Kaijing Mao

Kaijing Mao

Auto-generated profile, based on publicly available information

Kaijing Mao

Faculty of Dentistry, The University of Hong Kong, Hong Kong Special Administrative Region, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 January 2025 in International Dental Journal
Verified
Journal Article
Open access
Reinhard Chun Wang ChauReinhard Chun Wang Chau
Reinhard Chun Wang Chau
ACAndrew Chi Chung Cheng
Andrew Chi Chung Cheng
KMKaijing Mao
Kaijing Mao
Khaing Myat ThuKhaing Myat Thu
Khaing Myat Thu
ZLZhaoting Ling
Zhaoting Ling
Walter LamWalter Lam
Walter Lam
Periodontal disease is a significant public health concern among older adults due to its relationship with tooth loss and systemic health disease. However, there are numerous barriers that prevent older adults from receiving routine dental care, highlighting the need for innovative screening tools at the community level. This pilot study aimed first, to evaluate the accuracy of GumAI, a new mHealth tool that uses AI and smartphones to detect gingivitis, and the user acceptance of personalized oral hygiene instructions provided through the new tool, among older adults in day-care community centers. Participants were invited from 3 day-care community centers. Intraoral photographs were captured and assessed by both GumAI (test) and a panel consisting of 2 calibrated periodontists and a dentist (benchmark). Mean sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, and F1 score were calculated to determine GumAI's diagnostic performance in comparison to the benchmark. User acceptance with this tool was assessed using 2 Rasch Theory-based 5-point Likert-type questions. 44 participants were recruited out of 80 invited older adults. GumAI demonstrated a sensitivity of 0.93 and specificity of 0.50 compared to the panel's assessments, with a PPV of 0.90 and NPV of 0.56. The accuracy and F1 scores were 0.85 and 0.91, respectively. All participants expressed high acceptance of the process. GumAI demonstrates high sensitivity, PPV, accuracy, and F1 score compared to the panel's assessments but falls relatively short in specificity and NPV. Despite this, the tool was highly accepted by older adults, indicating its potential to enhance gingivitis detection and oral hygiene management in community settings. Further refinements are necessary to improve specificity and validate usability measures. This study may pave the way for broader applications of mHealth systems in community settings, enabling greater health coverage and addressing oral health disparities.

29 November 2025 in International Dental Journal
Verified
Journal Article
Open access
Walter LamWalter Lam
Walter Lam
ZLZhaoting Ling
Zhaoting Ling
KMKaijing Mao
Kaijing Mao
JPJi-Man Park
Ji-Man Park
AZAmirali Zandinejad
Amirali Zandinejad
FSFalk Schwendicke
Falk Schwendicke
Digital technologies are transforming oral healthcare by enhancing prevention, diagnostics, treatment, and maintenance procedures. However, few comprehensive reviews have synthesized their clinical applications across dental disciplines. This scoping review maps the clinical applications of digital dentistry and informed the development of a 2025 FDI Policy Statement that will guide stakeholders in recognizing both significant advances and ongoing challenges. A systematic search of PubMed, Embase, and Web of Science identified 407 eligible articles. Applications clustered into 2 domains: Disease prevention and diagnosis - preventive dentistry (n = 39), cariology (n = 26), and periodontology (n = 16), and Management of disease consequences and patient care - prosthodontics (n = 127), oral and maxillofacial surgery (n = 112), orthodontics (n = 26), and perioperative management (n = 61). Digital dentistry encompasses artificial intelligence, computer-aided design-computer-aided manufacturing (CAD-CAM) technologies, computer-assisted surgery systems, digital imaging, teledentistry, and related devices and systems. Evidence supporting digital applications should be critically evaluated, and professional judgment must remain central to patient care. Advancing the field will require more standardized, high‑quality data and clinical research to establish robust evidence of real‑world impact.

