Elena Alexandrovna Matveeva

Elena Alexandrovna Matveeva

Auto-generated profile, based on publicly available information

Elena Alexandrovna Matveeva

Federal Budgetary Institution of Science “Scientific Research Institute of Disinfectology” of the Federal Service on Surveillance for Consumer Rights Protection and Human Well-being; Federal State Budgetary Educational Institution of Further Professional Education Russian Medical Academy of Continuing Professional Education of the Ministry of Healthcare of the Russian Federation

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 September 2020 in Disinfection affairs
Verified
Journal Article
Closed access
ASAnton Yuryevich Skopin
Anton Yuryevich Skopin
SWScientific Research Disinfectology Institute of Federal Service for Surveillance on Consumer Rights Protection and Human Well-being
Scientific Research Disinfectology Institute of Federal Service for Surveillance on Consumer Rights Protection and Human Well-being
EMElena Alexandrovna Matveeva
Elena Alexandrovna Matveeva
FMFedor Alexandrovich Mukabenov
Fedor Alexandrovich Mukabenov
IUI.M. Sechenov First Moscow State Medical University (Sechenov University)
I.M. Sechenov First Moscow State Medical University (Sechenov University)
Dezinfektsionnoe delo, Disinfection affairs

15 December 2019 in Hygiene and sanitation
Verified
Journal Article
Open access
ASA. Yu. Skopin
A. Yu. Skopin
TGT. V. Gololobova
T. V. Gololobova
EMElena A. Matveeva
Elena A. Matveeva
AIA. O. Ivanova
A. O. Ivanova
Introduction. Low quality of endoscope treatment is one of the main risk factors for HAI during endoscopic manipulations. Special equipment is widely used to increase quality and safety of healthcare during the treatment of flexible endoscope. However, to confirm the efficiency of such equipment it is necessary to carry out laboratory experimental studies. Material and methods. A prototype model of domestically developed Device intended for carrying out the stages of final cleaning and high-level disinfection (HLD) of flexible endoscopes was used during research, utilizing the samples of agents with various active ingredients. Flexible endoscopes were used as testing devices. Donor blood was utilized for imitation of organic contamination. Mycobacterium terrae test microorganism culture was used for artificial contamination of testing devices. Results. As a result of studying the efficiency of final cleaning and HLD of flexible endoscopes in the Device after them being used once, negative azopyram samples were identified in all endoscope swabs; also, no growth of test microorganism was registered. During the studies of HLD efficiency in case of multiple use of functional solutions treatment efficiency was registered for 6-8 cycles. After the 12th treatment cycle characteristic growth of test microorganism is observed in the swabs. Efficiency of endoscopes’ decontamination in case of multiple use of a disinfectant based on peroxyacetic acid was confirmed during a work shift after 8 cycles; the decrease of disinfecting agent (DA) concentration by more than 10 times was registered during the shelf life of the functional solution on day 5. Conclusions. Studies indicate the necessity to research the efficiency of devices’ use to determine the conditions ensuring efficiency and safety of healthcare during endoscopic interventions.