Xiang Wu

Xiang Wu

Auto-generated profile, based on publicly available information

Xiang Wu

College of Control Science and Engineering, China University of Petroleum (East China), Qingdao, China

Research Focus & Metrics

Academic Career Length

3Years (2024-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 July 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
XWXiang Wu
Xiang Wu
YGYanfeng Geng
Yanfeng Geng
MLMingLei Li
MingLei Li
WWWeiliang Wang
Weiliang Wang
MTMengyu Tu
Mengyu Tu
Inter-turn short circuit (ITSC) fault is the most common and harmful fault of permanent magnet synchronous motor (PMSM). Preventing from subsequent severe damage to the motor and related systems, detection of ITSC becomes an important issue. In order to detect the ITSC problem efficiently and accurately, particularly when fault data is scarce, this paper proposes an effective method, which can eliminate redundant information and extract valuable features of the ITSC current signal of PMSM using a data processing method. Subsequently, Pearson coefficient optimized Wasserstein generative adversarial network (PWGAN) is dsigned to generate fault data and filter out low-quality data to construct a hierarchical training strategy, which allows siamese convolutional neural network (SCNN) have better detection of ITSC problem in the case of a small size of fault samples and reduces substantial computational burden. Due to large number of healthy data being put into model in actual use, a soft threshold method is adopted to pre-classify most of healthy data to improve stability of diagnosis system. Experimental test is performed to substantiate that the hierarchically trained model, when furnished with a substantial number of fault samples, is capable of achieving an accuracy rate of 98.75%. In comparison to other machine learning methodologies, SCNN demonstrates superior accuracy, particularly in scenarios where ITSC fault data is limited. The application of the soft threshold method allows for the preliminary diagnosis of up to 94.7% of healthy data inputs, thereby enabling the overall diagnostic system to attain an accuracy rate of 98.97%.

25 December 2024 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
XWXiang Wu
Xiang Wu
MLMinglei Li
Minglei Li
YGYanfeng Geng
Yanfeng Geng
HQHaiyu Qian
Haiyu Qian
The operational efficiency of a permanent magnet synchronous motor (PMSM) is intrinsically linked to its stability, making the accurate diagnosis of common faults such as inter-turn short circuits (ITSC) crucial. ITSC can cause significant damage to the PMSM and its system. Traditional data-driven fault diagnosis methods often require a large amount of expert-labeled data to ensure accuracy, which is challenging to obtain in actual operations. To address this, this paper introduces an unsupervised learning method for ITSC fault diagnosis that extracts inherent data patterns from unlabeled samples. The approach begins with a unique data processing method and the Fast Fourier Transform to handle the original three-phase current data, thereby reducing data complexity. Following this, an unsupervised framework, utilizing Noise-Aware Density based Clustering with Auto-Tuning (NADCAT), is constructed, in which NADCAT provides pseudo-labels for deep neural networks, enabling precise mapping of features to ITSC faults. A PMSM experiment platform was established to validate the method proposed in this paper. The pseudo-labels obtained by proposed NADCAT achieved a 92.8% effective rate, and the diagnostic model attained an accuracy of 97.63%. These results demonstrate the effectiveness of the method proposed in diagnosing ITSC faults of the PMSM.

7 October 2024 in IEEE Sensors Journal
Verified
Journal Article
Closed access
MLMinglei Li
Minglei Li
YGYanfeng Geng
Yanfeng Geng
WWWeiliang Wang
Weiliang Wang
XWXiang Wu
Xiang Wu
QZQingfeng Zeng
Qingfeng Zeng
MTMengyu Tu
Mengyu Tu
In the oil drilling environment, permanent magnet synchronous motors (PMSM) are constantly exposed to high temperatures, strong vibrations, and variable velocity. There is little real-world Inter-turn Short Circuit (ITSC) data from the oil well. These problems lead to most ITSC fault characterization types being invalid and no real-world ITSC data are available for diagnosis neural network model training. To address these challenges, we propose a zero real-world fault training data diagnosis (ZRFTD) framework. In this framework, the diagnosis network is trained by physical fault model data. Initially, the internal physical construction of PMSM-ITSC is modeled to generate trainset data. Secondly, the proposed pre-diagnosis mechanism accurately decides when to start the diagnosis neural network, avoiding unnecessary operation when the PMSM is healthy. And self-adjustment peak-to-peak alignment difference (APAD) method is proposed to extract the ITSC current characteristics stably. Thirdly we constructed a simplified local chunking parallel transformer neural network (SLCPTN) as a fault diagnosis network, greatly reducing computational consumption. Finally, an oil-drilling up-ground experimental platform is established to generate the testset data which are inputted into the trained SLCPTN for ITSC fault level diagnosis to assess the efficacy of ZRFTD. The related theoretical derivation and experimental validation prove the feasibility of the ZRFTD framework and achieve an accuracy of 99.2% in classifying real-world PMSM-ITSC data under an oil-drilling environment.

25 February 2025 in IEEE Transactions on Instrumentation and Measurement
Verified
Journal Article
Closed access
MLMinglei Li
Minglei Li
YGYanfeng Geng
Yanfeng Geng
XWXiang Wu
Xiang Wu
WWWeiliang Wang
Weiliang Wang
XJXin Jin
Xin Jin
GPGuangliang Pan
Guangliang Pan
Deep learning technology based on large-scale labeled data is increasingly used to diagnose permanent magnet synchronous motor (PMSM) inter-turn short circuit (ITSC) faults. However, the presence of small fault samples context and the large amounts of unlabeled data are challenging problems in real-world industrial applications. To address these challenges, we propose an optimized Lipschitz generative network-gradient spectral generative adversarial network (GSGAN) within the semi-supervised mechanism. Then, we incorporate the graph attention mechanism to achieve accurate fault severity diagnosis. For the specific, firstly, the GSGAN utilizes gradient and parameter spectral information to strictly enforce the Lipschitz condition of the generative network for generating realisticlike ITSC fault data. Secondly, the semi-supervised mechanism enhanced by a temporal causal sparse fusion graph attention neural network (TCSFGAT) is proposed. The TCSFGAT obtains multi-sample level adjustable fault feature information which can clearly represent the graph features in temporal PMSM current fault information. In addition, TCSFGAT can effectively mitigate the impact of pattern confusion caused by mislabeled pseudo-labels in testset diagnostic process. Finally, based on the real industrial environment characterized by high temperatures and strong vibrations, experiments were conducted under 13 specific load and speed conditions to obtain raw fault data. Experimental results indicate the proposed framework achieves a remarkable 98.7% fault diagnosis accuracy.