Yujun Ji

Yujun Ji

Auto-generated profile, based on publicly available information

Yujun Ji

Hohai University

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 March 2023 in Materials & Design
Verified
Journal Article
Open access
CZChun Zhao
Chun Zhao
GTGangqiang Tang
Gangqiang Tang
YJYujun Ji
Yujun Ji
XZXIN ZHAO
XIN ZHAO
MDMei Dong
Mei Dong
Yanjie WangYanjie Wang
Yanjie Wang

31 January 2023 in Polymers
Verified
Journal Article
Open access
PDF file
CZChun Zhao
Chun Zhao
YJYujun Ji
Yujun Ji
GTGangqiang Tang
Gangqiang Tang
XZXIN ZHAO
XIN ZHAO
DMDong Mei
Dong Mei
Yanjie WangYanjie Wang
Yanjie Wang
Ionic polymer–metal composites (IPMCs) have attracted attention in recent years due to their integration of actuation and sensing functions. As one of the main sensing functions of IPMCs, humidity sensing has been of consistent interest in wearable health monitors and artificial skin. However, there are still some technical challenges in that classical IPMCs have poor humidity sensing performance due to their dense surface electrode, and IPMCs are damaged easily due to an electrode/membrane mismatch. In this work, through the spraying and electrodepositing process, we developed an efficient method to rapidly prepare a Au-shell-Ag-NW (silver nanowire)-based IPMC with high strength, low surface resistance and excellent humidity sensing performance. Meanwhile, we optimized the preparation method by clarifying the influence of solvent type and electrodepositing time on the performance of the Au-shell-Ag-NW-based IPMC, thus effectively improving the humidity sensing effect and strength of the IPMC. Compared with previous research, the humidity electrical response (~9.6 mV) of the Au-shell-Ag-NW-based IPMC is at least two orders of magnitude higher than that of the classical IPMC (~0.41 mV), which is mainly attributed to the sparse gap structure for promoting the exchange of water molecules in the environment and Nafion membrane, a low surface resistance (~3.4 Ohm/sq) for transmitting the signal, and a seamless connection between the electrode and Nafion membrane for fully collecting the ion charges in the Nafion membrane. Additionally, the Au-shell-Ag-NW-based IPMC could effectively monitor the human breathing process, and the humidity sensing performance did not change after being exposed to the air for 4 weeks, which further indicates that the Au-shell-Ag-NW-based IPMC has good application potential due to its efficient preparation technology, high stability and good reproducibility.

23 October 2022 in Machines
Verified
Journal Article
Open access
PDF file
XZXIN ZHAO
XIN ZHAO
GTGangqiang Tang
Gangqiang Tang
ZCzhao chun
zhao chun
MDMei Dong
Mei Dong
YJYujun Ji
Yujun Ji
Yanjie WangYanjie Wang
Yanjie Wang
Inspired by the mechanism of touch and pain in human skin, we integrated two ion-sensing films and a polydimethylsiloxane (PDMS) layer together to achieve a bionic artificial receptor with the capacity of distinguishing touch or pain perception through ion-electrical effect. The ion-sensing film provides the carrier of touch or pain perception, while the PDMS layer as a soft substrate is used to regulate the perception ability of receptor. Through a series of experiments, we investigated the effects of physical properties of the PDMS layer on the sensing ability of an artificial receptor. Further, contact area tests were performed in order to distinguish touch or pain under a sharp object. It is revealed that the pressure threshold triggering the touch and pain feedback of the artificial receptor presented an increasing trend when the elastic modulus and thickness of the PDMS substrate increase. The distinction ability of touch and pain becomes more pronounced under higher elastic modulus and larger thickness. Furthermore, the induced pain feedback becomes more intense with the decrease of the loading area under the same load, and the threshold of pain drops down from 176.68 kPa to 54.57 kPa with the decrease of the radius from 3 mm to 1 mm. This work potentially provides a new strategy for developing electronic skin with tactile sensing and pain warning. The pressure threshold and sensing range can be regulated by changing the physical properties of the middle layer, which would be advantageous to robotics and healthcare fields.
1

13 October 2023
Verified
Book Chapter
Closed access
PDF file
YJYujun Ji
Yujun Ji
GTGangqiang Tang
Gangqiang Tang
CZChun Zhao
Chun Zhao
YPYifan Pan
Yifan Pan
DZDenglin Zhu
Denglin Zhu
Yanjie WangYanjie Wang
Yanjie Wang