25 January 2022 in Journal of NeuroInterventional Surgery
Background The benefit of best medical treatment including intravenous alteplase (IVT) before mechanical thrombectomy (MT) in patients with acute ischemic stroke and extensive early ischemic changes on baseline CT remains uncertain. The purpose of this study was to evaluate the benefit of IVT for patients with low ASPECTS (Alberta Stroke Programme Early CT Score) compared with patients with or without MT. Methods This multicenter study pooled consecutive patients with anterior circulation acute stroke and ASPECTS≤5 to analyze the impact of IVT on functional outcome, and to compare bridging IVT with direct MT. Functional endpoints were the rates of good (modified Rankin Scale (mRS) score ≤2) and very poor (mRS ≥5) outcome at day 90. Safety endpoint was the occurrence of symptomatic intracranial hemorrhage (sICH). Results 429 patients were included. 290 (68%) received IVT and 168 (39%) underwent MT. The rate of good functional outcome was 14.4% (95% CI 7.1% to 21.8%) for patients who received bridging IVT and 24.4% (95% CI 16.5% to 32.2%) for those who underwent direct MT. The rate of sICH was significantly higher in patients with bridging IVT compared with direct MT (17.8% vs 6.4%, p=0.004). In multivariable logistic regression analysis, IVT was significantly associated with very poor outcome (OR 2.22, 95% CI 1.05 to 4.73, p=0.04) and sICH (OR 3.44, 95% CI 1.18 to 10.07, p=0.02). Successful recanalization, age, and ASPECTS were associated with good functional outcome. Conclusions Bridging IVT in patients with low ASPECTS was associated with very poor functional outcome and an increased risk of sICH. The benefit of this treatment should therefore be carefully weighed in such scenarios. Further randomized controlled trials are required to validate our findings.
18 July 2019 in Journal of NeuroInterventional Surgery
Background Rapid development in endovascular aneurysm therapy continuously drives demand for suitable neurointerventional training opportunities. Objective To investigate the value of an integrated modular neurovascular training environment for aneurysm embolization using additively manufactured vascular models. Methods A large portfolio of 30 patient-specific aneurysm models derived from different treatment settings (eg, coiling, flow diversion, flow disruption) was fabricated using additive manufacturing. Models were integrated into a customizable neurointerventional simulator with interchangeable intracranial and cervical vessel segments and physiological circuit conditions (‘HANNES’; Hamburg ANatomic Neurointerventional Endovascular Simulator). Multiple training courses were performed and participant feedback was obtained using a questionnaire. Results Training for aneurysm embolization could be reliably performed using HANNES. Case-specific clinical difficulties, such as difficult aneurysm access or coil dislocation, could be reproduced. During a training session, models could be easily exchanged owing to standardized connectors in order to switch to a different treatment situation or to change from ‘treated’ back to ‘untreated’ condition. Among 23 participants evaluating hands-on courses using a five-point scale from 1 (strongly agree) to 5 (strongly disagree), HANNES was mostly rated as ‘highly suitable for practicing aneurysm coil embolization’ (1.78±0.79). Conclusion HANNES offers a wide variability and flexibility for case-specific hands-on training of intracranial aneurysm treatment, providing equal training conditions for each situation. The high degree of standardization offered may be valuable for analysis of device behavior or assessment of physician skills. Moreover, it has the ability to reduce the need for animal experiments.
