Raymond Fang

Raymond Fang

Auto-generated profile, based on publicly available information

Raymond Fang

Department of Biomedical Engineering, Northwestern University, Evanston, IL, USA

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 January 2022 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
IRIan Rubinoff
Ian Rubinoff
DMDavid A. Miller
David A. Miller
RKRoman Kuranov
Roman Kuranov
YWYuanbo Wang
Yuanbo Wang
RFRaymond Fang
Raymond Fang
HZHao F. Zhang
Hao F. Zhang
Increases in speed and sensitivity enabled rapid clinical adoption of optical coherence tomography (OCT) in ophthalmology. Recently, visible-light OCT (vis-OCT) achieved ultrahigh axial resolution, improved tissue contrast, and provided new functional imaging capabilities, demonstrating the potential to improve clinical care further. However, limited speed and sensitivity caused by the high relative intensity noise (RIN) in supercontinuum lasers impeded the clinical adoption of vis-OCT. To overcome these limitations, we developed balanced-detection vis-OCT (BD-vis-OCT), which uses two calibrated spectrometers to cancel RIN and other noises. We analyzed the RIN to achieve robust subpixel calibration between the two spectrometers and showed that BD-vis-OCT reduced the A-line noise floor by up to 20.5 dB. Metrics comparing signal-to-noise-ratios showed similar image qualities across multiple reference arm powers, a hallmark of operation near the shot-noise limit. We imaged healthy human retinas at an A-line rate of 125 kHz and a field-of-view up to 10 mm $\times4$ mm. We found that BD-vis-OCT revealed retinal anatomical features previously obscured by the noise floor.

5 March 2021 in Journal of Trauma and Acute Care Surgery
Verified
Journal Article
Open access
STSharven Taghavi
Sharven Taghavi
ZMZoe Maher
Zoe Maher
AGAmy J. Goldberg
Amy J. Goldberg
GCGrace Chang
Grace Chang
MMMichelle Mendioloa
Michelle Mendioloa
DTDanielle Tatum
Danielle Tatum
BACKGROUND: Prehospital procedures (PHP) by emergency medical services (EMS) are performed regularly in penetrating trauma patients despite previous studies demonstrating no benefit. We sought to examine the influence of PHPs on outcomes in penetrating trauma patients in urban locations where transport to trauma center is not prolonged. We hypothesized that patients without PHPs would have better outcomes than those undergoing PHP. METHODS: This was an Eastern Association for the Surgery of Trauma–sponsored, multicenter, prospective, observational trial of adults (18+ years) with penetrating trauma to the torso and/or proximal extremity presenting at 25 urban trauma centers. The impact of PHPs and transport mechanism on in-hospital mortality were examined. RESULTS: Of 2,284 patients included, 1,386 (60.7%) underwent PHP. The patients were primarily Black (n = 1,527, 66.9%) males (n = 1,986, 87.5%) injured by gunshot wound (n = 1,510, 66.0%) with 34.1% (n = 726) having New Injury Severity Score of ≥16. A total of 1,427 patients (62.5%) were transported by Advanced Life Support EMS, 17.2% (n = 392) by private vehicle, 13.7% (n = 312) by police, and 6.7% (n = 153) by Basic Life Support EMS. Of the PHP patients, 69.1% received PHP on scene, 59.9% received PHP in route, and 29.0% received PHP both on scene and in route. Initial scene vitals differed between groups, but initial emergency department vitals did not. Receipt of ≥1 PHP increased mortality odds (odds ratio [OR], 1.36; 95% confidence interval [CI], 1.01–1.83; p = 0.04). Logistic regression showed increased mortality with each PHP, whether on scene or during transport. Subset analysis of specific PHP revealed that intubation (OR, 10.76; 95% CI, 4.02–28.78; p < 0.001), C-spine immobilization (OR, 5.80; 95% CI, 1.85–18.26; p < 0.01), and pleural decompression (OR, 3.70; 95% CI, 1.33–10.28; p = 0.01) had the highest odds of mortality after adjusting for multiple variables. CONCLUSION: Prehospital procedures in penetrating trauma patients impart no survival advantage and may be harmful in urban settings, even when performed during transport. Therefore, PHP should be forgone in lieu of immediate transport to improve patient outcomes. LEVEL OF EVIDENCE: Prognostic, level III.

