30 March 2024 in EP Europace
Photoplethysmography- (PPG) based smartphone applications facilitate heart rate and rhythm monitoring in patients with paroxysmal and persistent atrial fibrillation (AF). Despite an endorsement from the European Heart Rhythm Association, validation studies in this setting are lacking. Therefore, we evaluated the accuracy of PPG-derived heart rate and rhythm classification in subjects with an established diagnosis of AF in unsupervised real-world conditions. Fifty consecutive patients were enrolled, 4 weeks before undergoing AF ablation. Patients used a handheld single-lead electrocardiography (ECG) device and a fingertip PPG smartphone application to record 3907 heart rhythm measurements twice daily during 8 weeks. The ECG was performed immediately before and after each PPG recording and was given a diagnosis by the majority of three blinded cardiologists. A consistent ECG diagnosis was exhibited along with PPG data of sufficient quality in 3407 measurements. A single measurement exhibited good quality more often with ECG (93.2%) compared to PPG (89.5%; P < 0.001). However, PPG signal quality improved to 96.6% with repeated measurements. Photoplethysmography-based detection of AF demonstrated excellent sensitivity [98.3%; confidence interval (CI): 96.7–99.9%], specificity (99.9%; CI: 99.8–100.0%), positive predictive value (99.6%; CI: 99.1–100.0%), and negative predictive value (99.6%; CI: 99.0–100.0%). Photoplethysmography underestimated the heart rate in AF with 6.6 b.p.m. (95% CI: 5.8 b.p.m. to 7.4 b.p.m.). Bland–Altman analysis revealed increased underestimation in high heart rates. The root mean square error was 11.8 b.p.m. Smartphone applications using PPG can be used to monitor patients with AF in unsupervised real-world conditions. The accuracy of AF detection algorithms in this setting is excellent, but PPG-derived heart rate may tend to underestimate higher heart rates.
6 August 2022 in European Journal of Cardiovascular Nursing
The aim of this TeleCheck-AF sub-analysis was to evaluate motivation and adherence to on-demand heart rate/rhythm monitoring app in patients with atrial fibrillation (AF). Patients were instructed to perform 60 s app-based heart rate/rhythm recordings 3 times daily and in case of symptoms for 7 consecutive days prior to teleconsultation. Motivation was defined as number of days in which the expected number of measurements (≥3/day) were performed per number of days over the entire prescription period. Adherence was defined as number of performed measurements per number of expected measurements over the entire prescription period. Data from 990 consecutive patients with diagnosed AF [median age 64 (57–71) years, 39% female] from 10 centres were analyzed. Patients with both optimal motivation (100%) and adherence (≥100%) constituted 28% of the study population and had a lower percentage of recordings in sinus rhythm [90 (53–100%) vs. 100 (64–100%), P < 0.001] compared with others. Older age and absence of diabetes were predictors of both optimal motivation and adherence [odds ratio (OR) 1.02, 95% coincidence interval (95% CI): 1.01–1.04, P < 0.001 and OR: 0.49, 95% CI: 0.28–0.86, P = 0.013, respectively]. Patients with 100% motivation also had ≥100% adherence. Independent predictors for optimal adherence alone were older age (OR: 1.02, 95% CI: 1.00–1.04, P = 0.014), female sex (OR: 1.70, 95% CI: 1.29–2.23, P < 0.001), previous AF ablation (OR: 1.35, 95% CI: 1.03–1.07, P = 0.028). In the TeleCheck-AF project, more than one-fourth of patients had optimal motivation and adherence to app-based heart rate/rhythm monitoring. Older age and absence of diabetes were predictors of optimal motivation/adherence.
21 June 2023 in JACC: Clinical Electrophysiology
20 September 2021 in Frontiers in Cardiovascular Medicine
Aims: This study aims to compare the performance of physicians to detect atrial fibrillation (AF) based on photoplethysmography (PPG), single-lead ECG and 12-lead ECG, and to explore the incremental value of PPG presentation as a tachogram and Poincaré plot, and of algorithm classification for interpretation by physicians.Methods and Results: Email invitations to participate in an online survey were distributed among physicians to analyse almost simultaneously recorded PPG, single-lead ECG and 12-lead ECG traces from 30 patients (10 in sinus rhythm (SR), 10 in SR with ectopic beats and 10 in AF). The task was to classify the readings as ‘SR', ‘ectopic/missed beats', ‘AF', ‘flutter' or ‘unreadable'. Sixty-five physicians detected or excluded AF based on the raw PPG waveforms with 88.8% sensitivity and 86.3% specificity. Additional presentation of the tachogram plus Poincaré plot significantly increased sensitivity and specificity to 95.5% (P < 0.001) and 92.5% (P < 0.001), respectively. The algorithm information did not further increase the accuracy to detect AF (sensitivity 97.5%, P = 0.556; specificity 95.0%, P = 0.182). Physicians detected AF on single-lead ECG tracings with 91.2% sensitivity and 93.9% specificity. Diagnostic accuracy was also not optimal on full 12-lead ECGs (93.9 and 98.6%, respectively). Notably, there was no significant difference between the performance of PPG waveform plus tachogram and Poincaré, compared to a single-lead ECG to detect or exclude AF (sensitivity P = 0.672; specificity P = 0.536).Conclusion: Physicians can detect AF on a PPG output with equivalent accuracy compared to single-lead ECG, if the PPG waveforms are presented together with a tachogram and Poincaré plot and the quality of the recordings is high.
