Naoto Ohgami

Naoto Ohgami

Auto-generated profile, based on publicly available information

Naoto Ohgami

Omron Healthcare Co., Ltd., Muko, JP

Research Focus & Metrics

Academic Career Length

21Years (2006-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 April 2014 in Hypertension Research
Verified
Journal Article
Open access
PDF file
TIToshiyuki Iwahori
Toshiyuki Iwahori
HUHirotsugu Ueshima
Hirotsugu Ueshima
NMNaoko Miyagawa
Naoko Miyagawa
NONaoto Ohgami
Naoto Ohgami
HYHideyuki Yamashita
Hideyuki Yamashita
KMKatsuyuki Miura
Katsuyuki Miura
The objective of this study was to determine the optimal number and type of casual (spot) urine specimens required to estimate an individual’s urinary sodium/potassium (Na/K) ratio. A total of 48 participants, 25 men and 23 women, aged between 25 and 59 years, was recruited from healthy volunteers. The Na/K ratio in each casual urine and 7-day 24-h urine sample was measured. Correlation analysis and the quality of agreement by the Bland and Altman method between casual urine and 24-h urine were analyzed. The mean Na/K ratio of 7-day 24-h urine was 4.3. The mean Na/K ratio of six random specimens of daytime (collected between 09 and 17 hours) casual urine correlated most strongly with the Na/K ratio of 7-day 24-h urine (r=0.87). The bias for the mean Na/K ratio between 7-day 24-h urine and daytime casual urine was almost negligible (0.03), and the quality of agreement for the mean of the six random, daytime casual urine specimens on different days was similar to that of the 2-day 24-h urine samples for estimating 7-day 24-h values. Our findings show that the mean Na/K ratio of six random daytime casual urine specimens on different days was a good substitute for the 2-day 24-h urine Na/K ratio.

3 January 2012 in Journal of Periodontal Research
Verified
Journal Article
Closed access
PDF file
JKJ. Kido
J. Kido
MBM. Bando
M. Bando
YHY. Hiroshima
Y. Hiroshima
HIH. Iwasaka
H. Iwasaka
KYK. Yamada
K. Yamada
TNT. Nagata
T. Nagata

1 January 2018 in Journal of Epidemiology
Verified
Journal Article
Open access
PDF file
TIToshiyuki Iwahori
Toshiyuki Iwahori
HUHirotsugu Ueshima
Hirotsugu Ueshima
NONaoto Ohgami
Naoto Ohgami
HYHideyuki Yamashita
Hideyuki Yamashita
NMNaoko Miyagawa
Naoko Miyagawa
KMKatsuyuki Miura
Katsuyuki Miura
Japan's largest platform for academic e-journals: J-STAGE is a full text database for reviewed academic papers published by Japanese societies

1 February 2007 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
NONaoto Ohgami
Naoto Ohgami
SUSanjay Upadhyay
Sanjay Upadhyay
AKAyumi Kabata
Ayumi Kabata
KMKatsuya Morimoto
Katsuya Morimoto
HKHitoshi Kusakabe
Hitoshi Kusakabe
HSHiroaki Suzuki
Hiroaki Suzuki

1 January 2006 in Biosensors and Bioelectronics
Verified
Journal Article
Closed access
SUSanjay Upadhyay
Sanjay Upadhyay
NONaoto Ohgami
Naoto Ohgami
HKHitoshi Kusakabe
Hitoshi Kusakabe
HSHiroaki Suzuki
Hiroaki Suzuki

17 June 2021 in JMIR Pediatrics and Parenting
Verified
Journal Article
Open access
CHChizu Habukawa
Chizu Habukawa
NONaoto Ohgami
Naoto Ohgami
TATakahiko Arai
Takahiko Arai
HMHaruyuki Makata
Haruyuki Makata
MTMorimitsu Tomikawa
Morimitsu Tomikawa
KMKatsumi Murakami
Katsumi Murakami
Background: Since 2020, peoples’ lifestyles have been largely changed due to the COVID-19 pandemic worldwide. In the medical field, although many patients prefer remote medical care, this prevents the physician from examining the patient directly; thus, it is important for patients to accurately convey their condition to the physician. Accordingly, remote medical care should be implemented and adaptable home medical devices are required. However, only a few highly accurate home medical devices are available for automatic wheeze detection as an exacerbation sign. Objective: We developed a new handy home medical device with an automatic wheeze recognition algorithm, which is available for clinical use in noisy environments such as a pediatric consultation room or at home. Moreover, the examination time is only 30 seconds, since young children cannot endure a long examination time without crying or moving. The aim of this study was to validate the developed automatic wheeze recognition algorithm as a clinical medical device in children at different institutions. Methods: A total of 374 children aged 4-107 months in pediatric consultation rooms of 10 institutions were enrolled in this study. All participants aged ≥6 years were diagnosed with bronchial asthma and patients ≤5 years had reported at least three episodes of wheezes. Wheezes were detected by auscultation with a stethoscope and recorded for 30 seconds using the wheeze recognition algorithm device (HWZ-1000T) developed based on wheeze characteristics following the Computerized Respiratory Sound Analysis guideline, where the dominant frequency and duration of a wheeze were >100 Hz and >100 ms, respectively. Files containing recorded lung sounds were assessed by each specialist physician and divided into two groups: 177 designated as “wheeze” files and 197 as “no-wheeze” files. Wheeze recognitions were compared between specialist physicians who recorded lung sounds and those recorded using the wheeze recognition algorithm. We calculated the sensitivity, specificity, positive predictive value, and negative predictive value for all recorded sound files, and evaluated the influence of age and sex on the wheeze detection sensitivity. Results: Detection of wheezes was not influenced by age and sex. In all files, wheezes were differentiated from noise using the wheeze recognition algorithm. The sensitivity, specificity, positive predictive value, and negative predictive value of the wheeze recognition algorithm were 96.6%, 98.5%, 98.3%, and 97.0%, respectively. Wheezes were automatically detected, and heartbeat sounds, voices, and crying were automatically identified as no-wheeze sounds by the wheeze recognition algorithm. Conclusions: The wheeze recognition algorithm was verified to identify wheezing with high accuracy; therefore, it might be useful in the practical implementation of asthma management at home. Only a few home medical devices are available for automatic wheeze detection. The wheeze recognition algorithm was verified to identify wheezing with high accuracy and will be useful for wheezing management at home and in remote medical care.