20 May 2024 in Эндодонтия Today
AIM. Aim of this work is to substantiate the optimal characteristics of the apparatus for electroodontodiagnostics on the basis of studying the complex electrical resistance of tooth tissues.MATERIALS AND METHODS. The study of complex tissue resistance during electroodontodiagnostics in 50 patients aged from 18 to 55 years was carried out. A total of 181 teeth were studied. All the teeth studied were with formed roots. 52 teeth were intact, 40 teeth had been previously treated for caries, 26 teeth had carious process, 21 teeth were diagnosed with pulpitis, 9 teeth were diagnosed with periodontitis, 33 teeth had been previously subjected to endodontic treatment.RESULTS. The results of studying the complex tissue impedance during electroodontodiagnostics showed that the impedance module can be in a wide range from 120 kOhm to 3500 kOhm. At that, the main contribution to the complex impedance is made by the state of hard tissues of teeth.CONCLUSION. The obtained results showed that the device for electroodontodiagnostics should automatically in a continuous mode to measure impedance and according to it to control the supply of the necessary exponentially increasing alternating sinusoidal current with a frequency of 50 Hz.
30 May 2025 in Stomatologiya
The objective was to study the effect of complex electrical resistance of teeth on the electrical sensitivity testing values. Material and methods. The study of complex electrical resistance during electrical sensitivity testing was carried out in 70 patients aged 18 to 57 years. Males made up 48.6% and females 51.4%. A total of 254 teeth were examined. All the examined teeth had mature roots; 65 teeth were intact, 52 had previously been treated for caries, 38 teeth had dentine caries, 33 were diagnosed with pulpitis, 21 with periodontitis, 45 teeth had previously undergone endodontic treatment. Results. The main contribution to the complex electrical resistance during electrical sensitivity testing is made by the condition of the hard tissues of the teeth. In intact teeth, the impedance modulus was 3148±236.8. In the teeth where caries was treated, the impedance modulus was 2675±327.4 kOhm. In case of caries, i.e. when the active electrode was placed on the dentine of the tooth during the study, the module of complex electrical resistance decreased to 852±445.3 kOhm. The lowest values of the impedance modulus were in cases when the active electrode was located at the bottom of the tooth cavity, in the mouths of the root canals of teeth that had not previously undergone endodontic treatment, with pulpitis and periodontitis. Its values were 294±121.5 kOhm. In teeth with previously sealed root canals, the complex electrical resistance was 1253±297.8 kOhm. Conclusion. The results of the study showed that the module of complex electrical resistance, and, consequently, the electrical conductivity of tooth tissues during electrical sensitivity testing, can be in a wide range. These circumstances should be considered when choosing a technique for conducting electrical sensitivity testing in specific clinical situations.
20 December 2024 in Stomatologiya
The aim of the study. To determine the type of electric current with the greatest diagnostic value used to study the electrical sensitivity of teeth in inferior alveolar nerve neuritis. Materials and methods. We examined 32 patients aged from 22 to 57 years, in whom neuritis of the inferior alveolar nerve developed due to traumatic removal of the lower third molar. There were 14 females and 18 males. To determine the electrical sensitivity of teeth four types of electric current were investigated: direct pulsating current, two types of alternating pulsating current, and pulsating current of sinusoidal form with a frequency of 50 Hz. Results. Direct pulse current of rectangular form, pulsating current of rectangular form, as well as pulsating current decaying in amplitude showed low diagnostic value in the study of tooth electrical sensitivity against the background of inferior alveolar nerve neuritis. This was due to a high hardware error, a large scatter of readings during repeated measurements and insufficient power of the devices. The greatest diagnostic value was shown by the sinusoidal current with a frequency of 50 Hz, which does not cause polarization of tissues, is easily dosed, causes clear but not painful sensations, gives the smallest scatter of indicators in repeated studies. Conclusion. The comparative analysis of different types of current having the most adequate effect on the nerve-receptor —apparatus of the tooth at neuritis of the lower alveolar nerve has shown that the optimum parameters of the current correspond to the pulsating sinusoidal current with the frequency of 50 Hz.