30 September 2023 in European Heart Journal - Digital Health
The aim of this study is to determine the feasibility, detection rate, and therapeutic implications of large-scale smartphone-based screening for atrial fibrillation (AF). Subjects from the general population in Belgium were recruited through a media campaign to perform AF screening during 8 consecutive days with a smartphone application. The application analyses photoplethysmography traces with artificial intelligence and offline validation of suspected signals to detect AF. The impact of AF screening on medical therapy was measured through questionnaires. Atrial fibrillation was detected in the screened population (n = 60.629) in 791 subjects (1.3%). From this group, 55% responded to the questionnaire. Clinical AF [AF confirmed on a surface electrocardiogram (ECG)] was newly diagnosed in 60 individuals and triggered the initiation of anti-thrombotic therapy in 45%, adjustment of rate or rhythm controlling strategies in 62%, and risk factor management in 17%. In subjects diagnosed with known AF before screening, a positive screening result led to these therapy adjustments in 9%, 39%, and 11%, respectively. In all subjects with clinical AF and an indication for oral anti-coagulation (OAC), OAC uptake increased from 56% to 74% with AF screening. Subjects with clinical AF were older with more co-morbidities compared with subclinical AF (no surface ECG confirmation of AF) (P < 0.001). In subjects with subclinical AF (n = 202), therapy adjustments were performed in only 7%. Smartphone–based AF screening is feasible at large scale. Screening increased OAC uptake and impacted therapy of both new and previously diagnosed clinical AF but failed to impact risk factor management in subjects with subclinical AF. Subjects from the general population were recruited through a media campaign to perform AF screening with a smartphone application. The application analyses photoplethysmography traces with artificial intelligence and offline validation of suspected signals to detect AF. The number needed to screen to detect a new case of AF was 133. When AF is confirmed on a surface ECG, it is referred to as clinical AF. In all subjects with clinical AF and an elevated CHA2DS2-VASC score, OAC uptake increased from 56% to 74% with AF screening. Subclinical AF refers to AF that is not confirmed with a surface ECG, OAC uptake in this group increased from 15% to 18%. AF, atrial fibrillation; ECG, electrocardiogram; OAC, oral anti-coagulation; PPG, photoplethysmography.
9 January 2025 in JMIR Formative Research
Background: Consumer-oriented wearable devices (CWDs) such as smartphones and smartwatches have gained prominence for their ability to detect atrial fibrillation (AF) through proprietary algorithms using electrocardiography or photoplethysmography (PPG)–based digital recordings. Despite numerous individual validation studies, a direct comparison of interdevice performance is lacking. Objective: This study aimed to evaluate and compare the ability of CWDs to distinguish between sinus rhythm and AF. Methods: Patients exhibiting sinus rhythm or AF were enrolled through a cardiology outpatient clinic. The participants were instructed to perform heart rhythm measurements using a handheld 6-lead electrocardiogram (ECG) device (KardiaMobile 6L), a smartwatch-derived single-lead ECG (Apple Watch), and two PPG-based smartphone apps (FibriCheck and Preventicus) in a random sequence, with simultaneous 12-lead reference ECG as the gold standard. Results: A total of 122 participants were included in the study: median age 69 (IQR 61-77) years, 63.9% (n=78) men, 25% (n=30) with AF, 9.8% (n=12) without prior smartphone experience, and 73% (n=89) without experience in using a smartwatch. The sensitivity to detect AF was 100% for all devices. The specificity to detect sinus rhythm was 96.4% (95% CI 89.5%-98.8%) for KardiaMobile 6L, 97.8% (95% CI 91.6%‐99.5%) for Apple Watch, 98.9% (95% CI 92.5%‐99.8%) for FibriCheck, and 97.8% (95% CI 91.5%‐99.4%) for Preventicus (P=.50). Insufficient quality measurements were observed in 10.7% (95% CI 6.3%-17.5%) of cases for both KardiaMobile 6L and Apple Watch, 7.4% (95% CI 3.9%‐13.6%) for FibriCheck, and 14.8% (95% CI 9.5%‐22.2%) for Preventicus (P=.21). Participants preferred Apple Watch over the other devices to monitor their heart rhythm. Conclusions: In this study population, the discrimination between sinus rhythm and AF using CWDs based on ECG or PPG was highly accurate, with no significant variations in performance across the examined devices.