Andreas Lindner

Andreas Lindner

Auto-generated profile, based on publicly available information

Andreas Lindner

Department of Pediatric Surgery, Dr. von Hauner Children's Hospital, Ludwig-Maximilians-University of Munich, Lindwurmstr.4, 80337 Munich, Germany

Research Focus & Metrics

Academic Career Length

5Years (2022-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 December 2022 in Journal of Pediatric Surgery
Verified
Journal Article
Closed access
PDF file
NWNora Weisser
Nora Weisser
JKJulia Küppers
Julia Küppers
ALAndreas Lindner
Andreas Lindner
MHMartina Heinrich
Martina Heinrich
PZPetra Zimmermann
Petra Zimmermann
Oliver J. MuenstererOliver J. Muensterer
Oliver J. Muensterer

10 February 2025 in Journal of Pediatric Surgery
Verified
Journal Article
Open access
KHKayoung Heo
Kayoung Heo
EGEric Greaney
Eric Greaney
JHJulia Haehl
Julia Haehl
CSChelsea Stunden
Chelsea Stunden
ALAndreas Lindner
Andreas Lindner
SJShahrzad Joharifard
Shahrzad Joharifard
Inguinal hernia is a common childhood pathology, making inguinal hernia repair (IHR) a key pediatric surgical procedure. Surgical success relies heavily on knowledge of groin anatomy, and both open and laparoscopic approaches require considerable repetition to master. As surgical simulators have been shown to improve performance for other surgical procedures, we developed a combined open and laparoscopic pediatric IHR simulator-named POLISHeR-to train residents, fellows, and practicing surgeons in both types of repair. A CT scan of a 7-year-old was scaled down to create a virtual 3D model of a 2-year-old using our validated protocol for anatomical modelling. Physical replicas of the pelvis, abdominal wall, aorta, and inferior vena cava were 3D-printed to create a life-size unisex base for open and laparoscopic IHR, while a small mobile unisex base was 3D-printed for open IHR. We recruited six experienced surgeons and trainees to pilot the face validity of POLISHeR. After multiple iterations, we successfully developed a modular 3D-printed simulator for open and laparoscopic IHR. Printing the life-size base cost $331.69 USD, whereas the small base cost $17.54. An open modular cartridge cost $9.92 for females and $14.21 for males, whereas replacement parts cost under $1.30. A laparoscopic modular cartridge cost $6.16 for females and $10.91 for males, whereas replacement parts cost $0.28. Pilot study participants provided encouraging feedback with respect to POLISHER's face validity. Our low-cost simulator holds promise for enhancing training for pediatric IHR. Our next step is to conduct validation trials for trainees and practicing surgeons in both well-resourced and resource-limited settings. Not applicable.

29 January 2026 in Journal of Pediatric Surgery
Verified
Journal Article
Open access
PMPeter R.A. Malik
Peter R.A. Malik
JHJulia Haehl
Julia Haehl
RLRachel Livergant
Rachel Livergant
LSLukas Shum-Tim
Lukas Shum-Tim
KHKayoung Heo
Kayoung Heo
SJShahrzad Joharifard
Shahrzad Joharifard
Pediatric inguinal hernia repair (PIHR) is a common procedure performed using either open or laparoscopic techniques. Both approaches require detailed anatomical knowledge and specialized training. To address these training needs, we developed a low-cost, 3D-printed Pediatric Open and Laparoscopic Integrated Simulator for Inguinal Hernia Repair (POLISHeR). This study aimed to validate POLISHeR as a simulation tool for essential PIHR skills. Experienced pediatric surgeons and surgical trainees performed simulated PIHR using POLISHeR. Participants evaluated the simulator's face and content validity using a 5-point Likert scale. Two experienced pediatric surgeons assessed video-recorded simulations using procedure (PCL) and error (ECL) checklists. An Entrustable Professional Activity (EPA) scale measured participants' competence. Construct validity was assessed by comparing expert and trainee performance using the Mann-Whitney U test. Twenty-six participants completed simulations (open: n=11; laparoscopic: n=15), including 14 expert pediatric surgeons (open: n=5; laparoscopic: n=9). In laparoscopic PIHR, trainees made significantly more errors (p < 0.001), completed fewer key steps (p < 0.001), and received lower EPA scores (p < 0.001) than experts. In open PIHR, trainees made more errors (p = 0.03), had lower EPA scores (p = 0.05), and received lower PCL scores (p = 0.410), though not statistically significant. Experts reported strong anatomical realism and accurate step representation. POLISHeR demonstrates strong face, content, and construct validity. It effectively differentiates between expert and trainee performance and represents an affordable, practical tool for teaching and evaluating PIHR skills.

