5 August 2022 in IEEE Open Journal of Instrumentation and Measurement
Patients with bladder dysfunction are unable to perceive bladder volume and urinate spontaneously, and hence usually require catheterization. Personalized catheterization can effectively reduce the risk of urinary tract infections caused by catheterization. Electrical impedance tomography (EIT) can provide an effective tool for personalized catheterization by monitoring bladder volume. This study exploits the fringe effect of a 2D EIT sensor to derive the 3D volumetric information about bladder and improve the measurement consistency and accuracy of bladder volume under varied urine conductivities. The EIT sensor is optimized regarding the specified application of fringe effect. The parameters to be optimized include the electrode arrangement, the distance of electrode plane from bladder bottom, and the number of electrodes. Three evaluation criteria are proposed for the optimization. Simulation and experiment confirm the feasibility of the fringe effect-based method for bladder volume measurement, and the performances of the optimized sensor are illustrated. It is concluded that the fringe effect-based method has a better measurement consistency and accuracy against urine conductivity than the widelyused global impedance-based method, and hence provides a new promising alternative for bladder volume measurement.
19 May 2023 in IEEE Transactions on Instrumentation and Measurement
Clinically, dynamic monitoring of bladder volume is of great significance for patients with bladder diseases. This paper proposes a method for the continuous monitoring of bladder volume by 3D electrical impedance tomography (EIT). To facilitate convenient installation and maintenance for patients, a single-layer half-circle EIT sensor is proposed and designed to be attached at the top of full bladder for 3D imaging, based on fringe field sensing. By incorporating the simple prior knowledge of the approximate position and maximum extension region of a full bladder in abdomen, a dedicated sparse representation algorithm was proposed to alleviate the ill-posedness of 3D reconstruction and improve the image quality. Bladder volume is finally estimated based on the 3D image with improved accuracy. Effectiveness of the proposed method is verified by simulation and human trials. Results show that this method is able to reconstruct 3D image of bladder, and the estimation errors of volume are less than 8% in the human trials, which is accurate enough for patients nursing. This provides a promising alternative for the dynamic monitoring of bladder volume.