27 May 2022 in Journal of Orthopaedic Research
Radiostereometic analysis (RSA) is an accurate method for rigid body pose (position and orientation) in three‐dimensional space. Traditionally, RSA is based on insertion of periprosthetic tantalum markers and manual implant contour selection which limit clinically application. We propose an automated image registration technique utilizing digitally reconstructed radiographs (DRR) of computed tomography (CT) volumetric bone models (autorsa‐bone) as a substitute for tantalum markers. Furthermore, an automated synthetic volumetric representation of total knee arthroplasty implant models (autorsa‐volume) to improve previous silhouette‐projection methods (autorsa‐surface). As reference, we investigated the accuracy of implanted tantalum markers (marker) or a conventional manually contour‐based method (mbrsa) for the femur and tibia. The data are presented as mean (standard deviation). The autorsa‐bone method displayed similar accuracy of −0.013 (0.075) mm compared to the gold standard method (marker) of −0.013 (0.085). The autorsa‐volume with 0.034 (0.106) mm did not markedly improve the autorsa‐surface with 0.002 (0.129) mm, and none of these reached the mbrsa method of −0.009 (0.094) mm. In conclusion, marker‐free RSA is feasible with similar accuracy as gold standard utilizing DRR and CT obtained volumetric bone models. Furthermore, utilizing synthetic generated volumetric implant models could not improve the silhouette‐based method. However, with a slight loss of accuracy the autorsa methods provide a feasible automated alternative to the semi‐automated method.
3 February 2022 in Archives of orthopaedic and trauma surgery
21 April 2024 in Knee Surgery, Sports Traumatology, Arthroscopy
Purpose: The pivot‐shift test is used to clinically assess knee instability in patients with anterior cruciate ligament (ACL) lesions; however, it has low interobserver reliability. Dynamic radiostereometry (dRSA) is a highly precise and noninvasive method for the objective evaluation of joint kinematics. The purpose of this study was to quantify precise knee kinematics during a pivot‐shift test using dRSA imaging.Method: Eight human donor legs, including hemipelvises, were evaluated. Arthroscopic intervention was performed inducing ligament lesions in the ACL, and anterolateral ligament (ALL) section was performed as a capsular incision. The pivot‐shift test was recorded with dRSA on knees with intact ligaments, ACL‐deficient and ACL + ALL‐deficient knees.Results: A pivot‐shift pattern was identifiable after ligament lesion, as a change in tibial posterior drawer velocity from 7.8 mm/s (95% CI: 3.7; 11.9) in ligament intact knees to 30.4 mm/s (95% CI 23.0; 38.8) after ACL lesion to 35.1 mm/s (95% CI 23.4; 46.7) after combined ACL‐ALL lesion. The anterior‐posterior drawer excursion increased from 2.8 mm (95% CI 2.1; 3.4) in ligament intact knees to 7.2 mm (95% CI 5.5; 8.9) after ACL lesion to 7.6 mm (95% CI 5.5; 9.8) after combined lesion. A statistically significant increase in tibial external rotation towards the end of the pivot‐shift motion was observed when progressing from intact to ACL + ALL‐deficient knees (p < 0.023).Conclusion: This experimental study demonstrates the feasibility of dRSA to objectively quantify the kinematic laxity patterns of the knee during the pivot‐shift test. The dynamic parameters obtained through dRSA revealed the kinematic changes from ACL to combined ACL‐ALL ligament lesion.Level of Evidence: Not applicable.
17 December 2025 in Knee Surgery, Sports Traumatology, Arthroscopy