The mechanism of graphene delamination from a Pt catalyst growth surface with electrochemical methods is studied. After a water intercalation step, an electrochemical graphene delamination process is done with a variety of different electrolytes. It is shown that (hydrogen or oxygen) bubble formation is not the main driving force to decouple graphene from its catalyst growth substrate. Ion intercalation is identified as the primary component for a fast graphene delamination process from its catalytic growth substrate. When the Pt/graphene sample is negatively charged, cations will intercalate, assuming they do not reduce within the electrochemical window of the solvent. This cation intercalation does result in graphene delamination. In the same way, anions intercalate in positively charged Pt/graphene samples when they do not react within the electrochemical window of the solvent. Furthermore, it is shown that applying a potential is sufficient (current is not needed) to induce ion intercalation and, as a result, graphene delamination. These findings open the door to avoid Na+ or K+ contamination introduced during currently described electrochemical graphene delamination. Alternative electrolytes (i.e. ammonium hydroxide and tetraethylammonium hydroxide) are proposed, due to the absence of alkali contaminants and rapid cation intercalation to delaminate graphene.
11 December 2018 in ECS Journal of Solid State Science and Technology
The synthesis of graphene using chemical vapor deposition on platinum surfaces is discussed. The crystalline nature of the platinum substrates as well as the graphene growth conditions play a key role to yield monolayer graphene with low defectivity. The need for template wafers with a single Pt orientation emerges due to graphene overgrowth on untextured polycrystalline Pt foils. Single-crystalline Pt foils can be obtained after long annealing steps. However, these Pt foils remain rough and are therefore less suitable during subsequent graphene transfer procedures. On the other hand, highly oriented platinum thin films avoid the overgrowth issues but result in differing nucleation phenomena on different oriented grains. An optimized graphene growth template is found in Al2O3(0001)/Pt(111), which is more than one order of magnitude flatter compared to the annealed Pt(111) foils and serves as an ideal catalyst to grow graphene grains exceeding 7 mm in diameter.
New diglycolamide extractants with varying alkyl chains were synthesized and their selectivity in americium separation processes was evaluated through extraction experiments. Speciation was used to elucidate the formed complexes.
Selectively separating Am(III) from nuclear waste streams is an extremely challenging task due to the presence of the trivalent lanthanides and Cm(III). 1,10-Phenanthroline ligands decorated with 1,2,4-triazines or 1,2,3-triazoles have emerged as promising extractants for achieving such separation. In this article, a new robust synthetic pathway towards the hydrophilic, CHON compliant bistriazoylphenanthroline ligand BTrzPhen-tetraol is reported. BTrzPhen-tetraol was synthesised both as the hydrochloride and as a free base with overall yields of 66% and 48%, respectively. The ligand demonstrated excellent solubility and stability in dilute nitric acid solutions, with no observable decomposition after three days in 0.5 mol L−1 HNO3 at 50 °C. Additionally, it exhibited rapid stripping kinetics for Am(III) and Eu(III). Liquid–liquid extraction experiments conducted with BTrzPhen-tetraol, TODGA, and radiotracers of Am(III), Cm(III), and Eu(III) yielded maximum Eu(III)/Am(III) and Cm(III)/Am(III) separation factors of 84 and 2.4, respectively, at 0.26 mol L−1 HNO3. Notably, the separation factors achieved with BTrzPhen-tetraol are comparable to those of existing systems. While only a minor influence of the BTrzPhen concentration on the distribution ratios of Am and Cm was observed under the given conditions, these results highlight the effectiveness of hydrophilic BTrzPhen ligands for selective americium stripping and encourage further optimisation to enhance performance.
In nuclear reprocessing, hydrolytic and radiolytic stability of ligands, extractants, diluents and solvents is of particular importance. The strength of extraction systems can only be fully exploited when process conditions are predictable and essential molecules, which are in close proximity to radioactive isotopes, are resistant to the radiation. During the development of novel extraction systems, testing of the radiolytic stability is often evaluated by exposing the molecules to high energetic gamma rays. In this work, the influence of the source of gamma rays is evaluated. TODGA was irradiated from 0–500 kGy using different sources of gamma rays, and its degradation was followed using UPLC-HRMS. Pool-type gamma irradiation facilities BRIGITTE B (Co-60) and GEUSE II (spent nuclear fuel) at SCK CEN were employed to serve as gamma sources. In this work, it is found that there is no significant influence on TODGA degradation which can be attributed to the origin of the gamma source.