30 November 2021 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Transcranial ultrasound therapy has become a noninvasive method for treating neurological and psychiatric disorders, and studies have further demonstrated that multitarget transcranial ultrasound therapy is a better solution. At present, multitarget transcranial ultrasound therapy in small animals can only be achieved by the multitransducer or phased array. However, multiple transducers may cause spatial interference, and the phased array system is complicated, expensive, and especially unsuitable for small animals. This study is the first to design and fabricate a miniature acoustic holography lens for multitarget transcranial ultrasound therapy in rats. The acoustic holographic lens, working at a frequency of 1.0 MHz, with a size of 10.08 mm $\times10.08$ mm and a pixel resolution of 0.72 mm, was designed, optimized, and fabricated. The dual-focus transcranial ultrasound generated based on the lens was measured; the full-width at half-maximum (FWHM) of the focal spots in the ${y}$ -direction was 2.15 and 2.27 mm and in the ${z}$ -direction was 2.3 and 2.36 mm. The focal length was 5.4 mm, and the distance between the two focuses was 5.6 mm, close to the desired values of 5.4 and 6.0 mm. Finally, the multiple-target blood–brain barrier opening in rats’ bilateral secondary visual cortex (mediolateral area, V2ML) was demonstrated using the transcranial ultrasound therapy system based on the lens. These results demonstrate the good performance of the multitarget transcranial ultrasound therapy system for small animals, including high spatial resolution, small size, and low cost.
6 January 2022 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Transcranial focused ultrasound (tFUS) is increasingly used in experimental neuroscience due to its neuromodulatory effectiveness in animal studies. However, achieving multitarget tFUS in small animals is typically limited by transducer size, energy transfer efficiency, and brain volume. The objective of this work was to construct an ultrasound system for multitarget neuromodulation in small animals. First, a miniaturized high-powered 2-D array transducer was developed. The phase delay of each array element was calculated based on the multifocal time-reversal method, generating multiple foci simultaneously in a 3-D field. The effects of the axial focal length, interfocus spacing (lateral distance between the two focal centers), and the number of foci on the focal properties of the pressure field were examined through numerical simulations. In-vitro ultrasonic measurements and transcranial simulations on a rat skull were conducted. The minimum interfocus spacing separating two −6-dB foci and the peak full-width at half-maximum were positively correlated with axial focal length; the relative relationship between the interfocus spacing and pressure field properties was similar for each axial focal length. The maximum acoustic pressure and spatial average intensity at focus in deionized water were 2.21 MPa and 133 W/cm 2 , respectively. The simulated and experimental results were compared, demonstrating agreement in both peak position and focus shape. The ultrasound system can provide a neuroscientific platform for evaluating the feasibility of multitarget ultrasound stimulation treatment protocols, thus improving the understanding of functional neuroanatomy.
7 August 2023 in Ultrasonics
19 March 2026 in Advanced Science
Despite its growing potential as a noninvasive neuromodulation technology, the fundamental biophysical mechanism of focused ultrasound neuromodulation (FUN) remains elusive. Progress has been hampered by a persistent auditory confound, making it difficult to isolate the direct mechanical effects on neural circuits. To overcome this barrier, we employed two‐photon calcium imaging (2PCI) in the primary visual cortex (V1) of deafened mice. Here, this study identifies a sparse (<1.5%) and spatially distributed population of neurons that is robustly and directly activated by ultrasound in a pressure‐dependent manner. Crucially, this sparse, direct activation is sufficient to modulate the broader visual circuit, altering the response dynamics of neighboring neurons to visual stimuli. By unequivocally decoupling direct neuromodulation from auditory artifacts, the findings identify a key cellular substrate for FUN and establish a robust framework for future studies. This work paves the way for targeted investigations into the precise biophysical mechanisms governing the interaction between ultrasound and neurons.