Geumbee Lee

Geumbee Lee

Auto-generated profile, based on publicly available information

Geumbee Lee

Querrey Simpson Institute for Bioelectronics, Northwestern University, Evanston, IL 60208, USA

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
24 February 2023 in Science Advances
Verified
Journal Article
Closed access
JSJoseph W. Song
Joseph W. Song
HRHanjun Ryu
Hanjun Ryu
Wubin BaiWubin Bai
Wubin Bai
Zhaoqian XieZhaoqian Xie
Zhaoqian Xie
Abraham Vázquez-GuardadoAbraham Vázquez-Guardado
Abraham Vázquez-Guardado
JRJohn A. Rogers
John A. Rogers
Chronic wounds, particularly those associated with diabetes mellitus, represent a growing threat to public health, with additional notable economic impacts. Inflammation associated with these wounds leads to abnormalities in endogenous electrical signals that impede the migration of keratinocytes needed to support the healing process. This observation motivates the treatment of chronic wounds with electrical stimulation therapy, but practical engineering challenges, difficulties in removing stimulation hardware from the wound site, and absence of means to monitor the healing process create barriers to widespread clinical use. Here, we demonstrate a miniaturized wireless, battery-free bioresorbable electrotherapy system that overcomes these challenges. Studies based on a splinted diabetic mouse wound model confirm the efficacy for accelerated wound closure by guiding epithelial migration, modulating inflammation, and promoting vasculogenesis. Changes in the impedance provide means for tracking the healing process. The results demonstrate a simple and effective platform for wound site electrotherapy.

7 October 2022 in Science Advances
Verified
Journal Article
Open access
GLGeumbee Lee
Geumbee Lee
EREmily Ray
Emily Ray
HYHong-Joon Yoon
Hong-Joon Yoon
SGSabrina Genovese
Sabrina Genovese
YCYeon Sik Choi
Yeon Sik Choi
JRJohn A. Rogers
John A. Rogers
Local electrical stimulation of peripheral nerves can block the propagation of action potentials, as an attractive alternative to pharmacological agents for the treatment of acute pain. Traditional hardware for such purposes, however, involves interfaces that can damage nerve tissue and, when used for temporary pain relief, that impose costs and risks due to requirements for surgical extraction after a period of need. Here, we introduce a bioresorbable nerve stimulator that enables electrical nerve block and associated pain mitigation without these drawbacks. This platform combines a collection of bioresorbable materials in architectures that support stable blocking with minimal adverse mechanical, electrical, or biochemical effects. Optimized designs ensure that the device disappears harmlessly in the body after a desired period of use. Studies in live animal models illustrate capabilities for complete nerve block and other key features of the technology. In certain clinically relevant scenarios, such approaches may reduce or eliminate the need for use of highly addictive drugs such as opioids.

23 December 2022 in Science Advances
Verified
Journal Article
Open access
HYHong-Joon Yoon
Hong-Joon Yoon
GLGeumbee Lee
Geumbee Lee
JKJin-Tae Kim
Jin-Tae Kim
JYJae-Young Yoo
Jae-Young Yoo
HLHaiwen Luan
Haiwen Luan
JRJohn A. Rogers
John A. Rogers
Recently reported winged microelectronic systems offer passive flight mechanisms as a dispersal strategy for purposes in environmental monitoring, population surveillance, pathogen tracking, and other applications. Initial studies indicate potential for technologies of this type, but advances in structural and responsive materials and in aerodynamically optimized geometries are necessary to improve the functionality and expand the modes of operation. Here, we introduce environmentally degradable materials as the basis of 3D fliers that allow remote, colorimetric assessments of multiple environmental parameters—pH, heavy metal concentrations, and ultraviolet exposure, along with humidity levels and temperature. Experimental and theoretical investigations of the aerodynamics of these systems reveal design considerations that include not only the geometries of the structures but also their mass distributions across a range of bioinspired designs. Preliminary field studies that rely on drones for deployment and for remote colorimetric analysis by machine learning interpretation of digital images illustrate scenarios for practical use.

