Eberhart Zrenner

Eberhart Zrenner

Auto-generated profile, based on publicly available information

Eberhart Zrenner

Institute for Ophthalmic Research, University of Tuebingen, Tuebingen, Germany

Research Focus & Metrics

Academic Career Length

33Years (1994-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
3 November 2010 in Proceedings Of The Royal Society B-Biological Sciences
Verified
Journal Article
Open access
EZEberhart Zrenner
Eberhart Zrenner
KBKarl Ulrich Bartz-Schmidt
Karl Ulrich Bartz-Schmidt
HBHeval Benav
Heval Benav
DBDorothea Besch
Dorothea Besch
ABAnna Bruckmann
Anna Bruckmann
RWRobert Wilke
Robert Wilke
A light-sensitive, externally powered microchip was surgically implanted subretinally near the macular region of volunteers blind from hereditary retinal dystrophy. The implant contains an array of 1500 active microphotodiodes (‘chip’), each with its own amplifier and local stimulation electrode. At the implant's tip, another array of 16 wire-connected electrodes allows light-independent direct stimulation and testing of the neuron–electrode interface. Visual scenes are projected naturally through the eye's lens onto the chip under the transparent retina. The chip generates a corresponding pattern of 38 × 40 pixels, each releasing light-intensity-dependent electric stimulation pulses. Subsequently, three previously blind persons could locate bright objects on a dark table, two of whom could discern grating patterns. One of these patients was able to correctly describe and name objects like a fork or knife on a table, geometric patterns, different kinds of fruit and discern shades of grey with only 15 per cent contrast. Without a training period, the regained visual functions enabled him to localize and approach persons in a room freely and to read large letters as complete words after several years of blindness. These results demonstrate for the first time that subretinal micro-electrode arrays with 1500 photodiodes can create detailed meaningful visual perception in previously blind individuals.

8 February 2002 in Science
Verified
Journal Article
Closed access
PDF file
EZEberhart Zrenner
Eberhart Zrenner
A number of research groups are developing electrical implants that can be attached directly to the retina in an attempt to restore vision to patients suffering from retinal degeneration. However, despite promising results in animal experiments, there are still several major obstacles to overcome before retinal prostheses can be used clinically.

1 June 2015 in Vision Research
Verified
Journal Article
Open access
KSKatarina Stingl
Katarina Stingl
KBKarl Ulrich Bartz-Schmidt
Karl Ulrich Bartz-Schmidt
DBDorothea Besch
Dorothea Besch
CCCaroline K. Chee
Caroline K. Chee
CCCharles L. Cottriall
Charles L. Cottriall
EZEberhart Zrenner
Eberhart Zrenner
A subretinal visual implant (Alpha IMS, Retina Implant AG, Reutlingen, Germany) was implanted in 29 blind participants with outer retinal degeneration in an international multicenter clinical trial. Primary efficacy endpoints of the study protocol were a significant improvement of activities of daily living and mobility to be assessed by activities of daily living tasks, recognition tasks, mobility, or a combination thereof. Secondary efficacy endpoints were a significant improvement of visual acuity/light perception and/or object recognition (clinicaltrials.gov, NCT01024803). During up to 12 months observation time twenty-one participants (72%) reached the primary endpoints, of which thirteen participants (45%) reported restoration of visual function which they use in daily life. Additionally, detection, localization, and identification of objects were significantly better with the implant power switched on in the first 3 months. Twenty-five participants (86%) reached the secondary endpoints. Measurable grating acuity was up to 3.3 cycles per degree, visual acuities using standardized Landolt C-rings were 20/2000, 20/2000, 20/606 and 20/546. Maximal correct motion perception ranged from 3 to 35 degrees per second. These results show that subretinal implants can restore very-low-vision or low vision in blind (light perception or less) patients with end-stage hereditary retinal degenerations.

1 January 1997 in Ophthalmic Research
Verified
Journal Article
Closed access
PDF file
EZE. Zrenner
E. Zrenner
KMK.-D. Miliczek
K.-D. Miliczek
VGV.P. Gabel
V.P. Gabel
HGH.G. Graf
H.G. Graf
EGE. Guenther
E. Guenther
SWS. Weiss
S. Weiss
There are presently several concepts to restore vision in blind or highly visually handicapped persons by implanting electronic devices into the eye in order to partially restore vision. Here, the approach to replace retinal photoreceptors by a sub-retinally implanted microphotodiode array (MPDA) is summarized. A survey is given on the present state of the development of MPDAs, the possibility of in vitro and in vivo tests as well as first results on biocompatibility and histology. Additionally, electrophysiological recordings in rabbits and rats are presented which have received such subretinal implants.

31 January 2022 in Nature Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
JKJasmina Kapetanovic
Jasmina Kapetanovic
MSMandeep S. Singh
Mandeep S. Singh
EZEberhart Zrenner
Eberhart Zrenner
RMRobert E MacLaren
Robert E MacLaren