9 November 2020 in Journal of NeuroInterventional Surgery
Background Patients presenting with large baseline infarctions are often excluded from mechanical thrombectomy (MT) due to uncertainty surrounding its effect on outcome. We hypothesized that computed tomography perfusion (CTP)-based selection may be predictive of functional outcome in low Alberta Stroke Program Early CT Score (ASPECTS) patients. Methods This was a double-center, retrospective analysis of patients presenting with ASPECTS≤5 who received multimodal admission CT imaging between May 2015 and June 2020. The predicted ischemic core (pCore) was defined as a reduction in cerebral blood flow (rCBF), while mismatch volume was defined using time to maximum (Tmax). The pCore perfusion mismatch ratio (CPMR) was also calculated. These parameters (pCore, mismatch volume, and CPMR), as well as a combined radiological score consisting of ASPECTS and collateral status (ASCO score), were tested in logistic regression and receiver operating characteristic (ROC) analyses. The primary outcome was favorable modified Rankin Scale (mRS) at discharge (≤3). Results A total of 113 patients met the inclusion criteria. The median ischemic core volume was 74.1 mL (IQR 43.8–121.8). The ASCO score was associated with favorable outcome at discharge (aOR 3.7, 95% CI 1.8 to 10.7, P=0.002), while no association was observed for the CTP parameters. A model including the ASCO score also had significantly higher area under the curve (AUC) values compared with the CTP-based model (0.88 vs 0.64, P=0.018). Conclusions The ASCO score was superior to the CTP-based model for the prediction of good functional outcome and could represent a quick, practical, and easily implemented method for the selection of low ASPECTS patients most likely benefit from MT.
6 February 2018 in PLOS ONE
Flow disruption achieved by braided intrasaccular implants is a novel treatment strategy for cerebrovascular aneurysms. We hypothesized that the degree of intra-aneurysmal flow disruption can be quantified in vitro and is influenced by device position across the aneurysm neck. We tested this hypothesis using the Medina® Embolization Device (MED). Ten different patient-specific elastic vascular models were manufactured. Models were connected to a pulsatile flow circuit, filled with a blood-mimicking fluid and treated by two operators using a single MED. Intra-aneurysmal flow velocity was measured using conventional and high-frequency digital subtraction angiography (HF-DSA) before and after each deployment. Aneurysm neck coverage by the implanted devices was assessed with flat detector computed tomography on a three-point Likert scale. A total of 80 individual MED deployments were performed by the two operators. The mean intra-aneurysmal flow velocity reduction after MED implantation was 33.6% (27.5–39.7%). No significant differences in neck coverage (p = 0.99) or flow disruption (p = 0.84) were observed between operators. The degree of flow disruption significantly correlated with neck coverage (ρ = 0.42, 95% CI: 0.21–0.59, p = 0.002) as well as with neck area (ρ = -0,35, 95% CI: -0.54 –-0.13, p = 0.024). On multiple regression analysis, both neck coverage and total neck area were independent predictors of flow disruption. The degree of intra-aneurysmal flow disruption after MED implantation can be quantified in vitro and varies considerably between different aneurysms and different device configurations. Optimal device coverage across the aneurysm neck improves flow disruption and may thus contribute to aneurysm occlusion.
10 February 2018 in Journal of NeuroInterventional Surgery
Objective To evaluate multiparametric MRI including non-contrast and contrast-enhanced morphological and angiographic techniques for intracranial aneurysms treated with the single-layer Woven EndoBridge (WEB) embolization system applying simultaneous digital subtraction angiography (DSA) as the reference of standard. Materials and methods We retrospectively identified all patients with incidental and acute ruptured intracranial aneurysms treated with a WEB device (WEB SL and WEB SLS) between March 2014 and June 2016 in our neurovascular center with early (within 7 days) postinterventional multiparametric MRI as well as mid-term (5–8 months) follow-up MRI and DSA available. Occlusion rates were recorded both in DSA and MR angiography (MRA). In MRI, signal intensities within the WEB as well as in the occluded dome distal to the WEB, if present, were measured by region-of-interest (ROI) analysis. Results Twenty-five patients fulfilled the inclusion criteria. Rates of complete/adequate occlusion at mid-term follow-up were 84% with both MRA and DSA. A strong signal loss within the WEB was observed in all MR sequences at initial and follow-up examinations. ROI analysis did not reveal significant differences in non-contrast (P=0.946) and contrast-enhanced imaging (P=0.377). A T1-hyperintense thrombus in the non-WEB-carrying dome was a frequent observation. Conclusions Signal intensity measurements in multiparametric MRI suggest that neither contrast-enhanced MRA nor morphological sequences are capable of revealing reliable information on the WEB lumen, presumably due to radio frequency shielding. MRI is therefore not suitable for confirming complete thrombus formation within the WEB.