Ramy Refaat Youssef Ghali

Ramy Refaat Youssef Ghali

Auto-generated profile, based on publicly available information

Ramy Refaat Youssef Ghali

Clinical Oncology and Nuclear Medicine Department, Faculty of Medicine, Ain Shams University

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2025 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
ASArindam Sanyal
Arindam Sanyal
AGArup Kumar Goswami
Arup Kumar Goswami
PTPrashant Kumar Tiwari
Prashant Kumar Tiwari
TSTirunagaru V. Sarathkumar
Tirunagaru V. Sarathkumar
AAAhmad Aziz Al-Ahmadi
Ahmad Aziz Al-Ahmadi
RGRamy N. R. Ghaly
Ramy N. R. Ghaly
The consequences of fossil fuel consumption are increasingly evident through various climate anomalies and severe environmental impacts. Renewable energy sources have emerged as popular alternatives due to their zero‐emission generation. However, the intermittent nature of renewables introduces uncertainty in the techno‐economic operation of power systems. This article presents a novel adaptive penetration approach designed to maximize profit while minimizing tail‐end risk for economic participation in the power market. The proposed adaptive strategy dynamically adjusts renewable energy penetration between 20% and 80%, based on real‐time renewable energy availability. A Discrete‐Time Markov Decision Process (DTMDP) is employed for decision‐making and profit estimation, incorporating probabilistic renewable generation models and energy storage arbitrage operations. Profit and risk are evaluated over a 24‐h horizon across twelve months, with tail‐end risk quantified using Conditional Value at Risk (CVaR). This study models wind and solar energy generation probabilistically and integrates a two‐stage energy storage arbitrage system. In the first stage, excess renewable generation is stored when supply exceeds demand, while in the second stage, stored energy is dispatched during power shortages. The IEEE 14‐bus system with hybrid generation is used as the case study. The adaptive approach is compared with static renewable penetration levels of 20% and 80%. Results show that while 20% penetration yields lower tail risk, it also produces lower profits. Conversely, 80% penetration results in higher profits but comes with increased tail‐end risk. Additionally, months with lower renewable energy probabilities, such as December, exhibited higher tail‐end risk compared to months like July with higher renewable availability. The adaptive penetration strategy achieved higher profits than the 20% scenario while maintaining lower tail‐end risk than the 80% scenario, demonstrating its effectiveness in balancing profitability and risk.

1 January 2026 in International Transactions on Electrical Energy Systems
Verified
Journal Article
Open access
NANadia Akkari
Nadia Akkari
Houari BOUDJELLAHouari BOUDJELLA
Houari BOUDJELLA
BKBiteur Kada
Biteur Kada
KSKamel A. Shoush
Kamel A. Shoush
RHRashed Abu Hammour
Rashed Abu Hammour
RGRamy N. R. Ghaly
Ramy N. R. Ghaly
Photovoltaic (PV) system penetration in modern power grids necessitates highly efficient and adaptive maximum power point tracking (MPPT) techniques to avoid multiple local power peaks under partial shading conditions (PSCs), such as both static and dynamic irradiation conditions. This study addresses global MPPT in grid‐connected PV energy systems under PSC through comparative evaluation of the horse herd optimization algorithm (HOA) and four enhanced variants: Cauchy‐HOA, quasi‐opposition, and fast acceleration HOA (QC‐HOA‐FAST), multicomponent HOA (MCHOA), and hybrid HOA with pattern search (PS‐HOA). Each variant involved distinct mechanisms: stochastic diversification through Cauchy mutation, quasioppositional learning with faster convergence, adaptive weighting at multiple levels, and enhanced accuracy in local exploitation precision through pattern search hybridization. A grid‐connected PV system was tested under eight shading scenarios: four static (PSC1–PSC4) and four dynamic, with temporal variation (PSC5–PSC8). Under static conditions, QC‐HOA‐FAST achieved the fastest convergence [0.025–0.04 s] and the highest efficiency (up to 99.82%), although it significantly degraded under complex multimodal shading (79.74% in PSC4), while MCHOA and HOA‐PS maintained high efficiency (up to 99% and 98.49%, respectively), compared with the original HOA efficiency collapse, which reached 74.89%. Under dynamic shading, MCHOA outperforms HOA in relative efficiency under PSC7, reaching 99.99%, while Cauchy‐HOA ensures the best overall consistency, with an average relative efficiency of 98.7%, an improvement over the classic HOA; MCHOA, Cauchy‐HOA, and QC‐HOA‐FAST have also expanded their voltage tracking range to capture a higher peak power, up to 841 W in the most severe scenario (PSC7). Overall, MCHOA (95.55% ± 2.20) and HOA‐PS (95.55% ± 2.26) achieved the highest and most consistent overall tracking efficiency across all scenarios that was reported as significantly higher than the standard HOA by the Wilcoxon test. Throughout all scenarios, grid‐injected current recorded a total harmonic distortion (THD) between 2.42% and 2.46% below the limit of 5% (IEEE 519–2022). These results establish MCHOA and HOA‐PS as the most robust and generalizable MPPT strategies for maintaining high‐quality, high‐efficiency power extraction from a PV source under both static and highly dynamic partial shade.

1 October 2021 in QJM: An International Journal of Medicine
Verified
Journal Article
Open access
PDF file
MEMai Ezzat Elhawi
Mai Ezzat Elhawi
AAAly Mohammed Azmy
Aly Mohammed Azmy
RGRamy Refaat Youssef Ghali
Ramy Refaat Youssef Ghali
NGNagy Samy Gobran
Nagy Samy Gobran
MSMarwa Mosaad Shakweer
Marwa Mosaad Shakweer
DMDoaa Atef Mohammed
Doaa Atef Mohammed
Background: Locally advanced rectal cancer (LARC) has a high incidence of local and distant relapse even after adequate treatment. The emerging role of neoadjuvant induction chemotherapy may allow initial down staging of the primary tumor, less toxicity profile and early treatment of micrometastatic disease followed by chemoradiation, and optimum local control may be attained, with the hope of increased complete response rates Objectives: to identify the effect of induction chemotherapy with oxaliplatin and capecitabine (CapeOx) before concurrent chemoradiation in locally advanced rectal cancer in terms of response and toxicity. Primary end point is assessment of complete pathological response rate. Patient and Methods: patients with MRI based criteria of high-risk LARC (T4 tumors, tumors within 2 mm of mesorectal fascia, T3 tumors at or below levators and T2-4N+ve tumors) were included. Patients received 12 weeks of induction capecitabine/oxaliplatin followed by concomitant capecitabine and conventional three dimensional conformal radiotherapy. Surgery was done at least 6 weeks after CCRTH. Results: Thirty five patients with LARC were recruited during the period from December 2017 till January 2019. Five patients (20.8%) had a pathological complete response (TRG 0) (ypT0N0). Another three patients (12.5%) had near complete pathological response (TRG 1). While unfortunately 29.2% and 37.5% had partial response and poor response respectively. Conclusion: Induction chemotherapy could be a promising option for better response rates either clinical or pathological for high risk LARC patients with acceptable toxicity profile.