1 March 2023 in Journal of Urology
Verified
Journal Article
Closed access
AHAndrew M. Harris
Andrew M. Harris
STSeth Teplitsky
Seth Teplitsky
KKKate H. Kraft
Kate H. Kraft
RFRaymond Fang
Raymond Fang
WMWilliam Meeks
William Meeks
ANAmanda North
Amanda North
Purpose:We hypothesize burnout has failed to improve and certain demographics may be disproportionately affected.Materials and Methods:The AUA Workforce Workgroup examined work from the annual AUA ...

1 November 2017 in Urology Practice
Verified
Journal Article
Open access
BBBenjamin N. Breyer
Benjamin N. Breyer
RFRaymond Fang
Raymond Fang
WMWilliam Meeks
William Meeks
DLDeborah Lightner
Deborah Lightner
JCJ. Quentin Clemens
J. Quentin Clemens
Through systematic data review and expert consensus, the AUA (American Urological Association) produces clinical practice guidelines that serve to provide evidence-based guidance with an explicit clinical scope and purpose. In this study we determined whether urologists use clinical practice guidelines when making clinical decisions, and whether demographic factors are associated with not using the guidelines or with a lack of guideline awareness. We examined the 2014 AUA Census. Our outcome was a question regarding whether the participant used AUA clinical practice guidelines in clinical decision making. We performed comparative statistical analyses, stratifying our outcome by demographic and practice specific variables. A total of 2,204 urologists completed the census, representing 18.9% of practicing urologists in the United States. Median age was 53 years and 91.1% were male. The majority of urologists used clinical practice guidelines (94.8%) in clinical decision making. Clinical practice guidelines had the lowest use among urologists 65 years old or older (89.2%), those in solo practice (88.3%) and pediatric specialists (87.9%). Based on a multivariable logistic regression analysis, factors associated with not using clinical practice guidelines included increasing age, metropolitan practice setting and solo practice. Gender, AUA section, level of rurality and fellowship training were not statistically associated with clinical practice guideline use. The majority of urologists (approximately 95%) use AUA clinical practice guidelines to inform clinical decisions. Our findings support the importance of clinical practice guidelines and highlight potential opportunities for better targeted outreach to improve clinical practice guideline use among practicing urologists.

17 June 2025 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
RFRaymond Fang
Raymond Fang
PZPengpeng Zhang
Pengpeng Zhang
TZTingwei Zhang
Tingwei Zhang
ZYZihang Yan
Zihang Yan
DKDaniel Kim
Daniel Kim
HZHao F. Zhang
Hao F. Zhang
Imaging complex, non-planar anatomies with optical coherence tomography (OCT) is limited by the optical field of view (FOV) in a single volumetric acquisition. Combining linear mechanical translation with OCT extends the FOV but suffers from inflexibility in imaging non-planar anatomies. We report the robotic OCT to fill this gap. To address challenges in volumetric reconstruction associated with the robotic movement accuracy being two orders of magnitudes worse than OCT imaging resolution, we developed a volumetric montaging algorithm. To test the robotic OCT, we imaged the entire circumferential aqueous humor outflow pathway, whose imaging has the potential to customize glaucoma surgeries but is typically constrained by the FOV in mice in vivo. We acquired volumetric OCT data at different robotic poses and reconstructed the entire anterior segment of the eye. From the segmented Schlemm’s canal volume, we showed its circumferentially heterogeneous morphology; we also revealed a segmental nature in the circumferential distribution of collector channels with spatial features as small as a few micrometers.

12 February 2024 in Biomedical Optics Express
Verified
Journal Article
Closed access
BBBenjamin Brenner
Benjamin Brenner
FXFengyuanshan Xu
Fengyuanshan Xu
YZYang Zhang
Yang Zhang
JKJunghun Kweon
Junghun Kweon
RFRaymond Fang
Raymond Fang
HZHao F. Zhang
Hao F. Zhang
Mitochondrial morphology provides unique insights into their integrity and function. Among fluorescence microscopy techniques, 3D super-resolution microscopy uniquely enables the analysis of mitochondrial morphological features individually. However, there is a lack of tools to extract morphological parameters from super-resolution images of mitochondria. We report a quantitative method to extract mitochondrial morphological metrics, including volume, aspect ratio, and local protein density, from 3D single-molecule localization microscopy images, with single-mitochondrion sensitivity. We validated our approach using simulated ground-truth SMLM images of mitochondria. We further tested our morphological analysis on mitochondria that have been altered functionally and morphologically in controlled manners. This work sets the stage to quantitatively analyze mitochondrial morphological alterations associated with disease progression on an individual basis.