1 December 2012 in Cardiology in the Young
IAI. Ricardo Argueta-Morales
I. Ricardo Argueta-Morales
Computational fluid dynamics has been applied to the design, refinement, and assessment of surgical procedures and medical devices. This tool calculates flow patterns and pressure changes within a virtual model of the cardiovascular system. In the field of paediatric cardiac surgery, computational fluid dynamics is being used to elucidate the optimal approach to staged reconstruction of specific defects and study the haemodynamics of the resulting anatomical configurations after reconstructive or palliative surgery. In this paper, we review the techniques and principal findings of computational fluid dynamics studies as applied to a few representative forms of congenital heart disease.
1 July 1997 in Numerical Heat Transfer, Part B: Fundamentals
A generalized boundary integral equation (BIE) is formulated for heat conduction problems in anisotropic media with spatially varying thermal conductivities arising from material heterogeneity. The generalized integral equation is expressed in terms of contour integrals only. This is accomplished with the aid of a generalized fundamental solution E and with the definition of a singular nonsymmetric generalized forcing function, D. Generalized fundamental solutions, E, are derived as locally radially symmetric responses to this nonsymmetric singular forcing function, D. Both E and D are defined in terms of the thermal conductivity of the medium. Although it is locally radially symmetric about the source point, E varies within the domain as the source point changes position. Examples of generalized fundamental solutions are provided for various thermal conductivities along with the corresponding forcing function, D. Numerical implementation is discussed. Numerical results are provided for several examples with spatially variable thermal conductivity in isotropic, orthotropic, and fully anisotropic heterogeneous media. Problems ore solved in 2-D and 3-D regular and irregular regions with single- and multiply-connected domains. Close agreement found between the generalized BIE solution and exact solutions validates the formulation developed in this article.
9 January 2023 in Microscopy and Microanalysis
This work describes cryogenic ex situ lift out (cryo-EXLO) of cryogenic focused ion beam (cryo-FIB) thinned specimens for analysis by cryogenic transmission electron microscopy (cryo-TEM). Steps and apparatus necessary for cryo-EXLO are described. Methods designed to limit ice contamination include use of an anti-frost lid, a vacuum transfer assembly, and a cryostat. Cryo-EXLO is performed in a cryostat with the cryo-shuttle holder positioned in the cryogenic vapor phase above the surface of liquid N2 (LN2) using an EXLO manipulation station installed inside a glove box maintained at < 10% relative humidity and inert (e.g., N2 gas) conditions. Thermal modeling shows that a cryo-EXLO specimen will remain vitreous within its FIB trench indefinitely while LN2 is continuously supplied. Once the LN2 is cut off, modeling shows that the EXLO specimen will remain vitreous for over 4 min, allowing sufficient time for the cryo-transfer steps which take only seconds to perform. Cryo-EXLO was applied successfully to cryo-FIB-milled specimen preparation of a polymer sample and plunge-frozen yeast cells. Cryo-TEM of both the polymer and the yeast shows minimal ice contamination with the yeast specimen maintaining its vitreous phase, illustrating the potential of cryo-EXLO for cryo-FIB-EM of beam-sensitive, liquid, or biological materials.
1 December 2000 in Engineering Analysis with Boundary Elements