability of computational speed.
This paper proposes that artificial intelligence techniques and non-intrusive energy-managing technology (NIEM) will effectively manage energy demands within economic dispatch strategy analysis for the cogeneration plant and power utility. To test the performance of the proposed approach, data sets for electrical loads in the factories were analyzed and established using an electromagnetic transient program (EMTP) and onsite load measurement. The artificial intelligence techniques were applied to data extraction and factory load identification, especially for non-intrusive energy management. The effectiveness of factory load identification was analyzed and compared using different classifier methods. The strategy analysis revealed that the analysis of economic dispatch strategy for the cogeneration plant and power utility in the way of energy demands using the NIEM can estimate reasonably energy contribution from the cogeneration plant and/or power utility, and further improve air pollution. The application of artificial intelligence can reduce greatly the computation time and the size of memory for factory load identification and energy calculation.
In response to the governmental policy of saving energy sources and reducing CO2, and carry out the resident quality of local; this paper proposes a new method for a non-intrusive energy management (NIEM) system in smart home to implement the load identification of electric equipments and establish the electric demand management. Non-intrusive energy management techniques were often based on power signatures in the past, these techniques are necessary to be improved for the results of reliability and accuracy of recognition. By using neural network (NN) in combination with genetic programming (GP) and turn-on transient energy analysis, this study attempts to identify load demands and improve recognition accuracy of non-intrusive energy-managing results. The turn-on transient energy signature can improve the efficiency of load identification and computational time under multiple operations.