Reagan R. D. Weeks

Reagan R. D. Weeks

Auto-generated profile, based on publicly available information

Reagan R. D. Weeks

Air Force Research Laboratory

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
28 March 2024 in Optica
Verified
Journal Article
Closed access
JMJohn J. McCauley
John J. McCauley
MPMark C. Phillips
Mark C. Phillips
RWReagan R. D. Weeks
Reagan R. D. Weeks
YZYu Zhang
Yu Zhang
SHSivanandan S. Harilal
Sivanandan S. Harilal
RJR. Jason Jones
R. Jason Jones
This Letter reports dual-frequency-comb spectroscopy in the deep ultraviolet used to characterize transient laser-produced plasmas. Dual-comb spectroscopy at these wavelengths enables access to a large number of strong electronic transitions in neutral and ionized atoms and molecules. This broadband dual-frequency-comb system at 265 nm measures multiple transitions in neutral and singly ionized iron atoms in a laser-produced plasma. Analysis of absorption spectra yields time-resolved ion and neutral column densities, excitation temperatures, and electron densities, which are measured down to 1014cm−3levels. The results provide insights into low-temperature plasma properties.

13 June 2022 in Journal of Applied Physics
Verified
Journal Article
Open access
PDF file
RWReagan R. D. Weeks
Reagan R. D. Weeks
YZYu Zhang
Yu Zhang
SHSivanandan S. Harilal
Sivanandan S. Harilal
MPMark C. Phillips
Mark C. Phillips
RJR. Jason Jones
R. Jason Jones
Dual-comb spectroscopy (DCS) represents a novel method of using absorption spectroscopy as a diagnostic tool for multispecies analysis of excitation temperatures and column densities in laser-produced plasmas (LPPs). DCS was performed on a LPP generated by ablating a multielement alloy containing Nd, Gd, and Fe. Transitions from all three elements were observed in absorption spectra measured from 530.08 to 535.19 nm at seven time-delays from 31 to 250 μs after ablation. The spectra were fit using a nonlinear regression algorithm to determine peak areas, and excitation temperatures and column densities were determined for the three atomic species separately using Boltzmann plots. The measured excitation temperatures of Nd I and Gd I showed good agreement at all time-delays, whereas the Fe I temperature was found to be higher, and the ratios between the column densities varied with delay. The observations are understood via effects of LPP spatial averaging, elemental fractionation, and molecular formation and are compared and contextualized with previous work studying LPPs using other spectroscopic techniques. A brief discussion of the precision and accuracy of the determined excitation temperatures and column densities is also presented.

19 December 2025 in Optics Letters
Verified
Journal Article
Closed access
RWReagan R. D. Weeks
Reagan R. D. Weeks
RLRyan A. Lane
Ryan A. Lane
BABrian M. Anderson
Brian M. Anderson
We present an all-fiber design for a Tm-based fiber amplifier that can tune over 1992–2065 nm with 300–350 W single-frequency (<100 kHz) output. Over 180 W is achieved out to 2085 nm with 2050 nm). Efficiencies of ∼55% are realized across the full bandwidth. Roll-off occurs beyond 2085 nm where ASE becomes intractable. The amplifier has an average M 2 value of 1.39 at high power due to the presence of light guided within the fiber pedestal. Estimates of the pedestal light and higher-order mode contents are provided.

3 August 2026 in Optics Letters
Verified
Journal Article
Closed access
PDF file
KTKelby B. Todd
Kelby B. Todd
MPMark C. Phillips
Mark C. Phillips
RWReagan R. D. Weeks
Reagan R. D. Weeks
RLRyan A. Lane
Ryan A. Lane
RJR. Jason Jones
R. Jason Jones
We demonstrate dual-comb spectroscopy (DCS) as an accurate and precise, non-contact, in-situ thermometry technique for gas-filled hollow-core fibers (HCFs). Measurements of the ν 1 + ν 3 band of 12 C 2 H 2 are performed over a ∼4 THz bandwidth, and rotational temperatures and total column densities are extracted via Boltzmann analysis of Voigt-fitted transitions. Retrieved temperatures agree with independent platinum resistance thermometer measurements within the uncertainty derived from a combination of fit standard errors. Our results show temperature retrievals accurate to within 3% over a temperature range of 21–51 ∘ C with a measurement precision better than 10% across 58 measurements. These results establish DCS as a powerful diagnostic tool for in-situ monitoring of HCF system performance.