An occult foreign body may be retained in patient with small self-sealing wound and no decreased visual acuity without complete examination. Here we report a case of a retained occult ferrous iris foreign body detected incidentally during pterygium examination. A 69-year-old man presented to our ophthalmology department because of foreign body sensation and persistent redness in both eyes for 2 years. In the left eye, a pterygium, paracentral corneal opacity and a vertically oval pupil were observed. Ultrasound biomicroscopy and gonioscopy revealed a retained metallic-like foreign body partially embedded in the inferior peripheral iris. Pterygium surgery and the removal of the retained iris foreign body were performed simultaneously. No recurrent pterygium or residual foreign body was found during follow-up. A thorough history should be obtained and complete physical examination should be performed in patients with ocular self-sealing wounds to prevent missed intraocular foreign bodies, which may result in potential sight-threatening ocular complications.
Purpose: To identify baseline predictors of early submacular haemorrhage (SMH) displacement following intravitreal injection of C3F8, recombinant tissue plasminogen activator (rt-PA), and ranibizumab in patients with polypoidal choroidal vasculopathy (PCV). Methods: In this retrospective case-control study, swept-source OCT scans were analysed before and one week after treatment. SMH displacement was classified as incomplete (Group 1) or complete (Group 2) based on fundus photography and OCT. Clinical characteristics and OCT-derived parameters were evaluated for associations with displacement status. Results: Fifty-one eyes from 51 PCV patients were included. All eyes demonstrated some degree of SMH displacement after treatment, with 33 eyes showing incomplete displacement (residual SMH under the fovea: 80–768 μm) and 18 eyes showing complete displacement. Group 2 had better baseline visual acuity, and baseline LogMAR BCVA was negatively correlated with displacement grade. Group 2 also exhibited larger initial SMH volume and lower contrast-to-noise ratio (CNR), both associated with greater displacement. Although baseline PED volumes were similar, PED regression was more pronounced in Group 2. Conclusion: Complete SMH displacement was associated with better baseline vision, lower CNR, larger haemorrhage volume, and greater PED regression. Baseline BCVA, CNR, and SMH volume may serve as predictive factors for early SMH displacement following treatment.