1 November 2017 in Energy Conversion and Management
5 May 2016 in IEEE Transactions on Industrial Electronics
A direct three-phase ac-ac matrix converter for inductive power transfer (IPT) systems with soft-switching operation is introduced. The proposed topology is expected to have a high reliability and extended lifetime due to the soft-switching operation and elimination of short-life electrolytic capacitors. The soft-switching operation will also reduce switching stress, switching loss, and electromagnetic interference of the converter. A variable-frequency control strategy based on the energy-injection and free-oscillation technique is used to regulate the resonant current, the resonant voltage, and the output power. With the use of reverse-blocking switches, the proposed converter can be built with a reduced number of switches (only seven), which will consequently increase the reliability and efficiency and reduce the cost of the converter. The converter operates in eight modes, which are described in detail. With the use of the proposed converter as the primary converter, simulation analysis and experimental implementations on a case study IPT system show that the current regulation control method can fully regulate the output current and output power around user-defined reference values, thus making it suitable for dynamic IPT applications, where the system has inherent variations.
27 July 2016 in IEEE Transactions on Industrial Electronics
In order to reduce the influence of the grid harmonic currents and voltages, harmonic compensation is regularly implemented for a grid-tied inverter. In this study, a new topology of a higher order power filter for single-phase grid-tied voltage-source inverters, named L(LCL) 2 , is presented. The subscript is added to the name to prevent confusion with the LLCL filter. In the proposed design, the inverter side inductance is divided into three parts, and the grid side inductor is removed. Also, an additional resonant branch at the double of the switching frequency is added to the traditional LLCL filter to attenuate high-frequency harmonics. The overall inductance of the recommended filter is smaller than the LLCL filter. A comparative study and discussions on the subject of the traditional LLCL filter and the proposed L(LCL) 2 filter have been conducted and assessed through an experimental hardware implementation on a 700 W, 120 V/60 Hz single-phase grid-tied inverter. Furthermore, a straightforward engineering design benchmark is suggested to discover parameters of the L(LCL) 2 filter. Moreover, stability analysis, loss analysis and an optimization of the L(LCL) 2 filter parameters have been conducted in this study. The analysis shows that in comparison with the LLCL filter, the L(LCL) 2 filter not only has lower voltage drop and less total inductor size, but also has improved performance in decreasing high-order current harmonics.