Bulat Sh. Minasov

Bulat Sh. Minasov

Auto-generated profile, based on publicly available information

Bulat Sh. Minasov

Bashkir State Medical University

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2025 in N.N. Priorov Journal of Traumatology and Orthopedics
Verified
Journal Article
Open access
PDF file
BMBulat Sh. Minasov
Bulat Sh. Minasov
RYRasul R. Yakupov
Rasul R. Yakupov
VAVladislav N. Akbashev
Vladislav N. Akbashev
ABAzat R. Bilyalov
Azat R. Bilyalov
TMTimur B. Minasov
Timur B. Minasov
АААхмельдинова Айгуль Абузаровна
Ахмельдинова Айгуль Абузаровна
BACKGROUND: The increasing number of knee arthroplasty procedures and associated complications underscores the need for the implementation of technologies that enhance the precision of implant component positioning and improve functional outcomes. AIM: This study aimed to assess the precision of robotic knee arthroplasty in comparison with the manual technique based on clinical, radiological, and stabilometric data. METHODS: This cohort-controlled interventional single-center prospective randomized open-label study included 60 patients (aged 18–75 years) with stage III knee osteoarthritis. The patients were randomly assigned to the robotic arthroplasty group (30 individuals) or the manual arthroplasty group (30 individuals). Evaluation was performed 6 months postoperatively using clinical (VAS, ROM), radiological (LDFA, MPTA, rotational parameters), and stabilometric indicators. High-precision scales and 3D modeling were used to analyze the mass of the cement mantle. RESULTS: The robotic technique demonstrated superiority in the precision of component positioning: deviations of less than 1° in LDFA and MPTA were recorded in 93% and 66% of patients, respectively (compared with 23% and 9.4% in the manual technique group). The mean range of motion was 109° versus 106.2°, and the VAS pain score was 3.7 versus 4.2. The robotic technique ensured lower variability in cement mass and cement mantle thickness. CONCLUSION: Robotic arthroplasty surpasses the manual technique in terms of component positioning precision, cement mass distribution, and functional outcomes. Despite the absence of statistically significant differences (p 0.05), the observed trends in favor of the robotic approach render it preferable for widespread clinical application.