25 June 2023 in Advanced Science
Verified
Journal Article
Open access
GLGeumbee Lee
Geumbee Lee
MDMark D. Does
Mark D. Does
RARaudel Avila
Raudel Avila
JKJuyeon Kang
Juyeon Kang
KHKevin D. Harkins
Kevin D. Harkins
John A. RogersJohn A. Rogers
John A. Rogers
Magnetic resonance imaging (MRI) is widely used in clinical care and medical research. The signal‐to‐noise ratio (SNR) in the measurement affects parameters that determine the diagnostic value of the image, such as the spatial resolution, contrast, and scan time. Surgically implanted radiofrequency coils can increase SNR of subsequent MRI studies of adjacent tissues. The resulting benefits in SNR are, however, balanced by significant risks associated with surgically removing these coils or with leaving them in place permanently. As an alternative, here the authors report classes of implantable inductor–capacitor circuits made entirely of bioresorbable organic and inorganic materials. Engineering choices for the designs of an inductor and a capacitor provide the ability to select the resonant frequency of the devices to meet MRI specifications (e.g., 200 MHz at 4.7 T MRI). Such devices enhance the SNR and improve the associated imaging capabilities. These simple, small bioelectronic systems function over clinically relevant time frames (up to 1 month) at physiological conditions and then disappear completely by natural mechanisms of bioresorption, thereby eliminating the need for surgical extraction. Imaging demonstrations in a nerve phantom and a human cadaver suggest that this technology has broad potential for post‐surgical monitoring/evaluation of recovery processes.

18 November 2022 in Advanced Healthcare Materials
Verified
Journal Article
Open access
JSJaeho Shin
Jaeho Shin
HWHeling Wang
Heling Wang
KKKyeongha Kwon
Kyeongha Kwon
DODiana Ostojich
Diana Ostojich
ZCZach Christiansen
Zach Christiansen
John A. RogersJohn A. Rogers
John A. Rogers
Accurate measurements of skin hydration are of great interest to dermatological science and clinical practice. This parameter serves as a relevant surrogate of skin barrier function, a key representative benchmark for overall skin health. The skin hydration sensor (SHS) is a soft, skin‐interfaced wireless system that exploits a thermal measurement method, as an alternative to conventional impedance‐based hand‐held probes. This study presents multiple strategies for maximizing the sensitivity and reliability of this previously reported SHS platform. An in‐depth analysis of the thermal physics of the measurement process serves as the basis for structural optimizations of the electronics and the interface to the skin. Additional engineering advances eliminate variabilities associated with manual use of the device and with protocols for the measurement. The cumulative effect is an improvement in sensitivity by 135% and in repeatability by 36% over previously reported results. Pilot trials on more than 200 patients in a dermatology clinic validate the practical utility of the sensor for fast, reliable measurements.

18 December 2025 in Advanced Functional Materials
Verified
Journal Article
Open access
JPJeonghwan Park
Jeonghwan Park
HAHak-Young Ahn
Hak-Young Ahn
MSMinho Seong
Minho Seong
TKTaehoon Kim
Taehoon Kim
YZYulin Zhou
Yulin Zhou
John A. RogersJohn A. Rogers
John A. Rogers
Conventional strategies for the management of acute pain have significant limitations. Pharmaceutical approaches carry risks for addiction and misuse. Standard implantable devices require secondary surgeries for removal and physical tethers to external systems for power and control. Recent work on bioresorbable electrical stimulators overcomes certain of these drawbacks, but existing versions still depend on transcutaneous leads. Here, we introduce a platform that employs thermal mechanisms for nerve block to bypass some of these limitations. The system integrates both a Joule heating element and a resistive temperature sensor in a soft cuff structure as a nerve interface, in which most of the materials are bioresorbable over a clinically relevant timeframe. This design enables precise control of nerve temperature within a safe range (≤45°C) for effective nerve block through a feedback‐guided strategy that continuously monitors temperature and adjusts current in real time. Options for wireless power delivery eliminate the need for external interfaces. Small animal model studies confirm the reversible and non‐invasive operation of this system. The results demonstrate effective suppression of compound nerve action potentials in response to thermal stimulation, with recovery of nerve conduction upon cooling. These findings highlight the potential of this platform as a safe and effective solution to acute pain management.