11 April 2025 in Pediatric Pulmonology
Verified
Journal Article
Open access
FAF.‐X. Anzinger
F.‐X. Anzinger
THT. J. Hashagen
T. J. Hashagen
PPP. Palaniappan
P. Palaniappan
ALA. Lindner
A. Lindner
MRM. Riboldi
M. Riboldi
OMO. J. Muensterer
O. J. Muensterer
Background: In recent years, digital chest tube drainage systems have been introduced. Limited studies address their benefits and risks in pediatric patients, particularly neonates. This study compares a three‐chamber chest drainage system with a digital system using a high‐fidelity 3D‐printed model.Methods: We conducted direct measurements and 3D‐printed model tests with both systems at different suction pressures (−1 to −20 cmH2O) to assess the actual pressures. The effects of siphon and automatic flushes in the digital system were also studied.Results: At −20 and −10 cmH2O, significant differences were found between the digital and analog systems in direct and model measurements. The analog system became unreliable below −10 cmH2O. For the digital system, most measurements remained within the set pressures, with outliers up to −30 cmH2O due to regular flushing.Conclusion: This experimental study evaluates the suitability of digital drainage systems for the pediatric and neonatal populations. Our model demonstrated reliable simulation of thoracic conditions, making it a useful tool for pre‐clinical testing where patient testing may be limited. Both systems yielded satisfactory results at −20 and −10 cmH2O, but the digital system showed greater flexibility, maintaining pressures as low as −5 cmH2O. The analog system was consistent but less adaptable, which may limit its use in dynamic situations. The digital system's ability to simulate more flexible scenarios offers potential clinical advantages, though further investigation is needed to assess its impact on neonatal safety. The increase in suction during flushing may pose a risk for neonatal patients.

11 February 2026 in Seminars in Pediatric Surgery
Verified
Journal Article
Open access
CRCharlotte Reich
Charlotte Reich
YSYannick Schmidt
Yannick Schmidt
KKKarina Khakim
Karina Khakim
ALAndreas Lindner
Andreas Lindner
NKNomin Krespach
Nomin Krespach
DWDanielle S Wendling-Keim
Danielle S Wendling-Keim
Retained esophageal button batteries (BBs) cause significant morbidity in children. Current guidelines recommend oral honey administration in children over 1 year and esophageal irrigation with 0.25 % acetic acid (ACA) after BB removal, but supporting evidence is limited. We aimed to develop a dynamic in vitro esophageal model to evaluate these interventions. Our novel model consisted of fresh porcine oesophagi suspended in an environment simulating body temperature, peristalsis, and saline perfusion. BBs or sham BBs were placed in the oesophagus. Honey was administered at specific intervals after BB insertion. After BB removal, the lesions were washed with ACA or buffer solution. Paraffin slides were stained with hematoxylin and eosin (HE) to quantify the ulceration. The mean pH was significantly lower in samples exposed to honey (p≤0.0001) and the voltage discharge was reduced with honey as well (p≤0.0001). Application of honey resulted in macroscopically smaller ulcers than in untreated oesophagi. HE staining confirmed the macroscopic results with significantly reduced ulcers with honey application (p < 0.009). Irrigation with ACA had no effect. We developed a dynamic in vitro model of oesophageal button battery ingestion by including peristalsis, body temperature, an upright lumen and saline perfusion. Our data supports the recommendations that oral honey application before endoscopic battery removal protects the mucosa after oesophageal BB retention, whereas ACA irrigation at the time of BB removal showed no effect in this study.

19 November 2024
Verified
Preprint
Open access
FAF-X. Anzinger
F-X. Anzinger
THT. J. Hashagen
T. J. Hashagen
PPP. Palaniappan
P. Palaniappan
ALAndreas Lindner
Andreas Lindner
MRM. Riboldi
M. Riboldi
OMO. J. Muensterer
O. J. Muensterer
Background: In recent years, digital thoracic drainage systems have been introduced. Limited studies address the benefits and risks in pediatric patients. We compared analog and digital systems using a high-fidelity 3D-printed phantom. Methods: Direct measurements as well as measurements on a 3D-printed phantom were conducted employing a digital and analog system for different suction pressures (-1 to -20 cmH 2 O). The impact of a siphon and automatic flushes of the digital system were studied. Results: At pressure settings of -20 and -10 cmH 2 O, direct and phantom measurements yielded significantly different results for the digital compared to the analog system. Set pressures below -10 cmH 2 O in the analog drainage system were unreliable. For the digital system, the majority of measured points fell within the chosen settings. There were statistical outliers up to -30 cmH 2 O attributed to the regular flushing performed by the system. Conclusion: This is the first experimental study objectifying the suitability of digital drainage systems for the pediatric and neonatal population. Our phantom produced accurate results where tests on patients are not possible. At suction pressures of -20 and -10 cmH 2 O the digital and the analog drainage system yield satisfactory results. The digital system was able to maintain pressures as low as -5 cmH 2 O. The analog drainage system is less flexible but remains a reliable tool for experienced users. The digital drainage system allows more freedom and can increase patient safety by neutralizing obstructions or a siphon. The increase in suction during flushing may pose a risk for neonatal patients.