1 May 2021 in Biomedical Signal Processing and Control
6 June 2020 in Research on Biomedical Engineering
29 March 2017 in Journal of Intelligent & Fuzzy Systems: Applications in Engineering and Technology
Digital fundus photography plays a major role in the diagnosis of different retinal pathologies like hypertension, diabetic retinopathy and Glaucoma. To identify abnormal components on the retina, retinal features should be detected accurately. Retinal vessel structure is one of the important landmarks of the retina. So precise detection of retinal vessel structure is imperative. This paper presents a simple, robust retinal vessel extraction approach based on the line detectors and morphological operations. As vessel detection is basically a problem of a line detection, the green channel retinal image is applied to morphological opening using a line as structuring element. The resultant image is again applied with the line detectors and thresholded using Otsu’s thresholding. The proposed algorithm overcomes the fundamental issues of scale and orientation avoiding the need of multiple thresholds with improved values of performance measure as compared to the state of the art techniques. The proposed algorithm is applied on 3 standard databases-HRF (healthy and Diabetic), DIARETDB1 and DRIVE. Area under the ROC curve (AUC) of 97% was achieved with 91% Sensitivity and 97% Specificity for DRIVE dataset. The proposed algorithm achieved an Accuracy of 97%, Sensitivity of 85 % and Specificity of 97% for HRF database. On DIARETDB1 database too observed very good results.
13 December 2024 in Biomedical Engineering: Applications, Basis and Communications
Retinal Disease analysis using fundus photography needs the expertise from engineering domain. Using fundus photographs provides a non-invasive way to inspect the retina of human eye and in turn the window for human vasculature. Retina of human eye gets affected with abnormalities as a result of diabetic and hypertensive retinopathy. In order to recognize the abnormalities and grade the severity of disease, it is indeed required to locate the retinal landmarks accurately. Exact identification of Retinal vasculature in terms of position and diameter is imperative. A computationally simple, robust, effectively extracting tiny vessels and rotation invariant vessel identifier algorithm is proposed. The process is carried out in four steps — (i) A novel morphological contrast enhancement — high boost filtering (MCE-HBF) method is used for gray scale version of input fundus image. (ii) Extraction and the dark objects enhancement are carried out using high boost filtering. (iii) A single optimal threshold is used for segmentation of the dark objects. (iv) Non-vascular objects and noise are removed and a clear vessel tree is extracted at the end. The proposed algorithm has reported a sensitivity of 0.82, 0.82, 0.81; specificity of 0.99, 0.97, 0.98; accuracy of 0.97, 0.96, 0.97; precision of 0.87, 0.64, 0.81 and false positive rate of 0.0081, 0.0218, 0.010 on HRF healthy, HRF diabetic and DRIVE dataset images, respectively. With the lowest possible false positive rate, the proposed approach offers a scale and rotation invariant method for extracting minute blood vessels. The algorithm has shown better results than the state-of-the-art outcomes when tested on the HRF and DRIVE Datasets. The photos from the DiaretDB1 dataset show that the results are also useful.