15 July 2025 in International Dental Journal
Verified
Journal Article
Open access
KMKaijing Mao
Kaijing Mao
Khaing Myat ThuKhaing Myat Thu
Khaing Myat Thu
Kuo Feng HungKuo Feng Hung
Kuo Feng Hung
Ollie Yiru YuOllie Yiru Yu
Ollie Yiru Yu
Tai-Chiu HsungTai-Chiu Hsung
Tai-Chiu Hsung
Walter LamWalter Lam
Walter Lam
This systematic review aims to evaluate the methodological characteristics and clinical performance of artificial intelligence (AI) models in detecting periodontal disease using digital intraoral photographs. This review includes peer-reviewed publications and conference proceedings in English, focusing on clinical studies of human periodontal diseases. Intraoral photographs served as the primary data source, with fluorescent and microscopic dental images excluded. The methodological characteristics and performance metrics of clinical studies reporting on AI models were analysed. Twenty-six studies met the review criteria. Various image acquisition devices were used by the resarchers including professional cameras, intraoral cameras, smartphones, and home-use devices. Ten studies used clinical examinations as reference methods, while 16 used visual examinations. Eight studies involved multiple experts in dataset annotation. Only 9 studies employed multiple intraoral views for their AI models, with the remaining studies focusing solely on the frontal view. Regarding AI tasks, 17 studies used classification, 4 used detection, and 5 used segmentations. Performance metrics varied widely and were assessed at multiple levels. Classification studies showed accuracies ranging from 0.46 to 1.00, detection studies showed accuracies from 0.56 to 0.78, and segmentation studies achieved Intersection over Union (IoU) scores of 0.43 to 0.70. AI models show potential for detecting periodontal disease from intraoral photographs, but their clinical use faces challenges. Future research should focus on improving reporting standards, standardising evaluation metrics, performing external tests, enhancing data quality, and using clinical gold standards as reference methods. Furthermore, efforts should focus on promoting transparency, integrating ethical considerations, minimising misclassification, and advancing the development of explainable and user-friendly AI systems to enhance their clinical applicability and reliability.

8 April 2025 in Journal of Dentistry
Verified
Journal Article
Open access
JKJason Chi-Kit Ku
Jason Chi-Kit Ku
KMKaijing Mao
Kaijing Mao
FWFeifei Wang
Feifei Wang
ACAdriana da Fonte Porto Carreiro
Adriana da Fonte Porto Carreiro
Walter LamWalter Lam
Walter Lam
Ollie Yiru YuOllie Yiru Yu
Ollie Yiru Yu
To evaluate the accuracy of visual caries detection using clinical photographs in comparison with visual clinical intraoral examination for the detection of dental caries. This review followed PRISMA-DTA guidelines and was registered in PROSPERO (CRD42024598814). Accuracy parameters of sensitivity, specificity and diagnostic odds ratio (DOR), area under summary receiver operating characteristic curve (AUC), and partial AUC (pAUC) were generated. Risk of bias was assessed using QUADAS-2 tool. Publications from PubMed, Web of Science, Scopus, and EMBASE databases. Eighteen studies including 1300 participants were included in this review. Risks of bias and applicability concerns were frequently encountered in one or more domains. The pooled sensitivity (95 % Confidence Interval, CI), specificity (95 %CI), DOR (95 %CI) and AUC (pAUC) of the visual assessment of clinical photographs were 0.74 (0.70-0.77), 0.95 (0.88-0.98), 52.94 (22.13-126.66), and 0.813 (0.753) for enamel caries; 0.81 (0.75-0.86), 0.98 (0.94-0.99), 142.01 (67.50-298.77), and 0.935 (0.857) for dentine caries; 0.81 (0.70-0.89), 0.99 (0.96-1.00), 245.04 (83.75-716.96), and 0.957 (0.902) for any caries depth. Subgroup analysis suggested that caries depth (enamel caries v.s. dentine caries v.s. any caries depth; p = 0.072), dentition (primary v.s. permanent; p = 0.584 (dentine caries data), p = 0.923 (any caries data)), technology (smartphone camera v.s. intra-oral camera; p = 0.993), and photographer (dental professional v.s. layperson; p = 0.466) did not modify the diagnostic performance. Visual assessment of clinical photographs for caries detection demonstrated clinically acceptable accuracy when compared with visual clinical intraoral examination. High specificity values across diagnostic thresholds suggest a high level of accuracy in correctly identifying sound tooth structure. Clinical photography is useful for dental caries detection and can facilitate clinical decision-making.

