Fethi Achi

Fethi Achi

Auto-generated profile, based on publicly available information

Fethi Achi

Laboratory of Valorization and Promotion of Saharian Ressources, Kasdi Merbah University, Ouargla, Algeria

Research Focus & Metrics

Academic Career Length

12Years (2015-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 July 2022 in Sensors & Diagnostics
Verified
Journal Article
Open access
PDF file
HMHicham Meskher
Hicham Meskher
FAFethi Achi
Fethi Achi
HMHicham Meskher
Hicham Meskher
BBBahria Berregui
Bahria Berregui
FBFatiha Babanini
Fatiha Babanini
HBHakim Belkhalfa
Hakim Belkhalfa
Hazardous phenols including penta-chlorophenol (5-CP) are considered an emerging global issue because they are toxic and harmful not only to the environment but also to the human health. Hence, detection of 5-CP traces is crucial for the safety. Compared to other analytical tools, electrochemical sensing approaches are cheap, fast, robust, and accurate in reliable characterization, identification, and quantification of 5-CP. For this purpose, this paper reports for the first time a novel synthesis procedure of an outstanding nanocomposite rGO/MOF and investigates its applicability to 5-CP identification. The synthesized materials were characterized by using scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray fluorescence (XRF). The electrochemical analysis of the developed sensor using cyclic voltammetry (CV), electrochemical impedance spectroscopy (EIS), and square wave voltammetry (SWV) demonstrate that the synthesized sensor had a high electrical conductivity and a significantly high catalytic activity. At a potential of 0.7 V (vs. SCE), 5-CP exhibits distinct oxidation peaks in the measured CV curves. The sensor works well over a wide linear range of 5-CP concentrations ranging from 50 μM to 200 μM. It achieves a sensitivity of 3.4 nA nM−1 and a limit of detection of 75.63 nM, while the quantification limit is estimated to be around 254.54 nM. In addition, an artificial neural network (ANN) algorithm was developed and used to analyze the experimental data and offer an accurate estimation of 5-CP concentrations. The obtained results of the sensor are promising for the development of a low-cost 5-CP sensing system for in-field investigations (screening) of aquatic environments requiring the detection of environmental hazards.

13 December 2021 in Analytical Letters
Verified
Journal Article
Closed access
HMHicham Meskher
Hicham Meskher
FAFethi Achi
Fethi Achi
AZAhmed Zouaoui
Ahmed Zouaoui
Sohmyung HaSohmyung Ha
Sohmyung Ha
MPMartin Peacock
Martin Peacock
HBHakim Belkhalfa
Hakim Belkhalfa
A new electrochemical sensor is reported based on a modified platinum (Pt) electrode sequentially drop-casting doped with functionalized multi-walled carbon nanotubes (fMWCNTs) decorated by reduced graphene oxide (rGO) and nickel oxide (NiO) nanoparticles (NPs). The NiO/rGO/fMWCNTs nanohybrid was characterized by Fourier transform infrared spectroscopy (FT-IR), field emission scanning electron microscopy (SEM), X-ray diffraction (XRD), and X-ray fluorescence (XRF). This sensor was employed for the simultaneous determination of catechol and hydroquinone. In the cyclic voltammetry (CV) results for a binary mixture of catechol and hydroquinone, the peak potentials of the two dihydroxybenzene isomers were separated by more than 105 mV, demonstrating the ability of the fabricated sensor to simultaneously determine the analytes. The NiO/rGO/fMWCNTs/Pt electrode exhibited a wide linear range of 10–300 μM with detection limits of 19.86 and 40.18 nM based upon a signal-to-noise ratio of 3 for catechol and hydroquinone, respectively. Furthermore, using differential pulse voltammetry (DPV), the sensor maintained well-defined peaks, demonstrating suitable selectivity. In addition, the NiO/rGO/fMWCNTs/Pt nanocomposite exhibits stability values of 92.3% and 91.6% for catechol and hydroquinone with excellent repeatability. The sensor analyzed water samples with spike recoveries from 90% to 106.66% for catechol and 88% to 98.66% for hydroquinone, respectively.

30 June 2022 in Materials Chemistry and Physics
Verified
Journal Article
Closed access
FMFatah Ben Moussa
Fatah Ben Moussa
FAFethi Achi
Fethi Achi
HMHicham Meskher
Hicham Meskher
Abddellah HenniAbddellah Henni
Abddellah Henni
HBHakim Belkhalfa
Hakim Belkhalfa

1 February 2015 in Sensors and Actuators B: Chemical
Verified
Journal Article
Closed access
FAF. Achi
F. Achi
SBS. Bourouina-Bacha
S. Bourouina-Bacha
MBM. Bourouina
M. Bourouina
AAAziz Amine
Aziz Amine

1 December 2020 in Colloids and Surfaces B: Biointerfaces
Verified
Journal Article
Closed access
ABAmira Bensana
Amira Bensana
FAFethi Achi
Fethi Achi