Ki-Tek Han

Ki-Tek Han

Auto-generated profile, based on publicly available information

Ki-Tek Han

School of Biomedical Engineering, College of Biomedical & Health Science, Research Institute of Biomedical Engineering, Konkuk University, 322 Danwol-dong, Chungju-si, Chungcheongbuk-do, 380-701, Korea

Research Focus & Metrics

Academic Career Length

16Years (2011-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 May 2012 in Sensors
Verified
Journal Article
Open access
PDF file
WYWook Jae Yoo
Wook Jae Yoo
JMJinsoo Moon
Jinsoo Moon
KJKyoung Won Jang
Kyoung Won Jang
KHKi-Tek Han
Ki-Tek Han
SSSang Hun Shin
Sang Hun Shin
BLBongsoo Lee
Bongsoo Lee
A T-shaped fiber-optic phantom-dosimeter system was developed using square scintillating optical fibers, a lens system, and a CMOS image camera. Images of scintillating light were used to simultaneously measure the transverse and longitudinal distributions of absorbed dose of a 6 MV photon beam with field sizes of 1 × 1 and 3 × 3 cm2. Each optical fiber has a very small sensitive volume and the sensitive material is water equivalent. This allows the measurements of cross-beam profile as well as the percentage depth dose of small field sizes. In the case of transverse dose distribution, the measured beam profiles were gradually become uneven and the beam edge had a gentle slope with increasing depth of the PMMA phantom. In addition, the maximum dose values of longitudinal dose distribution for 6 MV photon beam with field sizes of 1 × 1 and 3 × 3 cm2 were found to be at a depth of approximately 15 mm and the percentage depth dose of both field sizes were nearly in agreement at the skin dose level. Based on the results of this study, it is anticipated that an all-in-one phantom-dosimeter can be developed to accurately measure beam profiles and dose distribution in a small irradiation fields prior to carrying out stereotactic radiosurgery.

11 October 2011 in Sensors
Verified
Journal Article
Open access
PDF file
WYWook Jae Yoo
Wook Jae Yoo
KJKyoung Won Jang
Kyoung Won Jang
JSJeong Ki Seo
Jeong Ki Seo
JMJinsoo Moon
Jinsoo Moon
KHKi-Tek Han
Ki-Tek Han
BLBongsoo Lee
Bongsoo Lee
A 2-channel embedded infrared fiber-optic temperature sensor was fabricated using two identical silver halide optical fibers for accurate thermometry without complicated calibration processes. In this study, we measured the output voltages of signal and reference probes according to temperature variation over a temperature range from 25 to 225 °C. To decide the temperature of the water, the difference between the amounts of infrared radiation emitted from the two temperature sensing probes was measured. The response time and the reproducibility of the fiber-optic temperature sensor were also obtained. Thermometry with the proposed sensor is immune to changes if parameters such as offset voltage, ambient temperature, and emissivity of any warm object. In particular, the temperature sensing probe with silver halide optical fibers can withstand a high temperature/pressure and water-chemistry environment. It is expected that the proposed sensor can be further developed to accurately monitor temperature in harsh environments.