30 May 2026 in Journal of Dentistry
Verified
Journal Article
Open access
Reinhard Chun Wang ChauReinhard Chun Wang Chau
Reinhard Chun Wang Chau
ZGZhuohong Gong
Zhuohong Gong
ACAndrew Chi Chung Cheng
Andrew Chi Chung Cheng
KMKaijing Mao
Kaijing Mao
Khaing Myat ThuKhaing Myat Thu
Khaing Myat Thu
Walter LamWalter Lam
Walter Lam
This study aimed to externally validate the screening performance of a pro-social (equitable, accessible), explainable AI (XAI)-guided mobile health (mHealth) tool, GumAI, that automated the analysis of smartphone photographs to detect signs of gingival inflammation in community-dwelling older adults, a condition that is common yet often undiagnosed due to limited access to dental care. Older adults (age 60+) were recruited from nine community centres. Frontal intraoral photographs were captured with smartphones and evaluated using an mHealth tool that classified gingival regions as "no inflammation" (health) in green, "mild changes/questionable" in yellow, or "inflamed" (diseased) in red at the pixel level. In this study, the screening performance was validated only for visible anterior teeth. Two calibrated periodontists independently assessed these photographs, annotated the regions of healthy/mild changes/questionable/diseased, and served as the benchmark for comparison. Performance metrics, including sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), accuracy, F1-score, and mean intersection over union (mIOU), were calculated by comparing the AI outputs to the benchmark. Of 262 invited older adults, 163 (62.21%) participated, and each centre recruited 17-44 participants. Inter-rater agreement between periodontists was substantial (Prevalence- and Bias-Adjusted Kappa (PABAK) = 0.62). GumAI exhibited sensitivity of 0.91 (95% CI 0.91-0.92), specificity of 0.87 (95% CI 0.87-0.87), PPV of 0.90 (95% CI 0.89-0.90), NPV of 0.89 (95% CI 0.89-0.89), accuracy of 0.89 (95% CI 0.89-0.89), F1-score of 0.90, and mIOU of 0.83. The mHealth tool demonstrated potential to detect visual signs of gingival inflammation in intraoral photographs of older adults in a community setting, with results comparable to those of periodontists' visual annotations. This supports its utility as a pro-social XAI screening solution for scalable, community-based oral health promotion, warranting further refinement and validation against clinical probing. The mHealth tool enables non-invasive, readily accessible, and near-real-time detection of visual signs of gingival inflammation in intraoral photographs. This approach may facilitate early identification of individuals who require referral, support, home care reinforcement, and enable timely intervention for underserved older adults in community settings. Further clinical studies, including validation against periodontal probing, are needed to fully evaluate its potential to promote oral health through scalable community-based screening.

20 March 2025 in Diagnostics
Verified
Journal Article
Open access
PDF file
KMKaijing Mao
Kaijing Mao
Qi Yong Hemis AiQi Yong Hemis Ai
Qi Yong Hemis Ai
Kuo Feng HungKuo Feng Hung
Kuo Feng Hung
ITIrene O. L. Tse
Irene O. L. Tse
HLHo Sang Leung
Ho Sang Leung
AKAnn D. King
Ann D. King
Background/Objectives: The detection of unknown primary tumours in the palatine tonsils (PTs) on imaging relies heavily on asymmetry in size between the right and left sides, but the expected normal range in asymmetry is not well documented. This study aimed to document the expected range of asymmetry in the size of the PTs in adults without cancer. Methods: This retrospective study evaluated 250 pairs of normal PTs on MRIs of adults without head and neck cancer. The size (volume, V) of the PTs on the left and right sides were measured, and the percentage difference in volume (ΔV%) between the two sides was calculated. An additional analysis of PT volumes in 29 patients with ipsilateral early-stage palatine tonsillar cancer (PTCs) was performed. Results: In patients without PTC, the normal PTs had a mean volume of 3.0 ± 1.7 cm3, and there was a difference in size between the left and right PTs, showing a median ΔV% of 11.6% (range: 0.1–79.0%); most patients had a ΔV% of ≤40% (95%) for PTs. In patients with ipsilateral PTC, the normal PT had a smaller size compared with PTC (p < 0.01), showing a median ΔV% of 132.9% (range: 8.5–863.2%). Compared with patients without PTC, those with PTC showed a greater ΔV% (p < 0.01). An optimal ΔV% threshold of >39.6% achieved the best accuracy of 95% for identifying PTC. Conclusions: PTs are asymmetrical in size in adults without PTC. An additional analysis involving patients with PTC confirmed a threshold of ΔV% of 40% for PTs, which may be clinically valuable to help detect pathology using MRI.